Web Analytics Made Easy - StatCounter

Capacitor Bank Tenders

Get complete information related to latest Capacitor Bank Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Capacitor Bank Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Capacitor Bank Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45737465 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For supply of 3 kvar metallized polypropylene gas-filled, wavy cut, three-phase, self-healing type capacitors, rated at 480v, 50 hz, rated current 3.6 amps, diameter size 2". capacitor should have discharge resistor and over pressure disconnection, as per rdso modification sheet no. rdso/pe/ms/ac/0054-2011 rev.-0 or latest, and conforming to is:13340with isi mark. suitable for use in capacitor banks of lhb ac coaches. make: epcos. type: phicap, cat no. b25671r4032a080, and m/s vishay or any other make conforming to is:13340with isi mark and having properties as defined in table-1 of rdso modification sheet no.rdso/pe/ms/ac/0054-2011 (rev.-0). [ warranty period: 30 months after the date of delivery ] ]

Central Government And Public Sector

CTN :45741385 Due date: 23 Jul, 202623 Jul, 2026 NA
Tender For comprehensive annual maintenance contract of control & relay panel incorporating numerical relays for 25 kv ac tss and shunt capacitor bank for 01 (one) no. of tss for a period of 05 (five) years.

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

Central Government / Public Sector

CTN :45731751 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For supply of kvar metalized polypropylene gas filled, wavy cut three phase self healing type capacitors, rated at 480v, 50hz , rated current 3.6 amps capacitor should have discharge resistor-e and over pressure disconnection as per rdso modification sheet no. rdso/pe/ms/ac/0054-2014 rev-0 and confirming to is: 13340(part-1) : 2012/iec 60832-1:2002 with isi mark. suitable for capacitor bank of lhb ac coach. acceptable makes: epcos or vishay or any other equivalent capacitor confirming to is:13340with isi mark. [ warranty period: 30 months after the date of delivery ] ]

corporations/Associations/Others

CTN :45734466 Due date: 10 Jul, 202610 Jul, 2026 2.97 Lacs
Tender For restoration and strengthening of capacitor bank system for 6 nos motor feeder at raw water ph iii of grww

State Government

CTN :45743605 Due date: 18 Jul, 202618 Jul, 2026 2.44 Lacs
Tender For erection work installation of 36kv 12 mvar capacitor bank and other associated works at nimrani 220kv substation

corporations/Associations/Others

CTN :45729980 Due date: 17 Jul, 202617 Jul, 2026 NA
Tender For replacement of faulty parts/accessories and upgradation of 100 nos. existing 1.98 mvar (3-step) apfc capacitor bank systems to 4.356 mvar installed / 3.96 mvar effective (5-step heterogeneous) apfc systems at 33/11 kv sub-stations

corporations/Associations/Others

CTN :45346551 Due date: 09 Jul, 202609 Jul, 2026 2.27 Lacs
Tender For corrigendum : special estimate for erection of 33 kv capacitor bank of capacity 10.872mvar with allied equipment on 40/50 mva 132/33 kv t/f t- 3 at 132 kv s/stn.hvpnl miran

CTN :45744304 Due date: 07 Jul, 202607 Jul, 2026 1.25 Lacs
Tender For providing &amp fixing of lighting fixtures for new 33 kv capacitor bank bay at 132 kv gss raithal, distt- bundi
 Loading, Please wait...

Connect us via What's Up