Get complete information related to latest Ceramic Plug Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ceramic Plug Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ceramic Plug Tenders.
Tender For supply of solar fencing materials to tool room at mannamangalam forest station in pattikkad range during 2026-27 - energiser with 10kv output saftey standards with bis 302-2-76 iec 335-2-76, switch high-medium-low power setting. solar panel option to recharge 12v battery, full and reduced power output terminals operate different fences independently, supply of corner post assembly -. 8 ft, gi 2, 14 guage thickness, 50nv class b pipe -hot dip galvanized to more than 60 microns-must include fasteners- including cost of gi pipe, painting, supply of supporting posts 8 ft gi-1, 14 guage thickness 50 nv class b pipe -hot dip galvanized to more than 60 microns-must include fasteners- including cost of gi pipe, painting, intermediate posts;8 ft (25mmx25mmx3mm) insulated t post or 16mm tmt rod hot dip galvanized more than 60 microns, including cost of t post, strain insulator -must of polypropelene plastic rated for 15 kv, uv stabilized, pp reel insulator - must be of virgin plastic material polypropelene or equivalent., wire tightener -in suit tightners for proper tensioning of wires should be made from al alloy-non rusting quality mechanical strength 500n., battery water, supply of 12 guage acsr wire;12 guage 2.5mm wire dia high tensile wire with minimum of 230-300gms/sq.m zinc coated thickness. uts 140.5 kg/mm2, break strength of 740kgs, zn purity above 99%
Tender For supply of solar fencing materials to tool room at pattikkad forest station in pattikkad range during 2026-27 - energiser with 10kv output saftey standards with bis 302-2-76 iec 335-2-76, switch high-medium-low power setting. solar panel option to recharge 12v battery, full and reduced power output terminals operate different fences independently, supply of corner post assembly -. 8 ft, gi 2, 14 guage thickness, 50nv class b pipe -hot dip galvanized to more than 60 microns-must include fasteners- including cost of gi pipe, painting, supply of supporting posts 8 ft gi-1, 14 guage thickness 50 nv class b pipe -hot dip galvanized to more than 60 microns-must include fasteners- including cost of gi pipe, painting, intermediate posts;8 ft (25mmx25mmx3mm) insulated t post or 16mm tmt rod hot dip galvanized more than 60 microns, including cost of t post, strain insulator -must of polypropelene plastic rated for 15 kv, uv stabilized, pp reel insulator - must be of virgin plastic material polypropelene or equivalent., wire tightener -in suit tightners for proper tensioning of wires should be made from al alloy-non rusting quality mechanical strength 500n., battery water, supply of 12 guage acsr wire;12 guage 2.5mm wire dia high tensile wire with minimum of 230-300gms/sq.m zinc coated thickness. uts 140.5 kg/mm2, break strength of 740kgs, zn purity above 99%
Tender For corrigendum : supply of connector, 'd' type plug 9 male solder contacts g. f polyester insulator j50820/02- 036 style. , mtg. accessories for 9pin d type connector, back hood plastic with strain relief clamp hard ware , dd6c4000048a1a4-mtg. accessories, housing for 2.5 mm 5 contacts, st. connector , dd6c4000001c1a4- female housing, 2mm pitch, 5 pin , dc4c2100012a1a2- connector, crimp female contact , dc4c2050022a7a2-crimp terminal female contact for 2 mm pitch, pin friction lock headerph -connector , connector, 'd' type socket, 9 female solder contacts pbt insulator j 5082001-036 style. , dc4e2201552nsa2- connector, high density 15 pin d-sub male, solder bucket , dc4c2100024a1a2-connector housing receptacle dual 10 positions , terminal short point crimp snap-in receptacle contacts, loose form , mtg. access, hood for 9pin d type connector, top cable entry with cable clamp & jack screws.
Tender For corrigendum : supply of 4500 sets of stay set complete - supply of silicagel blue, 0.6kva ups, stay set complete( quote price for single unit only), silicagel blue 10 to 12mm, pole pit for 9.0m and 9.14 m psc/rcc / all metal poles (each pit) 1.25 x 0.6 x 1.83 mtr, ordinary soil, semi rocky soil, heavy rocky soil where blasting/ cheseling required [specific approval should be obtained from concerned ee], stay pit, in ordinary soil [0.95 x 0.6 x 1.2m], semi rocky soil, stay pit in heavy rocky soil where blasting/ cheseling reqiured [specific approval should be obtained from concerned ee], erection of poles & stays (including refilling of excavated earth), erection of 7.5m / 8.0m poles [rcc / psc], erection of 9.00m / 9.14m rcc / psc/rail pole, tubular pole and all metal poles, stay set, erection stay set complete, stay erection without rod and pit, replacement of stay rod only. (including stay pit excavation & refilling & erection), replacement of guy shackle only in existing stay, erection of line materials, fixing of lt 1 ph "x" arm, fixing of lt/ht ti fitting, fixing of lt 3 ph "x" arm, fixing of 3[1/2] v ` x arm, fixing of 4[1/2] v ` x arm, fixing of 5 v x arm, fixing of tapping channel / guarding "x" arm, providing of line spacers in lt lines 1 phase, providing of line spacers in lt lines 3 phase, erection of ab switch with pt insulator & jumpering complete, erection of centre rotating switch ab switch complete, fixing of ht pin insulator / strain disc, 11 kv pin insulator with pin, 11 kv strain disc / polymer disc with hardware, 22 kv pin insulator with pin, 22 kv strain disc / polymer disc with hardware, 33 kv pin insulator with pin, 33 kv pin strain disc/polymer disc with hardware, fixing of lt pin insulator with pin, lt shakle with hardware, fixing of aluminium knob, paving stringing and sagging of conductor including binding of pin and proper tight [including transport of condutor from road side to work spot] per run, upto 7/2.59 mm acsr, 7/2.50 aaac including pvc cable upto 25 sqmm, acsr 7/3.35mm & 7/ 3.15 aaac including pvc cable above 25 sqmm, acsr 7/4.09 mm, above 7/4.09 mm acsr & dog conductor, earthing wiring and connection including transporting of earth pipe and excavation of pit], transformer structure earthing 10ft depth - 3 nos of pipe through tubes, dp earthing including all works [double side earthing], erection of 4th earth pipe including earthing, earthing of poles, earth pit masonary work 3 nos earth pits or using 3 nos concrete tub., replacement of detoriated earth pipe per location, concreting with mixture 1:3:6 [including all materials]., mass concreting for centre support for 2 feet including all materials, mass concreting for pole0.6x0.6x1.25m.with coping, sleeve concreting for pole 0.6 m x 0.6m x 0.3 m with coping, sleeve concreting for stay set 0.3 m & 0.75 long, erection of distribution transformer structure complete, excavation of structure pole pits 0.9 x 0.9 x 1.83 mtr, transporting of pole to pit location 2 nos., erection of poles 2 nos, excavation of stay pit 4 nos, erection of stay set (4 sets), mass concreting (cement:sand:jelly supplied by the contractor) 2 nos., erection of 22 kv ab switch, ttransformer structure earthing 10ft depth - 3 nos of pipe through earth tubes, erection of top channel, bed channel [2 nos channel] erection, cross with stud for bed channel erection, erection of belting angle / hg fuse angle, erection of hg fuse set, erection of ht las with jumpering and earthing, erection of lt las with jumbering and earthing, erection of jumpering [ht side], transformer wiring in lt side including jumpering bus bar etc., erection lt open type fuse unit arrangement single, erection lt open type fuse unit arrangement double, painting of stru. complete excluding dt [two coat of red oxide] all metal parts(excluding cost of paint)., painting of stru. complete excluding dt [one coat alu paint, excluding cost of paint), colour washing of 2 numbers structure p
Tender For material supply for the installation of 4 line hanging solar power fence at perambra estate - hanging solar power fence, p.p reel insulator-must be of virgin plstic material.polypropylene or equivalent with break down voltage of 15 kv(weight 25gm avh, length 4.6 cm avg), strain insulator- must of poly polypropylene plstic rated for 15 kv uv stabilized,(weight 40gm avg, length 7 cm avg), gi post 12 feet-2" gi pipe guage thickness, total 14.5 ft length modified to 12 feet length and cut and welding to 90 degree bend 2.5 feet length at top end and having diametrically opposite holes of size 6mm at end of bend pipe, intermediate post (t angle post)-6ft.,paited(25mmx25mmx3mm)having holes of size 6mm at required interval of fencing installation, supporting post- 10ft., gi-1",14 guage thickness,painted, stay (t angle)-2 ft., painted(25mmx25mmx3mm), 12 swg ht wire-12 guage,25mm dia high tensile with zinc coating for use as conducting wires for binding strain inulator, 14 swg binding wire- high quality zinc coating wire for binding reel insulators,tighing support post with corner post, 1.5 mm stainless steel wire rop 304 grade-1.5 mm stainless steel wire rop 304 grade, aluminium ferruel- aluminium ferrule inner dia 3mm, wire tightner- permanent wire tightner made of special aluminium alloy designed for kv,uv stabilized, earth rod- copper plated earth rod 14mm -3 ft. length, earthing compound- earthing compound 8kg, gate handle- gate handle and spring assembly. handle made of polyethyelene, leadout cable- lead out cable for fencie system double insulated gi cable inner core wire 2 sq.mm. hot dipped galvanlsed steel core, cable of with standing 15 kv should be provided to prevent bimetal salt formation at connections, single core 2.5 mm sq. cable- 2.5 mm2 single core copper cable for connecting the solar panel to the tuber battery through charge control unit with required terminal sockets, nut and bolt, washer, lightining diverter- 15 kv rod gap arrester,must be capable of diverting stray lightining and adjustable for spark raps adequate earthing to be provided, 100 watt solar panel- 100 watt/12 volt and above poly crystalline with 10 year warranty having iec/mnre certification, charge control unit- 20a, 12/24 v pwm charge controller unit of standard make suitable to control the charging of the tubular battery, energizer- energizer with 10 kv output safety standerds to be followed and bis 302-2-76 iec60335-2-76. switch high,medium and low power of settings, fence alarm system- fence alarm system conering area of 1.5 km, solar panel supporting stand with metal box painted ( for battery and energiser)- 18 guage thickness metal box (lockabe). gi sheet, painted should be capable of housing battery, charge controller and energizer and fixed with required clamps and nud and bolt on solar panel support stand made of gl pipe of 50mm daimeter and b class type with suitable arrangement for holding the panel, warning sign- polyethylene plastic with satuatory warning with signs, tubular battery 12v,100ah- 12v, 100 ah c10 rating with full 5 year replacement warranty(tower battery) for energising the energiser
Tender For corrigendum : supply of deflector side liner leading mill hp1103 , deflector liner lower,sl-15 mill hp1103 , deflector liner lower,sl-20 mill hp1103 , deflector liner mid,sl-25 mill hp1103 , deflector liner mid,sl-30 mill hp1103 , intermediate liner leading mill hp1103 , intermediate liner trailing mill hp1103 , ceramicplug for deflector liner hp1103 , welding plug for deflector liner hp1103 , air restriction ring segment , deflector liner mid,sl-35 mill hp1103 , seal wear ring for journal mill hp1103 , head liner- 4 for head liner assembly , head liner-2 for head liner assembly , head liner-6 for head liner assembly , trunion shaft bushing for coal mill hp1103
Tender For supply of replacement damped vacuum tank door spring part no 32752 , upgrade kit for damped vacuum tank front door spring assembly part no 32753 , upgrade kit for damped vacuum tank back door spring assembly part no 32754 , load unit water distibutor manifold part no 31622 , load unit air and water manifold part no 31604 , active pirani rough vacuum gauge part no gauge101 , active magnetron high vacuum gauge part no gauge102 , active pirani gauge replacement tube part no gauge101a , supernut assembly part no hn100 , 3 by 4 inch 10 x 8 inch hhb grade 9 bolt part no 33929 , 3by 4 inch flat l9 washer part no hn030 , jack screw for mcu supernut assembly part no hn101a , superbolt lubricant part no hn101b , flat hot grips inch stainless 5mm spring pin 3 point 0mm to 4 point 25mm set of 4 pcs part no 9016 030 , round grips inch full contact stainless steel 10mm set of 4 pcs part no 9065 100 , round grips inch full contact stainless steel 6 mm set of 4 pcs part no 9065 060 , round grips inch partial contact stainless 6mm set of 4 pcs part no 9060 060 , round grips inch partial contact stainless 10mm set of 4 pcs part no 9060 100 , round grips inch full contact cu alloy 6 mm set of 4 pcs part no 9000 060 , graphite foil punch 3 by 4 inch diameter part no tool012 , punch pad for foil punch part no tool011 , automatic specimen loading tool part no 32782 , specimen loading clip for plane strain specimens 10mm x 15mm x 20mm part no 33780 , specimen loading clip for flow stress specimens 10mm diameter x 9mm length minimum part no 33782 , specimen loading clip for flow stress specimens 8mm diameter x 10mm length minimum part no 33795 , specimen loading clip for flow stress specimens 6mm diameter x 9mm length minimum part no 33796 , iso t uniaxial compression anvil cap high temperature part no 9220 069 , low force wedge jaw assembly part no 9510 101 , replacement transducer assembly for 39050 and 39052 jaw to jaw l strain assembly 1 by 2 inch travel part no ga000192 , hydrawedge ii l strain system part no 39057 , cct dilatometer assembly with lvdt transducer part no 9655 001 , universal extensometer mount part no 9655 100 , fine wire thermocouple welder rebuild kit part no 35202 , cct dilatometer tygon tubing 1 by 16 in id x 3 by 16 in od part no tu314 , thermocouple single hole ceramic insulating tubes set of 5 part no tc007 , double hole round ceramic thermocouple insulator part no tc026 , clear teflon tc insulator tubing part no tu010 , black teflon tc insulator tubing part no tu011 , thermocouple red push post part no g176b , thermocouple black push post part no g176c , replacement 110 silicon o ring part no ors110 , normally open dump valve c10 2 cavity part no vlv104 , normally close dump valve c10 2 cavity part no vlv105 , load cell calibrator spherical washer set 0 point 75 inid x 1 point 630 inod x 0 point 38 in thk blk part no wa0750 01