Get complete information related to latest Cantilever Rack Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cantilever Rack Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cantilever Rack Tenders.
Tender For supply of interactive display panel with inbuilt or external camera setup , open pluggable specification , display unit , ptz camera , usb video capture card , desktop computer - with all required accessories , ceiling tile microphone , dante enabled audio conferencing processor , networked loudspeaker , 8-port poe switch for audio-visual system , acoustic treatment , 24-port poe switch for network system , 12 u server rack , wireless access point , cable connector converter mounting and installation
Tender For procurement of spares for ms mekaster make rack and pinion type elevator (oem) installed at chimney for 210mw atps, mppgcl, chachai.- drive unit which includes sew (break motor sew 9.2kw, gear box 14:1 , couplings, flanges, c.f. brakes, pinion-m8, complete drive unit assy) m/s mekaster, base panel complete (with tft connection) m/s mekaster, cage panel complete (with tfr connection) m/s mekaster, safety device module - 8 for 400 kgs elevator m/s mekaster, manual break releasing system m/s mekaster, limit switch up & down - ll1 or lla with arms m/s mekaster, cage fan 220v m/s mekaster, machinery plate rubber with washer 1000 kg m/s mekaster, key switch with element m/s mekaster, drop test pb station with cable (kit) m/s mekaster, mast cable bracket m/s mekaster
Tender For bid to ras supply of camera for cctv system (v3) (q2) , video recorder for cctv system (v2) (q2) , layer 2 access switch (v2) (q2) , networking / server rack (q2)
Tender For bid to ras supply of camera for cctv system (v3),video recorder for cctv system (v2),video recorder for cctv system (v2),video recorder for cctv system (v2),layer 2 access switch (v2),networking / server rack
Tender For tender for supply of radiation resistant cctv camera : : - type-ii (color ccd/cmos , 100m rad) radiation resistant camera head along with radiation resistant pan & tilt unit and mounting brackets. as per attached annexure-1 , corrigendum annexure-2 and annexure-3. , cabling system to transmit signals form vault cameras to ccu system which includes camera to ccu radiation resistant composite cable of 300 meters with 6 sets of cable connectors and applicable power cables as per annexure-1 , corrigendum annexure-2 and annexure-3. , field camera control unit and its racking system which includes 2 no. of camera control unit sub rack & 6 sets of camera control unit (ccu) cards (3 to be installed in field and 3 to be kept as spare for future ) as per annexure-1 , corrigendum annexure-2 and annexure-3 or equivalent sub rack system as per annexure-1 , corrigendum annexure-2 and annexure-3. , setup to convert ccu signals to optical signals which should include 3 no. of fiber optic transmitter and receiver set (capable of 4 camera system) and 6 no. of fiber patch cords , single mode , simpex and 3 no. of light interface unit 12 port , as per annexure-1 , corrigendum annexure-2 and annexure-3. , type-vi (color ccd/cmos sensor , non rr auto dome camera) with mounting brackets as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism to transmit signal from non radiation resistant camera including , poe power supply for non-rr ptz camera (6 no.) field jb /rack in ss material for non-rr ptz camera (2 no.) liu 6 port , din rail mountable for non radiation resistant ptz camera (3 no.) din rail 8 port un-managed network switches (3 no.). 4 no. of fiber patch cords , single mode , duplex for non-radiation resistant ptz camera or equivalent as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism for receiving signal at control room including light interface unit 24 port , rack mount (2 no.) and network video encoder (minimum 16-channel) along with accessories for intra-panel connections (2 no.) and 24 port un-managed network switches or equivalent (2 no.) , 4 no. of fiber patch cords , single mode , duplex as per annexure-1 , corrigendum annexure-2 and annexure-3. , recording and monitoring pc as per annexure-1 , corrigendum annexure-2 and annexure-3. , joystick suitable for mounting on control room panel cutout as per panel drawing as per annexure-1 , corrigendum annexure-2 and annexure-3. , 21 inch led backlit led color monitor as per annexure-1 , corrigendum annexure-2 and annexure-3. , video monitoring software setup as per annexure-1 , corrigendum annexure-2 and annexure-3 for minimum 9 camera. , mobile dolly consisting of camera control unit (ccu) , encoder , switch , joystick , engineering laptop with 15-inch to 17-inch screen , video management software for one camera , connection cables etc and their cabling as per annexure-1 , corrigendum annexure-2 and annexure-3. , control panel/rack 42u/ 27u setup for racking all instruments of cctv at control room as per annexure-1 , corrigendum annexure-2 and annexure-3. , cabling network optical fiber cable (6 core armored cable)-2000 meters twisted pair cable , rs485 , signal cable -200 meters unarmored coaxial cable rg59 -200 meters ethernet cable , cat-6 utp cable -610 meters video connector set -10 meters ethernet connectors rj-45 100 pieces conduit for cables 800 meters and other separate cables/ power cables/accessories required during installation one set of tool tackles for assembly/ disassembly/ of radiation resistant camera head viz. allen keys , lubricants , cable ties , loctite , heat sink , blank caps etc. 2 no. of control panel/rack size 27u setup for racking all instruments of cctv at field as per annexure-1 , corrigendum annexure-2 and annexure-3. as per annexure-1 , corrigendum annexure-2 and annexure-3 . , site installation & commissioning as per annexure-1 , corrigendum annexure-2 and annexure-3. , spare radiation resistance camera head s
Tender For supply of phelotomy chairs , liquid waste management system , three bucket mop trolley system , bio-medical waste segregation trolley 4bin 16 litre , drinking water facility water purifier , 10 seater conference table with mikes and electrical points for each seat , 4 seated cubicle or 4 seated workstation with electrical points for desktop or laptops computer and printer , executive table , executive chair with wheels , computer chairs , office chairs s type with wheels , almirah cupboards to sotre the files registers and accessories , pigeon hole locker 12 compartments , storage racks rack with shelves for store room to assemble the reagents consumables , revolving stools for lab work
Tender For bid to ras supply of shoe rack , two seater sofa 5 feet , music system , seat cusion cover , operator chair cover with embroidery , normal chair cover with embroidery , window chair cover with embroidery , white board 4 x 3 feet , air purifier
Tender For supply of sailors bar at ins baaz c c - plaster of paris , painting of wall , electrical work , window curtain , split ac , round table , chair , bar counter and rack , beer glass , bar glass , beverage cooler , deep fridge , music system , led tv
Tender For supply of 48 core unarmoured ofc , plb 32 by 26 mm hdpe pipe wall thickness 3 mm , excavation trenching digging 1.6 meter depth and laying of ofc including splicing at each joint and drops and back filling as per standard , trenching by hdd railway track and roads , right of way row , laying of hdpe pipe including ofc laying and jointing enclosures as per requirement , 48 core fiber joint enclosures , joint chambers or manholes 1 mtr x 1 mtr rcc ring type with cemented base , route marker of 3.5 feet long with engraved marking and 1.5 feet underground in cement base , ofc warning - caution tape , 48 port lc-lc fdf with side mounting and sliding feature and termination of ofc in fdf , tjb metal with wall mounting fitting and accessories , lc- lc duplex patch cords 1 mtrs , lc-lc duplex patch cords 3 mtrs , media converter fibre to rj-45 with power adapter , 15 u l2 rack glass door and locking facility with installation of rack on wall with installed spike buster of 5 socket 16- amp socket and 5 meter power cord , iron bar to be fixed on the wall for l-2 switch rack , cable tray metallic for routing of ofc and cat-vi cable up to l-2 rack , cable manager , patch panel 24 port cat-vi , industrial grid socket , ac spd , chemical earth pit en voltage should be less than 2 volt and earth resistance less than 3 ohms , eearth strip copper from earth pit to l-2 rack , 1 kva ups with online parameter monitoring system , battery bank 12 volt 42 ah