Get complete information related to latest Capacitor Bank Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Capacitor Bank Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Capacitor Bank Panel Tenders.
Tender For series reactor for capacitorbank low loss with suitable for 5500kvar at 40kv as per rdso spec no. ti/spc/psi/fc&sr/0100 (01/10) with slip no.1 or latest including mounting structure. all technical details/drawing should be along with offer. warrantyperiod: 30 month(s) from the date of supply. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply ,erection ,testing & commissioning of control & relay panel for split capacitorbankpanel with numerical protective relays as per rdso specification no. ti/spc/psi/protct/6072 with a & c slip no.1 or latest. [ warranty period: 30 months after thedate of delivery ] ]
Tender For supply of 3 kvar metalized polypropylene gas filled, wavy cut three phase self healing type capacitors,rated at 480v, 50hz , rated current 3.6 amps capacitor should have discharge resistor and over pressuredisconnection as per rdso modification sheet no. rdso/pe/ms/ac/0054-2014 rev-1 and confirming to is13340(part-1) 2012/iec 60832-12002 with isi mark suitable for capacitorbank of lhb ac coach,acceptablemakes epcos or vishay or any other equivalent capacitor confirming to is13340 with isi mark. [ warrantyperiod 30 months after the date of delivery [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For appointment of contractor/bidder for supply of material, erection, testing & commissioning for augmentation of 72 nos. existing 33 kv sub-stations (including civil work as per site requirements) on turnkey basis under revamped reforms-based and results-linked distribution scheme- 33/11 kv s/stn. items , 12.5 mva threee phase 50 hz, 33/11 kv step down outdoor onan power transformer complete with all accessories/fittings and conforming to latest nigam's technical specification with amendments relevant iss with latest amendments., , 33kv l & e switch (630amps), , 33kv isolators (630 amps), , 33 kv vcb, 36 kv, 1250a with 1000 mva (16 ka for 1 second) rupturing capacity vcb for out door use conforming to latest nigam's technical specification no. csc-24/r-ii/uh/dh/p&d/2020-21 with relevant iss & latest amendments thereof., , 33 kv c&r panel 24 v dc operated suitable for controlling one t/fs (with differential protection) as per nigam's tech. spec., relevant iss and latest amendments., , 33kv lightening arrestor sub-stn type 30kv 10ka with surge counter., , 33kv cts 600/300/5-5-5-5 with junction box, , 33kv pts with junction box, , 33kv post insulators, , disc fitting t&c type, , 11 kv vcb rating 1250 amp. 25 ka, 475 mva rupturing capacity 24v dc operated for incoming panel i/d type, , 11 kv vcb rating 400 amp. 25 ka, 475 mva rupturing capacity 24v dc operated for outgoing panel i/d type, , 11 kv vcb rating 400 amp. 25 ka, 475 mva rupturing capacity 24v dc operated for capacitorpanel i/d type, , 11kv lightening arrestor sub-stn type 9 kv 10ka (heavy duty), , 11kv ncts 900/5a, , 11 kv automatically switched capacitor apfc capacitors panal 4.8 mvar complete (with l&e switch, structure and all allied material as per nigam's tech. spec., relevant iss and latest amendments, , structure for 33 kv cts (galvanized) wt. 87.62 kg., , structure for 33 kv pts (galvanized) wt. 87.62 kg., , structure for 33 kv la (galvanized) wt. 76.38 kg., , structure for 33 kv post insulators (galvanized) wt. 76.38 kg, , structure for 33 kv isolator (galvanized) wt.288.36 kg., , structure for l&e switch (galvanized) wt.288.36 kg., , structure for 11 kv nct (galvanized) wt.92.37 kg., , structure for cable stand, , gantry tower-2xdb-2, 2xdt-2, 2xdt-3 per sub-station, , structure for 11kv la/cable stand, , acsr conductor 80 sq mm(raccoon), , acsr conductor 0.2 sq in(panther), , 11kv single core xlpe cable 630mm², , 11 kv outdoor cable boxes for s/c 630 sq mm cable, , 11 kv indoor cable boxes for s/c 630 sq mm cable, , 11 kv xlpe cable 3 c x 300 sq. mm for capacitorbank, , 11 kv outdoor cable boxes for 3c x 300 sq mm cable, 11 kv indoor cable boxes for 3c x 300 sq mm cable, gi channel 100x50x6mm (gi) various size, gi angle iron 50 x 50 x 6 mm (gi) various size, gi flat 50 x 6 mm, gi flat 75 x 8 mm for earth mat in switchyard, earthing of s/stn. with pipe & earthing plate complete with machnary chamber, g.i pipe 40 mm dia 6 mtr. long for earthing set b class, premier synthetic insulating mat (class-b as per isi 15652:2006), pg clamps for panther conductor, gi nut & bolt off size, flood light led 240 watt (ip-67 rating), aluminium die cast body (make-, crompton, bajaj, phillips and havells only), 11 meters long pcc poles, un armoured copper control cable 2c x 6mm2, un armoured copper control cable 2c x 4mm2, un armoured copper control cable 7c x 2.5mm2, un armoured copper control cable 10c x 2.5mm2, un armoured copper control cable 3c x 4mm2, un armoured copper control cable 4c x 4mm2, un armoured copper control cable 6c x 4mm2, c-wedge connector for 0.2 sq. inch. panther conductor (nom. ai area, 200mm2), 33 kv polymeric disc insulators 70/90 kn b & s type, single tension fitting for 0.2 inch2 /150 mm2 acsr conductor, wooden cleat, ni-cd alkaline battery capacity (100ah) with static battery charger as, per nigam's specification., dry chemical type fire extinguisher (5 kgs), co2 type fire extinguisher (10 kgs), dry chemica
Tender For supply of 3 kvar metalized polypropylene, nitrogen gas filled, wavy-cut, 3 phase, self healing type capacitors rated at 480v, 50 hz. capacitor should have discharge resistor and over pressure disconnection as per rdso modification sheet no. rdso/pe/ms/ ac/0054-2011 (rev-0) and confirming to is: 13340, suitable for capacitorbank for lhb type (eog ac coaches/power car/eog gs ac coaches and double decker ac eog coaches.) (make and model should be m/s epcos part no. b25671r4032a 80 and m/s vishay part no. acmkphd480.3.3.00 or any other rdso approved make confirming to is: 13340 with isi mark and having properties as defined in table-1 as per rdso modification sheet no. rdso/pe/ms/ac/0054-2011 (rev-0) and confirming to rcf edml-130 (rev-1) corrigendum 1 to 7. firm shall submit complete type test report as per is:13340 along with latest isi certification. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : enquiry for supply of various items for stm offices situated under gm (o and m) mpmkvvcl vidisha. - ac coil capacitorbank switch cantrol coilmodule for capacitor switch
Tender For increasing capacity from 1x40+1x20 mva to 1x63+1x40 mva & replacement of 33 kv 2x5 mvar capacitorbank at 132 kv s/s, baghauli under etd hardoi
Tender For supply of 3 kvar metalized polypropylene, gas filled, wavy-cut, 3 phase self-healing type capacitors rated at 480v, 50hz. capacitor should have discharge resistors and over pressure disconnection as per rdso modification sheet no. rdso/pe/ms/ac/0054-2011 rev-1 and confirming to is:13340 (part-1) :2021/iec 60832-1:2002 with isi mark suitable for capacitorbank of lhb ac coaches. make m/s epcos & m/s vishay or any other equivalent capacitor confirming to is:13340 with isi marked and having properties as defined in table-1 in rdso modification sheet. firm shall submit complete type test report for capacity 3 kvar or higher as per is: 13340 along with latest isi certification with prior approval of rdso [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of 1 kvar metalized polypropylene, gas filled, wavy-cut, 3 phase self-healing type capacitors rated at 480v, 50hz. capacitor should have discharge resistors and over pressure disconnection as per rdso modification sheet no. rdso/pe/ms/ac/0054-2011 rev-1 and confirming to is:13340 (part-1) :2021/iec 60832-1:2002 with isi mark suitable for capacitorbank of lhb ac coaches. make m/s epcos & m/s vishay or any other equivalent capacitor confirming to is:13340 with isi marked and having properties as defined in table-1 in rdso modification sheet. firm shall submit complete type test report for capacity 1 kvar or higher as per is: 13340 along with latest isi certification with prior approval of rdso [ warranty period: 30 months after the date of delivery ] ]