Web Analytics Made Easy - StatCounter

Certification Work Tenders

Get complete information related to latest Certification Work Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Certification Work Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Certification Work Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :40126145 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

corporations/Associations/Others

CTN :40126147 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

Central Government/Public Sector

CTN :40134626 Due date: 16 May, 202516 May, 2025 23.54 Lacs
Tender For providing of custom bid for services - appointment of agency for undertaking iso 9001:2015 re-certification/certification work of various terminals/offices of concor (pan india basis)

Central Government/Public Sector

CTN :40106431 Due date: 05 May, 202505 May, 2025 NA
Tender For supply of 2 leg (multi) twin path slings with check fast system and overload indicators, cover max cove r on slings capacity- 16t, length- 3 mtrs. as per american standard- ansi/asme b30-9 and international st andard iso-4878 along with following facilities (a) slingset polyester round slings 25 ton capacity master o- ring with 1 meter circumference. (b) slingset twin path slings with check fast system, overload indicators- 1 0 ton capacity each sling length 3 meter effective. (c) each slings is fitted with 10 ton capacity d shackles. (d) end of d shackles is fitted with 10 ton capacity of eye hooks. technical details as per annexure attache d. note: firm should submit test certificate. test certificate must be produced duly tested from governme nt approved labs along with the material or else material shall be rejected. [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :40106731 Due date: 09 May, 202509 May, 2025 NA
Tender For flash back arrestor for acetlyene gas regulator conform to bis:6158-198 2 or iso: 5175-1987 or latest version. max. inlet pressure-10 bar (150 psi). make/brand-m esser or ador or l&t or esab part no. 0430-0100-402 or gce part no.0764471. only oem o r their authorised dealer can participate in the tender. work test certificate is requi red . sample to be got approved from consignee before bulk supply. [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :40107378 Due date: 05 May, 202505 May, 2025 NA
Tender For supply of flash back arrestor(dry type) for regulator end of oxygen lines to preven t flash backs in oxy fuel system conforming to en 730/iso 5175-1/is 11006 standards with flame arrestor(fa) and non return valve(nrv) and thermal cut off valve(tv) working p ressure:15 bar. end connections g 3/8" rh to en 560/iso 3253 standards. make: messer(dg n oxy) or esab(protex ro) or gce(fr-34 r oxy) or weldstar(fire pro ro) only. note:1) off ers of oems or their authorised dealers enclosing valid authorised dealership certific ate only will be considered. 2) the suppliers shall send test certificate from govt. aut horised test house. in case of international brand, the test certificate from reputed in stitute like bam, germany is mandatory. 3) the suppliers should have equipments for tes ting of flash back arrestors and calibration. the purchaser has the right to inspect t hese installations. specn: en 730/iso 5175-1/is 11006 [ warranty period: 12 months after the d ate of delivery ]

Central Government/Public Sector

CTN :40094521 Due date: 02 May, 202502 May, 2025 NA
Tender For supply of flash back arrestor(dry type) for torch end of acetylene/lpg lines to prevent flash backs in oxy fuel system conforming t o en 730/iso 5175-1/is 11006 standards with flame arrestor(fa) and non return valve(nrv) working pressure: 1.5 bar for acetylene/5.0 b ar for lpg. end connections g 3/8" lh to en 560/iso 3253 standards. make: messer(cg-91 fuel) or esab(fr-18) or gce(fr-20t fuel) only. not e:1) offers of oems or their authorised dealers enclosing valid authorised dealership certificate only will be considered. 2) the suppl iers shall send test certificate from govt. authorised test house. in case of international brand, the test certificate from reputed ins titute like bam, germany is mandatory. 3) the suppliers should have equipments for testing of flash back arrestors and calibration. th e purchaser has the right to inspect these installations. spec:en 730/iso 5175-1/is 11006 [ warranty period: 30 months after the date of deliver y ]

CTN :40082335 Due date: 28 Apr, 202528 Apr, 2025 10.81 Lacs
Tender For requirement of instruments and consumable chemicals (uv vis spectrophotometer) - fixed volume pipettes 1 ml. now, silent and effortless with textured adjustment knob for a firmer feel (thermofisher/eppordorf/brnds) alongwith 200 tips autoclavable., fixed volume pipettes 10 ml now, silent and effortless with textured adjustment knob for a firmer feel (thermofisher/eppordorf/brnds) alongwith 10 tips autoclavable, fluoride standard- 1000 ppm nist traceable with certificate make merck sigma- 500ml atleast with 2-3 years expiry date with iso: 17034, iron standard - 1000 ppm nist traceable with certificate make merck sigma- 500ml atleast with 2-3 years expiry date with iso: 17034, nitrate standard- 1000 ppm nist traceable with certificate make merck sigma- 500ml atleast with 2-3 years expiry date with iso: 17034, photometric test kit for measurement of iron fe number of tests: 100 (powder pillows) sample volume required: 10ml compatible with photometers: 0.00 - 3.00 mg/l fe atleast with 2-3 years expiry date, photometric test kit for measurement of nitrate no2 number of tests: 100 (powder pillows) sample volume required: 10ml compatible with photometers: photoflex 0.00 - 0.33 mg/l no2-n: 0.00 - 1.08 mg/l no2 atleast with 2-3 years expiry date, photometric test kit for measurement of sulfate so4 number of tests: 100 (powder pillows) sample volume required: 10ml compatible with photometers: photoflex 0 - 70 mg/l so4 atleast with 2-3 years expiry date, round 16 mm quartz cells round cuvettes, empty (16 mm diameter). (as compatiable with instrument), sulfate standard- 1000 ppm nist traceable with certificate make merck sigma- 500ml atleast with 2-3 years expiry date with iso: 17034, cmc for spectrophtometer for 2 years after completion of 3 years warranty, credit of old dr 6000 spectrophotometer (unrepaired) complete in all respect. , "us vis spectrophotometer with double beam source lamp: tungsten(visible range), typical wavelength range: 190-1100 nm, wavelength accuracy: 1 nm but not less than0.5 nm, spectral bandwidth: 2 nm but it should not be more than 4 nm, scanning speed: max 2000 nm/min (in 1 nm steps), etc. and instrument complete in all respect as per standard specifications exclusive of gst.(make: hach/ wtw-xylem/ thermo orion/ lovibond), warranty: 3 years.", 10mm 1 rectangular cuvette quartz, layer thickness 10 mm. quartz cells (as compatiable with instrument), 20mm- 1 rectangular cuvette quartz, layer thickness 20 mm. (as compatiable with instrument), 50 mm quartz cells -1 rectangular cuvette quartz, layer thickness 50 mm. (as compatible with instrument)

State Government

CTN :40044754 Due date: 23 Apr, 202523 Apr, 2025 NA
Tender For request proposal for supplying various equipment, chemicals, standard reference microbial cultures, glasswares/ plasticwares and general items in 13 numbers of district level water testing laboratories of jharkhand a-ranchi zone - refrigerator- ( 265 litre approx., double door ),make & model: branded ( is standard), analytical balance-( 4digit), weighing capacity of 220g, externally calibrated by nabl accredited lab/agency with calibration certificate, make & model: branded) ( is standard), ph meter-(measuring range ph0.0-14.0), make & model: branded ( is standard), hot plate with magnetic stirrer-(power: 2000 watt approx., operating volts: 230 15 volts a/c), stirring capacity : 50-1500 rpm, plate size : 1 ft *1.5ft (approx), make & model: branded ( is standard), bacteriological incubator-digital construction -double walled construction outer body made of mild steel powder coated & inner body made of stainless steel, insulation : glass woll insulation between two walls. inner size : 18" x 18" x 24", rating watts 750, no. of shelves 3, capacity 120 ltrs, temp range- 5 c - 60 c accuracy +/- 0.5 c, temp controlled by : controlled by pid micro process controller with dual display. selves : with g.i. wire mesh selves, door : 2 door inner acrylic door to view sample & outer metal door with air circulation motor with blower for uniform temperature throughout chamber. heater : special nichrome heater designed for long life & saving of power consuption. thermometer type : electronic with digital display. make & model : branded ( is standard), laminar air flow chamber(biosafety cabinet)-external dimensions (lxwxh) in inches and mm:40 x34.25 x56.7, (1020 x870x 1440) work area dimensions: 34.45 x24 x22.52 (857x610x572) material of construction: galvanised iron sheet with epoxy polyester thermosetting powder coating of 80 microns, 1.5mm thickness/stainless steel grade 304,1.2mm for ss modelsbody finish: glossy off white colour for gi powder coated table top: 1.2mm ss 304 sheet of matt finish pressed on 25mm solid nuwud board side glass: 6mm float glass encased in stainless steel channels front door: frameless gas spring loaded swinging type polycarbonate 6mm thickness wheels and levelling lugs: pu solid wheels with plated brackets and metallic powder coated design: front bottom loading pre-filters or completer work area with stainless steel including hepa grill cleanliness class: iso standard 14644-1- class 5 stages of filtration: a.pre-filters= 10 with an efficiency of 90 % washable hdpe media in frp pu coated frame b.mini pleat hepa filter encased aluminium frame with an efficiency of 99.995% motor blower assembly: variable speed mtor mounted on pu coated frp blowers with aluminium powder coated impellers velocity: 100 fpm at 6 from face of the filter noise level: less than 60db at 1 meter from the face of the equipmenthepa filter grill: stainless steel grills duly perforated and polished electrical specifications: a. switches and speed controller: microprocessor controlled feather touch switch panel b. fluorescent lighting: 18 watt. c. chokes for lighting: 18 watt d. ultraviolet lighting: 1.5 feet length g15t8, 15 watt power consumption: 250 watts lighting: greater than 800 lux power supply: 230v,50hz power supply, single phase 5 amperes power cord accessories: gas burner, gas/vacuum cock ( is standard), autoclave -vertical autoclave size 14" dia x 22" ht, rating in watts 3000, capacity of 52 ltrs complete s.s with foot lifting arrangement used for sterilization under saturated steam pressure at 15psi with double walled units with inner chamber made of thick stainless steel and outer chamber made of s.s.lid is made of thick gauge stainless steel with pressure gauge steam release valve, and safety valves. with foot lifting arrangement. with s.s. basketaccessories:1. digital temperature indicator cum controller with timer -1 no.2. water level cut off-1no.3. pressure cut off switch-1no. ( is standard), digit

Central Government/Public Sector

CTN :40058356 Due date: 25 Apr, 202525 Apr, 2025 NA
Tender For supply of def 20 litres capacity can aus 32 as per iso 22241-1 suitable for cpcb-iv norms diesel engi ne in lhb power car of mumbai division make. hpcl, bpcl,iocl,cummins kirloskar. the firm shall submit o em certificate or authorized dealership certificate. [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up