Web Analytics Made Easy - StatCounter

Chemiluminescence Analyzer Tenders

Get complete information related to latest Chemiluminescence Analyzer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Chemiluminescence Analyzer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Chemiluminescence Analyzer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45715774 Due date: 14 Jul, 202614 Jul, 2026 1.27 Crore
Tender For automated chemiluminescence analyzer , hiv 1 & 2 p24 antigen , anti hcv , hbsag

CTN :44495983 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For corrigendum : tender for fully automated random access chemiluminescence analyzer (reagent rental basis) for the department of transfusion medicine

CTN :45572734 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For abbreviated enit for supply, installation, testing and commissioning of automated chemiluminescence analyzer on reagent rental basis for the department of microbiology and blood bank, skims mch bemina.

CTN :45446505 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For corrigendum : rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have cont

State Government

CTN :45444403 Due date: 26 Jun, 202626 Jun, 2026 90.00 Lacs
Tender For supply, installation, testing and commissioning of fully automated chemiluminescence analyzer on reagent rental basis for screening of infectious agents in donated blood units at blood centre, sir sunderlal hospital, ims, bhu

State Government

CTN :45134796 Due date: 06 Jun, 202606 Jun, 2026 90.00 Lacs
Tender For supply, installation, testing and commissioning of fully automated chemiluminescence analyzer on reagent rental basis for screening of infectious agents in donated blood units at blood centre, sir sunderlal hospital, ims, bhu

Central Government/Public Sector

CTN :45170097 Due date: 11 Jun, 202611 Jun, 2026 50.00 Lacs
Tender For fully automated flash chemiluminescence analyzer, department of microbiology

CTN :44980751 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For corrigendum : supply of fully automated chemiluminescence analyzer

Central Government/Public Sector

CTN :45167167 Due date: 21 May, 202621 May, 2026 NA
Tender For supply of set of four nos of standard calibration gas mixture for dissolved gas analyzer with regulator nozzle fine control 0.5 litres w/c aluminium high pressure canister with fine control needle valve and rubber septum and knob arrangement as spares to draw sample directly from canister using gc syringe.preparation tolerance (plus or minus 20 %) and shelf life 12 months. filling pressure 20 kg/sq.cm.gas composition is as follows: item 1: hydrogen 5 ppm,, methane 5 ppm,, ethylene 5 ppm,, ethane 5 ppm, acetylene 5 ppm, carbon monoxide 50 ppm, carbon dioxide 50 ppm, nitrogen as balance.item 2: hydrogen 500 ppm, methane 500 ppm, ethylene 500 ppm, ethane 500 ppm, acetylene 500 ppm, carbon monoxide 5000 ppm & carbon dioxide 5000 ppm; nitrogen as balance. item 3: hydrogen 700 ppm, methane 700 ppm, ethylene 700 ppm, ethane 700 ppm, acetylene 700 ppm, carbon monoxide 7000 ppm & carbon dioxide 7000 ppm; nitrogen as balance item 4: hydrogen 100 ppm, methane 100 ppm,. ethylene 100 ppm, ethane 100 ppm, acetylene 100 ppm, carbon monoxide 1000 ppm & carbon dioxide 1000 ppm; nitrogen as balance. ]

Central Government/Public Sector

CTN :45014870 Due date: 11 May, 202611 May, 2026 NA
Tender For corrigendum : supply of standard gas mixture for calibration of dissolved gas analyzer 10 ltr capacity aluminum can with nozzle and screw fine control valve on to out let valve, on top of can to obtain required gas flow with regulator 1) 1000 ppm - methane, 2)1000 ppm-ethane, 3) 1000 ppm -ethylene, 4) 1000 ppm-acetylene, 5) 1000 ppm-hydrogen, 6) 5000 ppm-carbon dioxide, 7) 5000 ppm -carbonmonoxide,8) balance - nitrogen. accepted make: spantech(spancan) londen. as per specification attached [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up