Get complete information related to latest Cement Tank Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cement Tank Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cement Tank Tenders.
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For auction sale of depot ferrous scrap - stainless steel scrap consist of cond. unserviceable various types of water tanks in different shap, size and capacity. sr. no. 1- auxiliary water tanks cap. appox 30 ltr = 188 nos. (09 nos. in cylendrical shape, 24 nos. triangular cylendrical shape & 155 nos. rectegular cylendrical shape), sr. no. 2- chamfered rectangular size water tank = 26 nos., sr. no. 3- twin set type trapezoidal prism shape water tank qty. =34 nos. released from coaches, with ferrous and rubber attachment, complete/incomplete, with or without negligible nf attachment, as is where basis, unfit for railway use, lying in plot no. 1 [gst 18% hsn 720421]delivery will be given in following order :- sr. no. 1- auxiliary water tanks cap. appox 30 ltr = 188 nos. (09 nos. in cylendrical shape, 24 nos. triangular cylendrical shape & 155 nos. rectegular cylendrical shape), sr. no. 2- chamfered rectangular size water tank = 26 nos., sr. no. 3- twin set type trapezoidal prism shape water tank qty. =34 nos. respectively.
Tender For providing of repair and overhauling service - mt spares 09 lines; switch combination, brake fluid container, low pressure switch, air distributor and, dryer unit, water manifold pipe, auxiliary water tank, radiator hose set, bush kit, pipe flexible 1/2"
Tender For supply of auxiliary roof water tank for ac coaches with roof mounted ac package unit to drg.no. icf/sk-6-3-446,alt. no.-e. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For auction sale of rolling stock - pl no.98111061, condemned and over aged bg-8 wheeler icf coach 2 nos. with all available ferrous non-ferrous wooden fittings thereon but excluding the following rc items. 1}coach no. special repair cn 046245 (year built 2004), ds-8 no. 334714 dt 31.03.26, mechanical rc items as per sse/c&w/srr letter no.s-98/coach condemnation/rc items dt.04-11-2025 , coach no.srcn 046245 1] complete bogie arrangements including wheel sets 2 nos, 2] buffer plunger and casing 4 nos 3] cbc/screw coupling set [draw bar with hook, draft gear assembly] 2 set, 4] center pivot 2 nos. 5] bogie mounted brake cylinder 4 nos, 6] distributer valve complete full set 1 set, 7] wearing piece( bronze) and plate 4 nos each, 8] auxiliary reservoir 200 l. 1 no 9] main doors -4 nos 10] water tank-4 nos 11] cut off angle cock -4 nos 12] dirt collector- 2 nos 13] non return valve(fp)- 1 no, electrical rc items as per sse/electrical/srr letter no.elg/srr/6a dt.09.09.25. 1] bldc fan 400 mm-27 nos. 2]9w led lamp-26 nos. 3]2w lamp -8 nos 4]eml- 4 nos 5]mobile charger socket-18 nos. 6] regulator 4.5 kw- 1 no 7]vrla battery with tray-19 nos. 8] battery tray- 4 nos.9] rotary switch with panel board- 1 no 10] alternator to regulator wire ( copper ) -1 kg 11] one alternator(4.5 kw) & one set of axle pulley ( with bogie), 2} coach no. special repair cn 046213, (year built 2004) ds-8 no. 334715 dt 31.03.26, mechanical rc items as per sse/c&w/srr letter no.s-98/coach condemnation/rc items dt.04-11-2025 , coach no.srcn 046213 1] complete bogie arrangements including wheel sets 2 nos, 2] buffer plunger and casing 4 nos 3] cbc/screw coupling complete set [draw bar with hook, draft gear assembly] 2 set, 4] bogie mounted brake cylinders- 4 nos 5] distributer valve complete full set 1 set, 6] wearing piece( bronze) and plate 4 nos each, 7] auxiliary reservoir 200 l. 1 no 8] main doors -4 nos 9] water tank-4 nos 10] cut off angle cock -4 nos 11] dirt collector- 2 nos 12] non return valve(fp)- 1 no, electrical rc items as per sse/electrical/srr letter no.elg/srr/6a dt.25.07.25. 1] bldc fan 400 mm-27 nos. 2]9w led lamp-26 nos. 3]2w lamp -8 nos 4]5w westibal 2 nos 5]eml- 4 nos 6]mobile charger socket-18 nos. 7] regulator 4.5 kw- 1 no 8]vrla battery with tray-19 nos. 9] battery tray- 4 nos.10] rotary switch with panel board- 1 no 11] alternator to regulator wire ( copper ) -1 kg, custodian sse/ c&w/ shoranur.
Tender For provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti
Tender For corrigendum : supply of auxiliary roof water tank for ac coaches with roof mounted ac package unit to drg.no. icf/sk-6-3-446,alt. no.-e. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]