Get complete information related to latest Chemical Bottle Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Chemical Bottle Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Chemical Bottle Tenders.
Tender For supply of lab items for eee and mechanical - eee and mechanical lab items, single phase transformer rating: 1 kva, 50 hz input: 230 v ac output: 115 v ac type: air-cooled, single-phase step-down transformer properly insulated input and output terminals brought out for safe operation, three phase transformer type: three phase transformer rating: 3 kva input voltage: 415 v ac, 3-phase output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory use bench/floormounted suitable for laboratory operation. all winding terminals shall be brought out to insulated terminals and enclosed within a protective outer cover for safe laboratory operation , on / off control of lamp using solid state relay kit type : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status , mcb elcb trainer kit 1 phase/3 phase, 2/3/4 pole, 3a-16a single pole mcb 2-5amps two pole elcb 30ma lamp load single phase 5amps panel enclosure and terminal outlets , single phase induction motor kit for load test by speed control of vfd (variable frequency drive) 2 hp single phase 230v complete load test experimental setup(with brake drum/pulley) induction motor -1 no work bench setup with digital meter -1 no motor stand with ant vibration bush 1 set loading arrangement with spring balance non-vibrating brake arrangement with stand and electrical work bench , 3 phase induction motor kit three phase squirrel cage induction motor with rope brake arrangement non-vibrating brake arrangement with stand and electrical work bench three phase squirrel cage induction motor 5 hp, 440 v, 1440 rpm, foot mounted type, frame size 132 mm, core length 110 mm, mechanical rope loading set up with 1" screw rods 2 nos, 6" adjustable wheels 6" 2 nos, back support frame, 9" aluminium drum, 0 50 kg spring balances 2 nos , dc shunt motor kit for load test dc shunt motor rope brake arrangement non-vibrating brake arrangement with stand and electrical work bench d.c. shunt motor 5hp, 220v, 1500 rpm, foot mounted type, frame size 132 mm, core length 110 mm, field current 0.5a, armature current 11a, 4 pole with inter poles, mechanical rope loading set up with 1" screw rods 2 nos, 6" adjusting wheels 6" 2 nos, back support frame 9" aluminum drum, 0 50 kg spring balances 2 nos. , bldc motor kit with electrical work bench *36v 400w bldc pro motor 1 no inbuilt volt and ammeter and rpm meter inbuilt power supply input 230v ac
Tender For corrigendum : supply of laboratory consumables - non vacuum test tube plain clot activator 0 point 5 ml , non vacuum test tube edta 0 point 5 ml , vacuum test tubes yellow 4 ml , vacuum test tubes red 4 ml , vacuum test tubes grey 2 ml , vacuum test tubes edta 2 point 0 ml , vacuum test tubes blue 2 point 0 ml , test tubes plastic 5 ml , test tubes glass 7 ml , test tubes glass 13 ml , test tubes glass 15 ml , micro centrifuge tube amber color 1 point 5 ml , conical centrifuge tube 15 ml , 2 way needle 22g , lancet 0 point 3 mm depth , round plaster 25 mm circular , alcohol swab width plus or minus 5 percent 35 mm length plus or minus 5 percent 50 mm 100 numbers per pack , tourniquet rubber length 10 inch , tissue roll 75 gsm , labels 48 x 24 mm , barcode label 25 x 50 mm , barcode ribbon thermal length 75 meter width 50 mm , blotting paper white 8 kg 150 gsm 46x58 cms 100 sheets per pack , filter paper whatman grade 4 , sterile container for urine sample collection 60 ml , acetone and glucose urine strip 100 strip per pack , albumin and glucose urine strip 100 strip per pack , 10 parameter urine strip 100 strip per pack , upt kit 50 test per pack , glucometer strips 100 strips per pack 500 strips for 1 glucometer free of cost , hemocuvettes dolphin 100 micro cuvettes , ehrlichs test 125ml , benedicts reagent 500 ml , liquor ammonia ammonium hydroxide 500 ml , sulphosalicylic acid 125 ml , barium chloride 10 percentage 500 ml , fouchets reagent 125 ml , sulfur powder 500 gm , stool occult blood card 50 test per pack , rotheras mixer for acetone 100 gm , acetic acid 500 ml , brilliant cresyl blue 25 grams , new methylene blue 5 grams , leishmans stain 500 ml , buffer ph 6 point 810 tablets per pack , dropper bottle 500 ml , pasteur pipette 3 ml , microscope slides frosted end 50 nos 25 x 75 x 1 point 35 mm , cover slip 22 x 22 mm 10 gram , cover slip 22 x 40 mm 10 gram , cedar wood oil 125 ml , ) /bid number : gem/2026/b/7446566 * /dated: 12-05-2026 & & / bid document 1 / 77 & & ' ' /item category lens cleaning solution for microscope 150 ml per pack , tips small 100 micro liter 1000 numers per pack , tips big 1000 micro liter 1000 numers per pack , grouping and typing antiserum abo3 x 10 ml , anti h sera 10 ml , troponin i rapid card whole blood serum and plasma , hiv rapid card 4th generation 50 test per pack , hbs ag rapid card 50 test per pack , hcv rapid card 50 test per pack , vdrl rapid card 50 test per pack , dengue rapid card ns1 ag anti igg and anti igm , widal rapid test kit 30 test per pack , scrub typhus rapid card anti igg and anti igm , malarial parasite rapid card 50 test per pack , microfilaria rapid card 50 test per pack , leptospirosis rapid card 10 test per pack , aso reagent 20test per pack , ra reagent 20 test per pack , crp reagent 35 test per pack , widal reagent 4 x 5 ml , mantoux reagent ppd 5tu 10tu 10 ml , pap staining kit rapid pap smear kit , coplin jars plastic 60 ml , fixative 95 percentage isoprophanol 500 ml , hematoxylin stain 125 ml , xylene 500 ml , dpx 250 ml , conc hcl 500 ml , sodium metabisulphite 500 gram , potassium dichromate 500 gram , brush for test tube wash small , brush for test tube wash medium , brush for test tube wash large , ph paper plastic container 8 mm width 10 books , portable vein viewing device , sample transport box 20 litre , timer digital , slide tray dry aluminium tray , slide storage box 100 slides storage per box , diamond pencils glass marking pencil , forceps medium size non-toothed forceps , pipette stand , spirit lamp , micro pipette fixed 50 ul , micro pipette fixed 20 ul , micro pipette fixed 10 ul , micro pipette fixed 1000 ul , micro pipette fixed 100 ul , micro pipette fixed 500 ul , micro pipette of various sizes 100 ul to 1000 ul , micro pipette of various sizes 10 ul to 100 ul , test tube racks plastic holds 50mm , test tube racks plastic holds 15 mm , test tube rack 1 point 5 ml , slide tray aluminium tray , neubauer chamber , automa
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign