Tender For corrigendum : supply of manual call boxes of cast aluminum type , response indicator on surface recessed ms box having two leds metallic cover , fire alarm sounders electronic operating on 24 v dc with sounder card and speaker. , ionisation type smoke detector for detection smoke complete with base and connection. , photo electric type smoke detector for detection of visible smoke complete with base and connection. , thermister control heat detector operating on 24 volts dc complete with base. , microprocessor based main control and indicating panel. , aluminium channel with aluminium cover complete with accessories. , pvc insulated copper conductor cable
Tender For corrigendum : supply of ems repair at bsnl tele bhavan ahmedabad f f - replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair
Tender For non-destructive examination of various equipments and process piping at hwpk site during mta-2025 - ultrasonic flaw detection of weldments on towers, tanks, equipment, nozzles, large dia gas lines and process pipe lines as per standard practice using reputed make ut flaw detector probes by asnt/isnt ut level ii/iii qualified and experienced persons including surface preparation with pre/post cleaning of weldments, interpretation of data and submission of reports., ultrasonic flaw detection of weldments on towers, tanks, equipment, nozzles, large dia gas lines and process pipe lines as per standard practice using reputed make ut flaw detector probes by asnt/isnt ut level ii/iii qualified and experienced persons including surface preparation with pre/post cleaning of weldments, interpretation of data and submission of reports., thickness measurement/mapping with grid marking at identified locations of xu towers/tanks and piping using standard ut thickness gauges and probe by asnt/isnt ut level ii/iii qualified and experienced persons including surface preparation with pre/ post cleaning, interpretation of data and submission of reports., phased array ultrasonic testing/time of flight diffraction of weld joints of exchange unit towers / tanks /pipelines as per standard practice using standard equipment and probes by asnt/isnt ut level ii/iii qualified and experienced persons including surface preparation with pre/post cleaning of weldments, interpretation of data, preparation and submission of reports ., liquid penetrant testing of weldments of heat exchangers, stiffening rings, equipment skirt/saddle supports, equipment nozzles d of xu towers, tanks and weldments of pipe lines (including supply of consumables and dp kit) by asnt/ isnt lpt level ii/iii qualified and experienced persons including surface preparation with pre/post cleaning of weldments and submission of reports, liquid penetrant testing of weldments of heat exchangers, stiffening rings, equipment skirt/saddle supports, equipment nozzles d of xu towers, tanks and weldments of pipe lines (including supply of consumables and dp kit) by asnt/ isnt lpt level ii/iii qualified and experienced persons including surface preparation with pre/post cleaning of weldments and submission of reports, long range ultrasonic testing (lrut) of process liquid piping and large dia gas piping connected to tower and tank with in 1st isolation valve of size from 4 inch nb to 36 inch dia.
Tender For corrigendum : supply of - spares for bhel make critical ht motors at cpp terminal box cover 400kw,fr:1la7566-2p, terminal connector 400kw,fr:1la7566-2p, motor cooling fan 400kw,frame:1la7566-2p, motor fan cover 400kw,frame: 1la7566-2p, brg temp detector 400kw,frame:1la7566-2p, bearing housing set 400kw,fr:1la7566-2p, de outer brg cap,400kw,6.6kv,40096a-401-, end shield set,400kw,6.6kv,40096a40121-8, terminal box cover 385kw,fr:1la7566-2p, terminal connector 385kw,fr:1la7566-2p, motor cooling fan 385kw,frame:1la7566-2p, motor fan cover 385kw,frame:1la7566-2p, mtr btd 385kw,fr:1la7566-2p,bhel, bearing housing 385kw,frame:1la7566-2p, outer brg cap,385kw,6.6kv,40096a40131-7, end shield set,385kw,6.6kv,40096a40131-8, mtr tb cvr 600kw,frame:1la7632-4,bhel, motor cooling fan 600kw,frame:1la7632-4, motor fan cover 600kw,frame:1la7632-4, brg housng 600kw,frame:1la7632-4,bhel, mtr brgcap 600kw,frame:1la7632-4,bhel, mtr es set 600kw,frame:1la7632-4,bhel, motor tb cover 2100kw,frame:1rn7632-4p, term connector 2100kw,fr:1rn7632-4p,bhel, motor fan 2100kw,frame:1rn7632-4p,bhel, motor fan cover 2100kw,frame:1rn7632-4p, motor btds de+nde 2100kw,fr:1rn7632-4p, bearing house 2100kw,fr:1rn7632-4p,bhel, bearing cap set 2100kw,frame:1rn7632-4p, end shield set 2100kw,frame:1rn7632-4p, mtr ex gkt,2.1mw,6.6kv,s.n:40096a40111-9, motor tb cover 225kw,frame:1la7502-2p, motor ter connector 225kw,fr:1la7502-2p, motor fan 225kw,frame:1la7502-2p,bhel, motor fan cover 225kw,frame:1la7502-2p, motor btd 225kw,frame:1la7502-2p,bhel, bearing housing 225kw,fr:1la750-2p,bhel, bearing cap 225kw,frame:1la7502-2p,bhel, end shield set 225kw,fr:1la7502-2p,bhel, motor tb covr 855kw,frame:1la7714-2,bhel, motor cooling fan 855kw,frame:1la7714-2, motor fan cover 855kw,frame: 1la7714-2, bearing temp detector 855kw,fr:1la7714-2, end shield set 855kw,fr:1la7714-2,bhel, t. box cover 4100kw,frame:1rn7716-4,bhel, motor cooling fan 4100kw,frame:1rn7716-4, motor fan cover 4100kw,frame:1rn7716-4, brg temp detector 4100kw,fr:1rn7716-4, end shield set 4100kw,frame:1rn7716-4, heat excr gskt set 4100kw,fr:1rn7716-4, mtr tb cvr,800kw,frame:1la7712-6,bhel, mtr tml cn 800kw,frame:1la7712-6,bhel, motor cooling fan 800kw,frame:1la7712-6, motor fan cover 800kw,frame:1la7712-6, mtr btd 800kw,frame:1la7712-6,bhel, brg housng 800kw,frame:1la7712-6,bhel, mtr brgcap 800kw,frame:1la7712-6,bhel, mtr es set 800kw,frame:1la7712-6,bhel, t.box cover 3050kw,frame:1la7905-4,bhel, terminal connector 3050kw,fr:1la7905-4, motor cooling fan 3050kw,frame:1la7905-4, motor fan cover 3050kw,frame:1la7905-4, brg temp. detector 3050kw,fr:1la7905-4, motor brg hsg set 3050kw,fr:1la7905-4, motor end shield set 3050kw,fr:1la7905-4, motor outer brg cap set 3050kw,1la7905-4, motor nde side sleeve brg assy 855kw, mtr de brg sleeve assy 855kw,1la7714-2, - quantity | 1 - msme exemption | no - startup exemption | no
Tender For (1) repair maintenance of central heating plant, lift and fire alarm system installed at hq artrac shimla (h.p.). (2) moei, repair maintenance of pump set, fire alarm installed at cpnr building (ag office, railway board building, sib dormer building) shimla. (3) moei, replacement of lamps and tubes, fire alarm, epabx and repair maintenance of pump set and diesel generator set at grand hotel shimla. (4) moei, repair maintenance of diesel generator set, sub station and central heating plant at himlok parisar, longwood shimla.subwork/packages:sh:- provision of fire alarm and heat detector testing kit.