Tender For extension of last date of submission - supply, installation, testing and commissioning of diesel engine driven fire pump system at rbi main office building, jammu
Tender For supply of hydraulic diesel power pack technical specification as under (1) type of prime mover- dieselengine (2) engine hp & make - 7.5 kw/ 10 hp, greaves/ lumbardini or equivalent (3) pump capacity 5.4 lpm approx, at 450-500 bar pressure (4) oil flow option- positive displacement (5) weight -125 kg approx. (6) dimensions- 1200 x750 x 700 mm approx. (7) max. pressure 500 bar. (8) operating pressure 350-500 (9) fuel tank capacity- 5 ltr. (10) type of cooling - air cooled (11) hydraulic oil tank capacity 10-12 ltr. (12) dimension & length details of hydraulic hoses - 1d 1/4" x 10 mtr. long (13) details of end connection- male stud coupling (14) pressure up to which can use-500 bar, (15) testing pressure 700 bar. [ warranty period: 24 months after the date of delivery ] ]
Tender For supply of voltas 320 ltrs deep freezer repair,1 and half ton window ac repair lg,100 ltr water ro repair and servicing,1 and half ton videocon ac repair,purchase of cooler grass small,purchase of cooler grass medium,purchase of cooler grass large,replacement of cooler fan motor,replacement of cooler fan,replacement of cooler waterpump,replacement of cooler waterpump pipe,replacement of cooler switch plate,replacement of cooler waterpump large,replacement of cooler capacitor,cooler wiring repair,bicycle repair,diesel generator set 15 kw three phase engine
Tender For operation watch and ward of departmental portable diesel engine driven dewatering pump sets of various capacities deployed at various locations in district jammu.
Tender For corrigendum : engagement of agency for overhauling of mechanical items of alco locomotives - diesel engine (power pack) complete (without alternator, tsc, waterpump & lube oil pump), abb/ge turbosupercharger, air compressor-3cdb with both end couplings, waterpump assembly with gear, lube oil pump assembly with gear, rttm blower, radiator fan with housing, radiator assembly, universal shaft/coupling, fuel oil relief valve, fuel oil regulating valve, lube oil relief valve, lube oil regulating valve, lube oil filter drum assembly, pre lube oil pump, online centrifuge, fttm blower, air dryer, irab1 brake system with all valves including feed valve (loco set), horizontal shaft, inertial air filtration system (air compressor room & main alternator room), fuel booster pump, fuel oil primary filter housing, fuel oil secondary filter housing, plate type lube oil cooler, large aftercooler core assembly, pipelines with fittings of water system (loco set), pipelines with fittings of lube oil system (loco set), pipelines with fittings of air system (loco set), condition base items as per boq2
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw waterpump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For redrilling of existing borewells and installation of motor starter near durugamma temple and narendra house and eshappa house in ward no 12 and purchasing of diesel engine waterpump to ir for drinking water purpose turvihal town
Tender For design, supply & installation of independent trolley fire tender of capacity 5000 litre equipped with diesel engine driven high pressure pump, afff induction system & hose reels as per details attached in annexure a. [ warranty period: 30 months after the date of delivery ] ]