Get complete information related to latest Cbr Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cbr Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cbr Machine Tenders.
Tender For supply, termination installation, testing and commissioning of ventilation system in paint shop of lower parel workshop along with complete installation of industrial air blower with movable trolley, operating voltage 190v ac to 380 v ac, 50 hz, single/three phase supply, maximum power consumption shall be less than 600 watt, maximum speed of 400 rpm, air flow of 700 meter cube per minute, weight shallbe less than 60 kg and noise shall be less than 50db. size of blower shall not be more than 1500 mm diameter confirming to is 6272-1987 or latest all electrical works shall be carried out in accordance with the provision of indian electricity act 2003 and indian electricity rules 1956 amended to date and all the safety codes and procedures outlined in the safety codes shall be complied with general and safety requirement shall be governed by is 13947 (pt 1) 1993 and is:8623/1993, amended to date. termination of all cables shall be done with bimetallic terminal connector suitable for 2.5 dia aluminium tubular busbar for 20a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 2.5 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. materiat shall be confirmed to designation a6 of is: 617-1959. breaking resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 2.5. type test certificate from nabl or any other govt. agency lab report shall be attached along with the offer without which offer will be rejected. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply & testing of 4 core, 120 sq mm, lt power al cable, xlpe insulated, cores laid up, pvcinnersheathed, armoured aluminium stranded conductor, extruded pvc type st2 outer sheathed, 650/1100 v grade as per is 7098 (part 1) 1988 or latest as per instruction of engineer incharge at site. [ warrantyperiod: 30 months after the date of delivery ] ]
Tender For supply & testing of 4 core, 185 sq mm, lt power al cable, xlpe insulated, cores laid up, pvcinnersheathed, armoured aluminium stranded conductor, extruded pvc type st2 outer sheathed, 650/1100 v grade as per is 7098 (part 1) 1988 or latest as per instruction of engineer incharge at site. [ warrantyperiod: 30 months after the date of delivery ] ]
Tender For supply & testing of 4 core, 185 sq mm, lt power al cable, xlpe insulated, cores laid up, pvcinnersheathed, armoured aluminium stranded conductor, extruded pvc type st2 outer sheathed, 650/1100 v grade as per is 7098 (part 1) 1988 or latest as per instruction of engineer incharge at site. [ warrantyperiod: 30 months after the date of delivery ] ]
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc
Tender For repairs maintenance of electrical and mechanical equipments high mast light search lights and other miscellaneous items at cad pulgaon - disconnecting and taking down existing unserviceable street lights/flood lights any type/watts from pole/wall and dismantling the light fittings. repairing/replacing unserviceable parts re-fixing the same on pole/wall after testing and removal of carbon from line jumpers/tightening of jumper/alignment of fitting defective street light/security light/flood lights fitting/led light from electric pole complete all as directed by eic. note: spare parts and accessories such as led driver, and connected items etc will be measured and paid separately under respective item as supply only and fixing is deemed to be included in this item., supply only led street light driver for 45 watts led street light as per make given all as specified and directed by eic., supply only led street light driver for 60 watts led street light/ flood light type as per make given all as specified and directed by eic., supply only led street light driver for 100 watts led street light/ flood light type as per make given all as specified and directed by eic., supply and fix in repair led streetlight of 45 watt comprises of pressure die cast aluminium housing & having system efficiency>123 lumens/watt i.e 5570 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k,pf>0.9,driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account. 3.the complete fitting along with led module, driver, surge protection device and all associated accessories shall be covered under 05 (five) years comprehensive warranty by the contractor from the date of invoice.make : philips/ wipro/crompton, supply and fix in repair led streetlight of 60 watt comprises of pressure die cast aluminium housing & having system efficiency>110 lumens/watt i.e 6670 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k, pf>0.9, driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic. note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account.3. the complete fitting along with led module, driver, surge protection device and all as
Tender For supply, installation and commissioning of pre-wired modular workstation consisting of a single control office customized to equip two sads and two daws systems arranged and installed on a t-shaped modular workstation with integrated cable management systems as per specifications. specifications of modular workstation: 1) the workstation shall each be of 5 feet (l) x5 feet (w) the combined size: 10 feet (l) x 5 feet (w) - 1set, made of 25 mm nfc wood and 1 mm acrylic laminate. 2) the sads displays shall be installed such that the bottom edge of the display is at a height of 5' (approximate) from the floor. these shall be installed preferably along the longer edge of the t and facing the operators, 3) the daws system shall be installed such that it is possible to be used sitting at the workstation. 4) all interconnecting wiring for lan, power supply and telephones shall be done inside the cable management system (powder coated aluminium interlocking extrusions) and adequate ports shall be provided on the work surface. communication accessories: i) lan rj45: 4 nos ii)telephone, rj11 : 4 nos iii) power supply, 5 amp sockets: 6 nos 5) all wires shall be brought out to interface boxes one for power supply and another for the communications cables. these boxes shall be designed to accept connections from the control room circuits. note: design, supply, fitment, installation, testing and commissioning shall have to done by the firm confirming to the pre-wired modular t- shaped workstation standards. material shall confirm to hpl/nfc engineered wood (25mm thickness) as per epd-ies-0012055:002 (s-p- 12055) certification. make: godrej interio/tumbi/greeken/moudulartek or its equivalent. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply and installation of bbt from ha substation to materials movement area - design, manufacture and supply of sandwiched aluminium bus-bar trunking system 2000a capacity with canopy and all other accessories for successful installation work from ha substation to material movement area as per attached scope of work and technical specification., installation, testing and commissioning of sandwiched aluminium bus-bar trunking system 2000a capacity with canopy and all other accessories for successful installation work from ha substation to material movement area as per attached scope of work and technical specification., supply of 400a tap-off box with complete accessories as per attached scope of work and technical specification complete., installation of 400a tap-off box with complete accessories as per attached scope of work and technical specification complete., supply of 25x6mm copper strip, installation of 25x6mm copper strip, fabrication and supply of switchboard for 3phase 415v ac 50 hz system with incomer - 400a mccb 1 no, outgoings - 400a mccb 1 no, 200a mccb - 1no, 125a mccb - 1 no, 63amccb - 3nos and all accessories as per technical specification and scope of work, installation of switchboard for 3phase 415v ac 50 hz system with incomer - 400a mccb 1 no, outgoings - 400a mccb 1 no, 200a mccb - 1no, 125a mccb - 2 no, 63amccb - 2nos and all accessories as per technical specification and scope of work, supply of 3.5cx150sqmm a2xfy cable, installation of 3.5cx150sqmm a2xfy cable, supply of glanding and termination of 3.5cx150sqmm a2xfy cable, glanding and termination of 3.5cx150sqmm a2xfy cable, installation of 25x3mm copper strip