Get complete information related to latest Canopies Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Canopies Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Canopies Tenders.
Tender For a) scope of work covers supply, installation and commissioning of total 12 nos.of 3d radar level transmitters for the coal level measurement in raw coal bunkers of rtps-unit-5&6 with required pcs, electronic modules, splitters, modems, junction boxes, mounting kit, enclosures, interconnecting cables, software and all other accessories required to make the system complete and fully functional, shall be provided for continuous level measurement and monitoring of level of each coal bunker and also to ensure satisfactory performance of the system commissioned at rtps site which shall be on the basis of single point responsibility, completely covering the activities and services in respect of all the equipment works specified and covered under the specifications. the work involves i) installation and commissioning of 12 nos. 3d radar level type level transmitters with suitable mounting accessories, display indicators, isolators, annunciator, smps, terminals, panel internal wiring, led bulbs, door switch etc. at the bunker level ii)commissioning of rs 485 communication /other cables from bunker level transmitters to the desktop pc at u-5&6 control rooms.iii)commissioning of desktop pcs for 3d multi vision for monitoring of all the 12 bunkers level at u-5&6 control room respectively and also both units bunker levels at pc being installed at chp control room. iv)loading of all the required licenced software to the desktop pc for 3d radar level transmitter and cable routing, glanding, mounting of cable tray, termination and ferruling is in the contractors scope.cable trays will be provided by m/s.kpcl.b)all fabrication works required for installation and commissioning of instruments with jbs,protective cover/canopies and allied works are in contractor/agency scope itself.c) all civil works like drilling/cutting rcc floors,grouting,refilling floors,conduiting under ground cables cable tray mounting, masonary works are in contractor/agency scope itself.d)storage of materials while executing works is single point responsibility of contractor/agency scope itself. e)software details-1. the page containing all bunker level data shall be in full page which must be visible from at least a distance of 6-8mtr .(font size should be more) and shall have a historical trend storage for minimum 45days & real time trend with not less than15min sampling time. f) at chp control room, the existing kpcl pc shall be enabled with bunker level software & shall be communicated through existing lan and as a redundancy the seperate optical fiber cable communication with media convertor has to be provided.the lan cables has to be protected with cable conduit g)materials supply shall be completed in all respect within the stipulated period as per the contract. materials shall be delivered to rtps site through ee(stores)o&m. unloading of materials at rtps site location and shifting of the same to work location is under the contractor/agency scope only. h)handling, shifting, unpacking and erection and commissioning of the entire system shall be under the scope of bidder itself. i)all required consumables, hardware and licenced software, accessories and any other materials which are not included in the scope and required for successful installation and commissioning of the 3d radar level transmitters for the coal level measurement in raw coal bunkers of rtps-unit-5&6 are under the contractor/agency itself. j)all the materials required for the installation and commissioning of 3d radar level transmitters for the coal level measurement in raw coal bunkers of rtps-unit- 5&6 shall be made as detailed under the technical specifications. k)interfacing of all the bunker level transmitters outputs to the desktop pcs at u-5&6 control rooms through rs - 485 communication protocol.(the required 1 pair x 1 sq.mm shielded armoured cables as per requirements shall be supplied approx-500 meters or if more). for more details of scope of work refe
Tender For design, supply, fabrication, and erection of canopies with foundation, linear light fittings, roofing, false ceiling, and water drainage system with inspection chamber, hume pipe and allied works at various ros/ksks under varanasi do upso-i
Tender For provision of pol stores for microlight base elect section tool crib addn altn of roof sheet provn of view cutters and other allied work at certain location of af station under ge af bamrauli - surface dressing n exc 15 cm deep in soft/loose soil, complete all as specified and directed., excavation in trenches for n.exc 1.50m wide not exceeding 10 sqm on plan and n.exc 1.5m in depth in soft/ loose soil and getting out, complete all as specified and directed., excavating over areas hard & dense soil, n. exc 1.5 m deep and getting out, complete all as specified and directed., m&l for pcc 1:4:8 type d2 graded stone aggregate cement concrete in flooring, foundation, filling and mass, complete all as specified and directed., returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed., removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m. complete all as specified and directed., m&l for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed., m& l for rcc type b1, (1:2:4) nominal mix (20mm grade aggregate) foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, complete all as specified and directed., m&l for rcc (20mm grade aggregate type b1 (1:2:4) nominal mix columns, pillars, piers, posts and struts, complete all as specified and directed., m&l for rcc type b1, (1:2:4) nominal mix (20mm grade aggregate slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed., m&l for rcc type b1, (1:2:4) nominal mix (20mm grade aggregate) beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed., m&l for rcc type b1, (1:2:4) nominal mix (20mm grade aggregate to chajjas, complete all as specified and directed., m&l for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, complete all as specified and directed., m&l for formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and directed., m&l for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping), complete all as specified and directed., m&l for formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed., m&l for formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of rcc/pcc bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide, complete all as specified and directed., s&f for mild steel tmt bars 10mm dia and over, cut to length, bent to shape required, includingcranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed., s&f for mild steel tmt or twisted bars 6 to 8 mm dia as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia as in stirrups etc. complete all as specified and directed., m& l for pcc 75mm thick type c-1 ,1:3:6 using 20mm graded stone aggregate as in plinth protection, complete all as specified and directed., m&l for brick work with sub class b bricks, straight or curved on