Get complete information related to latest Centrifugal Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Centrifugal Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Centrifugal Machine Tenders.
Tender For fabrication work d d - places , replacing wornout runner base and installing a new runner base of cane carrier and baggage elevator and r b c , replacing wornout runner with new one of cane carrier and baggage elevator and r b c , removing wornout angle iron and t iron of the cane carrier and reinstalling it by straightening the crooked part , removing the wornout part of the suit from different places and fitting it with new one , chevron grooving of new rollers of the mill , chevron grooving of old rollers of the mill , remove the wornout partition plates of the juice box above and below the juice heater by 10 or 12 mm ms plate and install it , installing ribs at the top and bottom partitions of the juice heater , repairing save all of qurdbody , removing old wornout gutters installed at various places and installing it with new gutters , remove the old wornout save all from pan and quard and install it with new one , reinstalling the new umbrella fitted inside the pan by making a new one and removing the old one , replacement ribbon arm of the mascute receiving crystallizer , making new separator of a centrifugalmachine , removing the wornout truff of the hopper and installing it with new one , making and installing new separators for continuous centrifugalmachines , removing the tubes of quad juice heater and dynamic juice heater and expanding them by installing new tubes and giving their hydraulic testing satisfactory of size 42 mm , removing the tubes of pan installing new tubes and expanding them and giving hydraulic tesing with satisfactory trial of size 96 mm , removing the wornout flue gas ducting of both the boilers and installing it with newone making from new or old plates , removing the wornout front and roof plate at boiler number 1 and 2 and installing with a new plate , removing the damaged boiler damper and installing a new one , making bagasse suit and installing. , replacement of juice over flow box of clarifier , making and installing bed of motor and pumps at various places as per requirement , replacement 6 inch dia cooling pipe of sulfur furnace , removing the monitor casing of a machine from old machine and installing it and giving its a trial , making amd replacing manholes at various places , making and replacing the enternals of cather of the pan. , making and replacing the new hood of cane cutter , removing the old bottom plate of the lowest compartment of the clarifier and placing a new plate on it after placing an angle trap as per the instructions and giving a satisfactory water trial , reinstalling the stirrer of the clarifier and giving a satisfactory trial , removing the shaft of a pug mill and replacing the old bushes on both sides and fitting new ones , removing and refitting the shaft of a brown sugar magma mixer and installing with new bush , reinstalling the trufff of connecting rod of the hopper , making and installing new catcher strainer , removing the old rail line of the trolley of the unloader and fitting the new rail line satisfactorily and doing water level , reinstalling the old rail line of the unloader s bridge and fitting it and checking water level etc , removal of old and weak channels of 3 inches to 10 inches diameter installed at various places and installation of new ones as per requirement , cutting and straightening old plates installed at various places as per requirement , removal of old and wornout scrubber installed on sulfur furnace and making and replacing with 8 or 10 mm plate and making all the connections , removing the trufff plate including support corroded shell and top cover plate of the top chamber of the clarifier and fitting the new plate and giving it s a water proof trial , re-installation alignment and //bid details 2 / 47 trial of hopper driving end , making and installing the top cover of the centrifugalmachine , making an arm and installing it on the shaft of pug mill , making and installing scrubber and bottle jackets of sulfur furnace , makin
Tender For corrigendum : tender for the supply of various equipments required for upgradation of district food laborartory, karnal - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles", karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard", refrigerated centrifuge (bench top),, bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples.", gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25µm (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25µm),", "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 µl recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water.", ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubing’s, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 µl, 20 µl, 50 µl, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each ofc8 = 250 × 4.6 × 5μm c18 = 250 × 4.6 × 5μmcyano = 250 × 4.6 ×5μm. amino = 250 × 4.6 × 5μmphenyl = 250 × 4.6 ×5μm. silica = 250 × 4.6 × 5μm.all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", ft-ir with atr & liquid cell, "• hydraulic press with kbr die and pellet holder• suitable mortar pestle (dia 5-6 cm)• suitable portable de humidifier to maintain 30- 60% rh• temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab.• ref