Web Analytics Made Easy - StatCounter

Change Over Switch Scrap Tenders

Get complete information related to latest Change Over Switch Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Change Over Switch Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Change Over Switch Scrap Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45713835 Due date: 18 Jul, 202618 Jul, 2026 30.00 Lacs
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc

State Government

CTN :45704949 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For supply, erection, testing and commissioning of ct meter of standard make with cubical meter box as per hvpnl specifications including 3 phase electrical meter 100/5 of standard make approved by hvpnl including ct/pt of suitable rating complete in all respect as per directions of engineer-in-charge ,mccb ,distribution boards, mcb`s, rccb`s, change over etc. 8.1. supply, installation, testing and commissioning four pole on load manual change over switch in ss enclosure of following ratings 63 amp 415 volts

corporations/Associations/Others

CTN :45667085 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For fire work at esic haryana. - (a) supplying, installation, testing and commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required :(b) horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520.(c) suitable hp squirrel cage induction motor, tefc, synchronous speed 1500 rpm, suitable for operation on 415 volts, 3 phase 50 hz, ac supply with ip 55 protection for enclosure, horizontal foot mounted typewith class-f insulation, conforming to is-325.(d) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) suitable cement concrete foundation duly plasteredwith anti vibration pads., 2280 lpm at 70 m head, (a) supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required:(diesel driven pump)(b) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520.(c) suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulatedwith 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event offault with audio indications, painted with post office red colour etc. as required.(d) m.s fabricated, common base plate, coupling, couplingguard, foundation bolts etc. as required.(e)suitable cement concrete foundation duly plasteredand with anti vibration pads., 2280 lpm at 70 m head, (a) supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (jockey pump)(b)horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is : 1520.(c) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase 50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class-f insulation, conforming to is : 325.(d) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) suitable cement concrete foundation duly plastered and with anti vibration pads., 180 lpm @70m head, fabrication, supply, insallation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :, incomings630a, 50ka 4 pole mccb, ics=100% icu rating digital voltmeter 0-500v with selector switch ammeter (0-630 a) with selector swtich & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps set of copper bus bar 800amps outgoings (note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump200 amp, 50ka tpn mccb, ics=100% icu, with f

Central Government/Public Sector

CTN :45329483 Due date: 29 Jun, 202629 Jun, 2026 12.61 Lacs
Tender For corrigendum : provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate nu

Central Government/Public Sector

CTN :45616892 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply, fixing, testing and commissioning of 200 kvar apfc panel, with cubical modular construction floor mounting dust and vermin proof made of 14/16 swg crca sheet as per latest approved specification is standard and harmonic block reactor with capacitors 25 kvar, 04 banks, capacitors 20 kvar , 02 banks, capacitors 15 kvar , 02 banks, capacitors 10 kvar , 02 banks capacitor 5 kvar , 01 banks, capacitors , 03 kvar , 01 banks, capacitor 02 kvar , 01 banks, comprising of housing, capacitors banks apfc relays, mccb/mcb protection, with all accessories including mounting arrangements suitable to work on 3 phase 440 volts,50 hz ac supply. features: automatically switch on and switch off relevant capacitor steps to ensure consistent power factor, continuously sense and monitor the load conditions by the use of the external ct ( whose out put is fed to the control relay), double side earthing connection, advance c-mos technology based microprocessor relay for intelligent power factor control, provision of top & bottom cable entry ,ensure easy user interface for enabling reliable understanding of system operation, such as display of real time power factor, number of switching operations carried out, test report from govt. lab/nabl /ilac lab to be submitted at the time of supply, specification as per iec 61921/ is 8623/ is 16636/ iec 61439.makeabb/ havells/ l&t/siemens or similar. [ warranty period: 12 months after the date of delivery ] ]

CTN :45444935 Due date: 18 Jun, 202618 Jun, 2026 NA
Tender For annual maintenance rate contract for repairs/replacement to 3-phase, a.c induction horizontal an vertical motors of pumping units. repairs /replacement to cubical control panel, panel board , switch gears etc. repairs/replacement to servo voltage st - annual maintenance rate contract for : repairs/replacement to 3-phase, a.c induction horizontal & vertical motors of pumping units. repairs /replacement to cubical control panel, panel board , switch gears etc. repairs/replacement to servo voltage stabilizers and manual operated voltage stabilizers. repairs/ replacement to ht/lt sub-station and its network. repairs /replacement to power conductor system, and electrification/illumination at various dewatering stations. details given in annexure b .

State Government

CTN :45375477 Due date: 06 Jun, 202606 Jun, 2026 5.29 Lacs
Tender For state plan- works under nedumkandam section-state plan 2024-25 - energy efficiency improvement, optimization of electromechanical items, safety audit and ensuring safety in operation of wtps and pump houses- rwss to udumbanchola - supply, e - cost of materials & working charges, od70149/2024-2025:1. pump & motor -supply, erection, testing and commissioning of kwa pre-qualified reputed make centrifugal pump set with bronze/ss impeller, ss shaft and ci pump casing etc. complete. the duty condition is as follows, discharge - 6 lps & total head - 92m, the motor is tefc squirrel cage induction motor suitable for the above pump working with 3 phase, 50 hz, 415 v shall confirm to eefi/is 325 etc. complete including providing suitable concrete foundation including cost of cement., sand and metal etc. flexible coupling shall be used for coupling of pumps and motors. 2. starter - supply, erection, testing and commissioning of suitable rating fullu automatic star delta starter with air break contact starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per ie rules and code of practice etc. complete. 3. panel board (suitable) for operating pump sets (but one pump set at a time) - supply, erection, testing and commissioning of cubical type floor mounted ms fabricated dust and vermin proof common control panel board consisting of 1 no. suitable capacity mccb as incomer and 2 nos of suitable capacity mccb as out going (the two mccbs are interlocking with each other) providing suitable size aluminium bus bar inter connect the above mccbs and fitted with 3 nos of indicator lamps, 1 no. volt meter with selector switch, 1 no. ammeter with selector switch etc. complete and provided with a common earth bus for the entire panel and inter connect with the mccbs as per ie rules and code of practice. the panel shall be fitted on a common base frame on suitable foundation. 4. cabling work - supply, laying, testing and commissioning of suitable size cables for the above pump set from panel board to starter and from starter to motor , considering energy conservation. 5 .earthing - supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing gi/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per ie standards. 6. capacitor - supply, erection, testing and commissioning of heavy duty app capacitor for the motor to get a power factor above 0.95. the capacitor shall confirm to is 2834 . 7. valves - supply of suitable size best quality heavy duty isi marked ci double flanged sluice valve and non return valve with suitable pressure rating 8. suction and delivery pipe connections - the size of the suction pipe is suitable as per the site condition with a max length of 7.5m. suitable size foot valve connecting at the suction pipe bottom etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.warranty 2 year (1 year warranty+ 1 year additional warranty), od109714/2024-2025:dismantling the existing old damged pump by disconnecting the cables, 15.2.1:demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in-charge.nominal concrete 1:3:6 or richer mix (i/c equivalent design mix), 4.3.1:centering and shuttering including strutting, propping etc. and removal of form work for:foundations, footings, bases for columns, 5.1.3:providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), 5.22.6:steel reinforcement for r.c.c work including straightening, cutting, bending, placing i

CTN :45239304 Due date: 25 May, 202625 May, 2026 28.10 Lacs
Tender For corrigendum : upgradation and replacement of old energy meter cubical panel board in switch room at pv hostel lodhi road new delhi.

CTN :45268466 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For annual maintenance rate contract for repairs /replacement to cubical control panel, panel board and switch gears etc. at various dewatering stations located in and around srinagar city

State Government

CTN :44720942 Due date: 29 Apr, 202629 Apr, 2026 NA
Tender For corrigendum : supply of netra sparc s7 , cpu 850 , point machine non trailable right , olm g12 , ecc cu card , lt pc skylake , 19 inch cubical kvm , tuning unit b1 , set of klv tempflex , switch ms655062x , clamp lock , snap switch new type , m module baseboard , point machine motor new type , busmaster unit buma card , disconnection switch and keys , neumann relay connecting module , switchover board a7 , switchover board a8 , switchover board a6 , olm p12 , chk key profile , vespe board , vesuv3 card , processing unit with memory venus2 card , tuning unit b17 , tuning unit b19 , tuning unit b24 , lan switch , neumann relay connecting cable , tuning unit b3 , tuning unit b16 , tuning unit b18 , tuning unit b4 , tuning unit b20 , tuning unit b23 , tuning unit b22 , m module baseboard ethernet , dc convertor psc 4402 , loop transreceiver module , kvm for mmi transmitter , dc convertor psc 4102 , simis tel. output module coated , psu 5v , switchover board , tcm100 to atp connecting cable , switchover board a5 , conductor plug , voltage cut off switch , hirchmann spider , switchover board a2 , switchover board a4 , switchover board a3 , drive rod right hand , drive rod left hand , touch display kvm , chk key , detection rod long 1690mm , detection rod long 560mm , tcm100 to ctr , connector for som6 ecc , overvoltage protector 24v , overvoltage protector 230v , transceiver m sfp , lock and key for point machine , crank handle , power supply filter , key operated switch with pulse function
 Loading, Please wait...

Connect us via What's Up