Get complete information related to latest Canopy Analyzer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Canopy Analyzer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Canopy Analyzer Tenders.
Tender For rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have continuous reagent
Tender For corrigendum : supply of reagents for immunoassay siemens atellica im1600 analyzer e e -alpha fetoprotein , atpo ii , ca 125 , ca 19.9 , cea , cortisol , estradiol , ferritin , fol , psa free , fsh , ft3 , ft4 , homocysteine , pth , insulin , lh , prolactin , psa , total hcg , tsh3-ultra ii , testosterone ii , vitamin b12 , vitamin d 25-oh , troponin i high sensitivity , ntpbnp , procalcitonin- brahms , amh , pct-brahms qc kit , psa free cal 2pk , pth qc kit , t3 t4 vb12 anc rgt 6pk , thcg dil 2pk , vb12 dtt rel kit , vitd qc kit , wash 1 , atpoii dil 2pk , atpo2 qc kit , cuvettes , sample tips , apw1 2pk , acid , atellica im apw3 2pk , base , ca 125ii cal 2pk , ca 19_19 dil , cal 30 2pk , cal a2pk , cal b 2pk , cal c 2pk , cal d 2pk , cal e 2pk , cal q 2pk , cea dil 2pk , cleaner , hcy cal 2pk , hcy dil 2pk , fol dtt rel kit , insulin cal 2pk , insulin dil 2pk , multi diluent 1 2pk , multi diluent 11 2pk , multi diluent 13 2pk , multi diluent 2 2pk , multi diluent 3 2pk , atellica im multi - diluent 15 , tube top sample cups , sato t102h size 90 mm widthx100 m , amh qc , humidity pack , sp probe assay reagent