Get complete information related to latest Channel Cover Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Channel Cover Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Channel Cover Tenders.
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be
Tender For corrigendum : supply of 11e6 tube bundle , 11e2 tube bundle , 11e8 tube bundle , 11e45 a b tube bundle , e3222 tube bundle , 114e3078 a b tube bundle with fts cover , 114e3082 a b tube bundle with fts cover , 173e1192b tube bundle with fts cover , 11e23 a b e f channelcover monel clad , 23e01 channelcover monel clad , 102e3003b n shell
Tender For annual maintenance of gas crematorium equipment at mananthavadi municipality wayanad district proposed under 2025-26 annual plan. project no-1068 - civil work, od319315/2025-2026supply, replacement and servicing of automatic burner and fitting gas line., od319328/2025-2026cleaning of chimney surface, machinery repairing, removal of soot and rust, and applying primer with two coats of epoxy paint., od319385/2025-2026repairing damaged brickwork by removing broken bricks and replacing them with new bricks using cement mortar. the work also covers proper alignment,joint finishing, curing, and cleaning of the repaired area, complete as per direction of engineer-in-charge, od319413/2025-2026servicing and maintenance of the motor electrical system, such as inspection of wiring, terminals, switches and connections. it also covers tightening of loose connections, minor repairs, testiong for proper operation, and ensuring safe and smooth functioning of the motor., od319470/2025-2026reparing damaged or worn-out bed with 18 mm ss rod structures by alignment correction, replacement of defective parts if required, welding or fastening works, and ensuring proper strength and stability., od319499/2025-2026repairing of the gas valve system, such as cleaning , replacement of worn-out seals orcomponents if required, leak testing, and ensuring smooth and safe operation. the work shall be carried out as per safety norms., od319520/2025-2026removal of rust, scale, and old loose paint from equipment surface by wire brushing /scrapng, surface cleaning, application of suitable anti-corrosive primer, and finishing with two coats of approved paint. the work includes all materials, labour, tools and incidental charges required to complete., od319580/2025-2026comprehensive maintenance of the installed equipment for a period of one year, covering routine inspections,servicing, minor repairs,adjustments and ensuring continuous and safe operation. including survice of burner, blower, impeller and chimney. the rate includes labour, tools and incidental charges during the maintenanace period, excluding major replacements unless specified.
Tender For supply of -mechanical design and supply as per updated metallurgy of tube bundle, channel, channelcover, fts cover and backing ring - frta27 design and supply of exchanger components
Tender For tender for structural c c - visual inspection and photography performing a visual survey of the building and recording maping on drawing to assess extent of spelled concrete cracked concrete,honey combing,reinforcement corrosion , ultrasonic pulse velocity test for rcc structure in accordance with is 516 part 5 2018 section 1 by portable ultrasonic non destructive digital test equipment , rebound hammer test rebound hammer test in accordance with is 516 part 5 2018 section 4 by portable rebound hammer equipment at strategic locations , core test core cutting and compression test for rcc structure in accordance with is 516 on rcc members 70 mm core cutting in reinforcement concrete core filling by specialised epoxy , reinforcement mapping reinforcement mapping test on rcc structure to assess covers spacing bars including approximate diameter at strategic locations , chemical test for rcc structure in accordance with is 456- 2000 using ready made kits and reagents sample collected will be from half cell carbonatin powder i determination of ph value , half cell potential test for rcc structure in accordance with is 516 part 5 2018 section 2 half cell potential to assess the probality of corrosion of reinforcement at strategic locations , carbonation test for rcc structure in accordance with is 516 part 5 2018 section 3 carbonation test to measure extent of carbonation from the concrete surface at strategic locations , to check confirm present status of structure on basis on ndt results visual inspection , to provide recommendation for structure repairs and technical specification preparing bill of quantities for the repair etc all as specified and directed , vetting of report from iit nit * /bid number : gem/2026/b/7624255 + /dated: 24-06-2026 ' ' / bid document 1 / 14
Tender For construction and laying of inspection chambers and covers at various places in ward no. 13 in peddapalli town under municipal general funds (recall 1st)
Tender For supply of supply of hp heater 5 as per enclosed technical specification , supply of hp heater 6 as per enclosed technical specification , supply of lp heater 3 as per enclosed technical specification , vent orifice plate for hp heater 5 as per enclosed technical specification , vent orifice plate for hp heater 6 as per enclosed technical specification , vent orifice plate for lp heater 3 as per enclosed technical specification , gasket man hole door for hp heater 5 as per enclosed technical specification , gasket man hole door for hp heater 6 as per enclosed technical specification , gasket for tube sheet to shell flange joint for lp heater 3 as per enclosed technical specification , gasket for channelcover for lp heater 3 as per enclosed technical specification , tube plugs for hp heater 5 as per enclosed technical specification , tube plugs for hp heater 6 as per enclosed technical specification , tube plugs for lp heater 3 as per enclosed technical specification