Web Analytics Made Easy - StatCounter

Centralizer Tenders

Get complete information related to latest Centralizer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Centralizer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Centralizer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

CTN :45703487 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For tender for repair and refurbishment of greasing system pressure generation and distribution solenoid valve

corporations/Associations/Others

CTN :45449568 Due date: 03 Jul, 202603 Jul, 2026 4.41 Lacs
Tender For corrigendum : supply of feeder and inlet gate of coal feeder for cmms 1 to 6 mtps - fdr , weldment , flap , feeder side door gasket , fitting type-4 feeder greasing system , fitting type- 3for feeder greasing system , fitting type-2for feeder greasing system , fittings type-1

CTN :45673335 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For supply of centralizer clutch disc , cover assy 1 75 inch spline dia , feed pump , clutch cable assy , self starter assy , alternator , relay 24v , relay assy , assy universal joint , double lever combination switch , 2 pole isolator switch , dual brake valve , alternator assy

State Government

CTN :45676035 Due date: 02 Jul, 202602 Jul, 2026 12.10 Lacs
Tender For annual maintenance work of fire fighting system and refilling of existing fire extinguishers, supplying of neccessary fire fighting materials and other allied works in lok bhavan premises, bengaluru (from 01-08-2026 to 31-07-2027)- item description: engaging of mechanic-i. the work is to be carries out as per the directions of the engineer -in-charge of the work -notification no. kae 83 lmw 2022 dated 13-01-2023 , item description: providing oiling, gland packing, greasing, replacing damaged rubber gaskets using cotton waste clothes to maintain pumps, motors and fire equipments complete, including cost of all materials, labour charges, with all lead and lift, loading and unloading, transportation, machineries and all other incidental charges for successful completion of the work as per directions of the engineer-in-charge of the work. (se office letter 2184, dated 20.02.2025, sl.no 4) , item description: refilling of existing fire extinguisher for abc powder based map50, 4kg. there filling rate shall include costo fall lead and lifts, transportation, loading, unloading, fixing and all other incidental charges etc. complete asper specification and directions of the engineer in charge of the work.. (sr 23-24, sl no 15.166, pg no 100,vol -6) , item description: refilling of existing fire extinguisher for abc powder based map50, 2kg. there filling rate shall include costo fall lead and lifts, transportation, loading, unloading, fixing and all other incidental charges etc. complete asper specification and directions of the engineer in charge of the work. (sr 23-24, sl no 15.165, pg no 100,vol -6) , item description: refilling of existing c02 wheel type fire extinguisher 4.5kg. the refilling rate shall include cost of all lead and lifts, transportation, loading, unloading, fixing and all other incidental charges etc. complete as per specification and directions of the engineer in charge of the work.. (sr 23-24, sl no 15.192, pg no 103,vol -6) , item description: refilling of existing c02 squeeze grip fire extinguisher 2kg. the refilling rate shall include cost of all lead and lifts, transportation, loading, unloading, fixing and all other incidental charges etc. complete as per specification and directions of the engineer in charge of the work.. (sr 23-24, sl no 15.191, pg no 103,vol -6) , item description: refilling of existing c02 wheel type fire extinguisher 22.5kg.there filling rate shall include cost of all lead and lifts, transportation, loading, unloading, fixing and all other incidental charges etc. complete as per specification and directions of the engineer in charge of the work.. (sr 23-24, sl no 15.195, pg no 103,vol -6) , item description: refilling of existing fire extinguisher for abc powder based map90, 25kg.the refilling rate shall include cost of all lead and lifts, transportation, loading, unloading,fixing and all other incidental charges etc.complete as per specification and directions of the engineer in charge of the work.(sr 23-24, sl no 15.195, pg no 103,vol -6) , item description: supplying of hand gloves. complete. (15.113, vide (2023-24) sr, vol-6 , item description: supplying of first aid box. complete (pwd sr 2023-24, i.no. 15.114, vol-6) , item description: supplying of safety mask. complete (pwd sr 2023-24, i.no. 15.115, vol-6) , item description: providing brass polish for hydrant valves including cleaning, and two coats using upto 50ml polishing liquid to the valves, complete, including cost of all materials, labour charges, with unloading, transportation, machineries all lead and lift, loading and and all other incidental charges for successful completion of the work as per specification and directions of the engineer in charge of the work.(se office letter 2184, dated 20.02.2025,,sl.no 9) , item description: scrubbing, removing and applying of one coat of red oxide primer and final two coats of signal red paint on existing gi pipes 100mm nominal bore etc.,complete with all leads and lifts as per spe

CTN :45641093 Due date: 13 Jul, 202613 Jul, 2026 50.00 Lacs
Tender For e-tender for ortho implants - cemented thr-cement restrictor ,stem centralizer cemented thr-acetabular cup (highly cross linked,all size) cemented thr-bone cement 40gm cemented thr-femoral head (all size & offsets-28mm,32mm,36mm) uncemented thr-femoral component all offsets ,metallurgy:hyroxyapatite coating uncemented thr-acetabular component ( various hole combinations ,different shape & size,hemispherical oblong,peripheral fit ) uncemented thr-screw for acetabular fixation uncemented thr-uncemented cup uncemented thr-acetubular liner(highly cross linked) uncemented thr-femoral head (all size & offsets-28mm,32mm,36mm) tkr-bone cement 40gm tkr-femoral component tkr-tibial component (all type, posterior stablized ,pcl sparing ,constrain & semi-constrain) tkr-highly cross linked polyethylene insert revison tkr-femoral component with extension rod revison tkr-tibial component (all types as discribed earliar revison tkr-tibial extension rod revison tkr-articulated antibiotic cement spacer(femur & tibia) revison tkr-roatating hinged knee system revison tkr-bone cement 40gm acl & pcl reconstruction-endobutton(fixed loop & variable loop) acl & pcl reconstruction-interferential screw (meta & biodegradble) acl & pcl reconstruction-washer acl & pcl reconstruction-nitinol guide wire acl & pcl reconstruction-bone staple modular bipolar femur prosthesis (cemented & uncemented) bone cement 40gm with & with antibiotic shoulder rotator cuff - suture anchor (single loaded for single & double row) shoulder rotator cuff - arthroscopic cannula shoulder rotator cuff - suture anchors with suture passor(all angles,chia wire) & set meniscus repair - burr meniscus repair - shaver meniscus repair - all inside & meniscus suture ultrabraid /fiber wire suture (all size) antibiotic bone cement 40gm (all sizes) bone cement 40gm (all sizes) pulse lavage (all sizes) semi tubular, one third tubular plate (all sizes)ss& titanium 3.5mm dcp , lcdcp,lcp,recon with& without locking (all sizes)ss/titanium 4.5mm lcp narrow ,4.5mm lcp broad (all sizes) ss/titanium dhs plate locking /withlocking & standard,short barrel dcs plate (all sizes) tsp for dhs plate richard screw (all sizes) proximal femur locking plate (all size left& right if any) distal femur plate lcp (left & right all sizes) osteotomy plate 120* all sizes femur interlocking nail with locking bolt (all sizes) pfn small & long (all sizes with screws) pfan (all sizes with screws) distal femur nail (all sizes with screws) k-wire 1.0mm ,1.5mm,2.0mm,2.5mm,3.0mm (titanium) steinman pin ,denham pin ss wire 16g,18g,20g 3.5mm cortical screw (all sizes) 3.5mm locking screw (all sizes) 4.5mm cortical screw (all sizes) 4.5mm locking screw (all sizes) 6.5mm canulated screw (all size) (titanium) 6.5mm leg screw partialy,fully threaded (all sizes with washers) herbert (headless) screw (all size) (titanium) 4.0mm canulated screw (all size with washer partially threaded 16mm/32mm) small t plate ,l plate , varing angle distal radius plate all size with screw left & right if any tens nail (all size) rush nail , endrs nail (all size) k nail (all size) square nail for rdius & ulna malleolar screw 4.5mm (all size) clavicle plate 3.5mm (all sizes with screw) clavicle hook plate ,lateral end clavicle lcp (all size with scre) philos (all sizes with screws) humerus nail (all sizes with locking bolt) hockey plate (all sizes both sided with screws) proximal tibia raft plate (all sizes both sided with screws) recon plate for palvis both sided all sizes with screws proximal tibia t plate locking & non-locking (all sizes both sided with screws) proximal tibia l plate locking & non-locking (all sizes both sided with screws) distal tibia metaphyseal plate (all sizes with screws both sided) distal tibia anterolateral plate (all sizes with screws both sided) distal humerus lateral column locking plate both sided (all sizes with screws

State Government

CTN :45573613 Due date: 29 Jun, 202629 Jun, 2026 53.0 Thousand
Tender For oiling and greasing of regulators, sluice gates of system under water resources sub division bharatpur year 2026-27

State Government

CTN :45573618 Due date: 29 Jun, 202629 Jun, 2026 76.0 Thousand
Tender For oiling and greasing of regulators, sluice gates system under water resources cfc sub division bharatpur for year 2026-2027

CTN :45582371 Due date: 29 Jun, 202629 Jun, 2026 76.0 Thousand
Tender For oiling and greasing of regulators/sluice gates system under water resources cfc sub division bharatpur for year 2026-2027
 Loading, Please wait...

Connect us via What's Up