Get complete information related to latest Ceramic Fiber Tape Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ceramic Fiber Tape Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ceramic Fiber Tape Tenders.
Tender For corrigendum : supply of 4500 sets of stay set complete - supply of silicagel blue, 0.6kva ups, stay set complete( quote price for single unit only), silicagel blue 10 to 12mm, pole pit for 9.0m and 9.14 m psc/rcc / all metal poles (each pit) 1.25 x 0.6 x 1.83 mtr, ordinary soil, semi rocky soil, heavy rocky soil where blasting/ cheseling required [specific approval should be obtained from concerned ee], stay pit, in ordinary soil [0.95 x 0.6 x 1.2m], semi rocky soil, stay pit in heavy rocky soil where blasting/ cheseling reqiured [specific approval should be obtained from concerned ee], erection of poles & stays (including refilling of excavated earth), erection of 7.5m / 8.0m poles [rcc / psc], erection of 9.00m / 9.14m rcc / psc/rail pole, tubular pole and all metal poles, stay set, erection stay set complete, stay erection without rod and pit, replacement of stay rod only. (including stay pit excavation & refilling & erection), replacement of guy shackle only in existing stay, erection of line materials, fixing of lt 1 ph "x" arm, fixing of lt/ht ti fitting, fixing of lt 3 ph "x" arm, fixing of 3[1/2] v ` x arm, fixing of 4[1/2] v ` x arm, fixing of 5 v x arm, fixing of tapping channel / guarding "x" arm, providing of line spacers in lt lines 1 phase, providing of line spacers in lt lines 3 phase, erection of ab switch with pt insulator & jumpering complete, erection of centre rotating switch ab switch complete, fixing of ht pin insulator / strain disc, 11 kv pin insulator with pin, 11 kv strain disc / polymer disc with hardware, 22 kv pin insulator with pin, 22 kv strain disc / polymer disc with hardware, 33 kv pin insulator with pin, 33 kv pin strain disc/polymer disc with hardware, fixing of lt pin insulator with pin, lt shakle with hardware, fixing of aluminium knob, paving stringing and sagging of conductor including binding of pin and proper tight [including transport of condutor from road side to work spot] per run, upto 7/2.59 mm acsr, 7/2.50 aaac including pvc cable upto 25 sqmm, acsr 7/3.35mm & 7/ 3.15 aaac including pvc cable above 25 sqmm, acsr 7/4.09 mm, above 7/4.09 mm acsr & dog conductor, earthing wiring and connection including transporting of earth pipe and excavation of pit], transformer structure earthing 10ft depth - 3 nos of pipe through tubes, dp earthing including all works [double side earthing], erection of 4th earth pipe including earthing, earthing of poles, earth pit masonary work 3 nos earth pits or using 3 nos concrete tub., replacement of detoriated earth pipe per location, concreting with mixture 1:3:6 [including all materials]., mass concreting for centre support for 2 feet including all materials, mass concreting for pole0.6x0.6x1.25m.with coping, sleeve concreting for pole 0.6 m x 0.6m x 0.3 m with coping, sleeve concreting for stay set 0.3 m & 0.75 long, erection of distribution transformer structure complete, excavation of structure pole pits 0.9 x 0.9 x 1.83 mtr, transporting of pole to pit location 2 nos., erection of poles 2 nos, excavation of stay pit 4 nos, erection of stay set (4 sets), mass concreting (cement:sand:jelly supplied by the contractor) 2 nos., erection of 22 kv ab switch, ttransformer structure earthing 10ft depth - 3 nos of pipe through earth tubes, erection of top channel, bed channel [2 nos channel] erection, cross with stud for bed channel erection, erection of belting angle / hg fuse angle, erection of hg fuse set, erection of ht las with jumpering and earthing, erection of lt las with jumbering and earthing, erection of jumpering [ht side], transformer wiring in lt side including jumpering bus bar etc., erection lt open type fuse unit arrangement single, erection lt open type fuse unit arrangement double, painting of stru. complete excluding dt [two coat of red oxide] all metal parts(excluding cost of paint)., painting of stru. complete excluding dt [one coat alu paint, excluding cost of paint), colour washing of 2 numbers structure p
Tender For corrigendum : tender for supply of sleeve of esp id 24.5x4 mm , shaft insulator , sleeve for d-50 shaft , sleeve for guide bar , vertical stay od 43 mm , length 4265mm , thickness 4.05 mm , moc is 1239 , set ring d 50 for esp (coll. elect. rapp. mech. pgma 77-125 for esp faa-6x37.5m-2x108150-2) , cerm shaft dia 50 mm 1 set consists of shaft end 1 no , shaft-3 nos , sleeve-2 nos , set ring-2 nos. , emitting rapping shaft , outer arm for colleting rapping system , inner arm assembly with fastener , support insulator (porcelain) , id 373 mm , length 372 mm , thickness 29 mm , coupling of shaft dia 50 mm- spare of esp , shock bar guide bar front side , shock bar assembly , coupling clutch for dia 50 shaft , guide clamp for esp , plain bearing , outer arm for emitting electrode
Tender For corrigendum : supply of spares of field switches for drills e e - shunt trip coil assembly, part no - v0021 , electrical release coil assly, part no - v0022 , aux. switch assy, part no - v0024 , soloinoid coil for closing mechanism, part no - v0025 , antipumping realy for solinoid, part no - v0026 , closing contactor for solenoid, part no - v0027 , flex connector, part no - v0028 , support insulator single hole for vcb, part no - v0031 , secondry plug and socket, part no - v0032 , fibre glass barrier set for fixed type v, part no - v0039 , drive insulator for vcb, part no - v0041 , vacuum interrupter, part no - v0048 , vacuum circuit braker assly. vcb9576, part no - vfs0062 , indicating lamp, part no - p0043 , trip neutal close switch, part no - p0045 , rectifire capacitor, part no - p0048 , earth leakage relay, part no - p0049 , over current relay single pol, part no - p0050 , resin cast core balance transformer, part no - p0051 , potential transformer 11 kv 110 v,100, part no - p0053 , resin class ct class isp10 ci10, part no - p0056 , 6.6 kv plug complete, part no - p0064 , 6.6 kv socket insulator, part no - p0065 , idmt relay, part no - p0083 , motor protection relay, part no - fsv00121 , ht hrc fuse for p.t., part no - fsv00110 ) /bid number : gem/2026/b/7522304 * /dated: 09-05-2026 & & / bid document 1 / 32
Tender For supply of esp heaters, insulators and associated spares for coh of unit #3 at em_i,210 mw cstps chandrapur- heating elements for hopper 415 v 500 w, support insulator heater 415 v, 1 kw, shaft shaft insulator heater 415 v, 1 kw, bhel 500 mw suport insulator cstps u#5/6, spare insultr for field discnctg/es assy, esp 90kv seal off bushing, bhel 500 mw shaft insulator cstps u#5/6
Tender For supply of materials and erection for shifting of control room pannel at 33/ 11 kv sub station bharsawa distt. kaushambi under deposit scheme on turnkey basis under edc, kaushambi - name of work: supply, carriage & erection of materials for control room pannel shifting of shiffting of 33/11 kv s/s bharsawa distt. kaushambi, supply of centralised materials, 11 kv switch gear 600/300/5a 350 mva i/c, 11 kv switch gear 200/100/5a 350 mva o/g, 11 kv 3x300 mm2 xlpecable, 11 kv 3x120 mm2 xlpecable, 24 volt battery, 24 volt battery charger, pcc. 8.5 mtr. long for feeder, 11 kv tpmo switch with fixing clamp, 11 kv top channel, 11 kv dropper angle, earthing complete, stay set complete, 11 kv polymer pin insulator, 11 kv polymer disc insulator, 11 kv disc fiting, 33 kv control panel t/f, acsr weasel conductor, supply of de-centralised materials, 11 kv 3x120 mm2 xlpe cable jointing kit o/d & i/d, control cable 4x2.5 mm2, control cable 2x2.5 mm2, g.i. pipe 6 " dia, rubber matting, clamp with nut & bosts, earth wire clamp for pcc pole, stay clamp for pcc pole, top channel clamp pcc pole, dropper channel clamp pcc pole, g.i. strip 35x6 mm, carriage of following material, pcc pole 8.5 mtr. long., structure of la, 33kv isolator, 33 kv cts, single t/f control pannel, 33kv vcb,11 kv outgoing. incoming pannel, battery & battery charger and other associated accessiories etc. (availibility at concern store center of store division), erection work, installation of 33 kv single transformer control pannel 2 no., incoming 2 no. and 7 no. outgoing in the switchgear room and grouting the pannel by rag bolt using cement, sand mortar in ratio 1:3. work includs fitting of all accessories in all respect with complete connection of control cable with pannel. all material will be provided by the contractor except vcb and crp., construction of cable trenchs with top cover and laying of control cable for vcb, c.t. & t/f control pannel etc. as per direction of engineer. trenchs to be 12 wide and 9 deep. work includes digging, of trench, concreting of the foundation in the ratio 1:3:6 r.b. wall 9 wide with cement mortar 1:4 and plastering inside the trench in the ratio 1:3 and sand filling in the trench. all material will be provided by the contractor., earthing of 11 kv indoor equipments, switchgears as per resspo drawing. with g.i. strip of size 35x6 mm. g.i. strip fully welded at both ends and to be connected with earthmat,, erection of dp with pcc pole 8.5 mtr long with all accessaries and grouting of the pcc pole with cement, sand and brick ballast ratio 1:4:8 size 0.45x 0.45x 1.5 mtr deep under the ground as per drawing no. res-6.(cement, sand, brick, ballast shall be provided by the contractor.), installation of 24 volt battery and battery charger with cabinet in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. fixing of rag bolt., laying of 11 kv 3x300/3x185/ 3x120 sqmm. xlpe cable by digging 0.75 mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it rmt and covering the cable from sides and top by laying bricks, finally covering the same by earth and levelling of the same, all the materials, except cable, will be pvovided by the contractor., fixing and termination of outdoor/ indoor heat shrinkable cable boxes of size 3 x300/3x185/3x120 sqmm. xlpe cable. boxes will be supplied by the contractor, sundries ( as per site requirement/emergency work), safe dismantling of 11 kv o/g pannel & received back to store, laying of weasel conductor with the help of aluminium roller by hanging three nos. on each support in a manner taking sufficient care to ensure safety of weasel conductor against rubbing on ground, precaution for safety of crops is also to be taken. the work includes jointing of conductor by providing jointing sleaves, stringing of conductor upto correct sag and binding of conductor with insulators on each support. all material shall be provided by contractor such as join
Tender For supply of hammer assembly ce rapping system , rigid bearing assembly ce rapping system , live bearing assembly of ce rapping system , rapper block shock pad of ce hanging system , support insulator of discharge electrode rapping system , hammer assembly discharge electrode raping , rigid bearing assembly of discharge electrode raping , live bearing assembly de rapping , shaft insulator of discharge electrode raping system , shaft coupling , driver shaft ce rapping , driving shaft de rapping 4