Get complete information related to latest Ci Sheet Roof Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ci Sheet Roof Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ci Sheet Roof Repair Tenders.
Tender For inviting rate for construction material as given in the list for the financial year 2026-27 - inviting rate for construction material as given in the list for the financial year 2026-27, hard murrom with spreading, course sand sand, fine sand barman sand, crusher stone duststone dust, 06 mm metal crushed. metal, 12 mm metal crushed. metal, 20 mm metal crushed. metal, 40 mm metal crushed. metal, 90 mm metal crushed. metal, bricks (local)9 x 4 x 3, r.c.c. hume pipe300 mm dian.p.-3, r.c.c. hume pipe450 mm dian.p.-3, r.c.c. hume pipe600 mm dian.p.-3, r.c.c. hume pipe1000 mm dian.p.-3, r.c.c. cement pole2.40 m hight, wire mesh (steel)50x50 mm strengthing 4mm with nut bolt baser, angle iron all size mild steel, winding wire, iron chamber/drain grill (complete spot fitting with labour), corrogated g.i. sheet0.63 mm0.63 mm, cement o.p.c. isi markisi mark 50kg beg, centring shutering with fitting and cartling below plinth level, centring/shutring with fitting & cartingabove plinth level, putty double coat with finishinglabour, roller machine with diesel & operetor, 16 to 18 mm thik plan white marble/green marble/zebra black marble/red marble, 25mm thick kota stone, 16 to 18 mm thick granite stone of any colour and shade, vetrified tiles60 x 60 cm 10mm thick 15:15622, glazed tiles300 x 300 mm 10 mm thick 15:15622, tiles / marble fitting labour charge, pvc floor carpet, w.c. 580 x 440 mm with footrest & p-trap with fittingodisa petarn, w.c. european type with fittingisi marked white solid plastic seat and lideuropean type, w.c. european type with fittingisi marked black solid plastic seat and lideuropean type, chequr tiles with fitting18 to 20mm thick ordnory cement, m.s. tube steel frame febrication work including all fitting labour charge, m.s. angle steel frame febrication work including all fitting labour charge, providing and laying cement concrete m20 grade work with required & equipmentlabour, aluminium fram work complete (glass/acp sheet/grill), jcb machine with diesel and operetor, hydra machine with diesel and operetor, water proofing treatment on roofs of slab by cement slurry mixed with water proofing compound complete, wall painting with plastic emulsion paint of approved paint, removing white or colour wash by scrapping and sand papering complete, distempring with oil bound distamper water proof paint complete, repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq mm including cutting the patches in propper shape, providing & fixing granite bhumipujan / lokarpan patthar with photo and writing work complete, providing ply 19 mm thick, providing carpentar for furniture work, providing and fixing 60 mm thick paver block 30 n/sqmm, brick masonary work with open bhatta complete, water proofing treatment on roofs of slab by asian paint, indigo, etc with water proofing compound 3 layer with crakseal, putty, labuar complete, pvc pipe 3 inch dia 4kg/cm2, pvc pipe 3 inch dia 4kg/cm2 elvo
Tender For supply of ferritic steel sheet 2x1250x2100mm., as per drawing: rdso spec. no. c-k201, grade x2crni12 (409m) table 1&2, heat treatment condition 2b as per table-5., packing instruction:stainless steel sheets, coils and plates:- (a) stainless steel (austenitic & ferritic steel)coils. the coil shall be protected in reasonably good condition to with stand normal handling hazard during transit with the following provision as the barest minimum: i) coil should be wrapped with a layer of water proof paper through out whole length. ii) coil should be wrapped with a layer of biodegradeable sheet. iii) outer & inner of coil should be wrapped with gisheet. iv) side of the coil should be covered with card board sheet. v) after this whole coilshould be wrapped with biodegradeable plastic sheet of suitable thickness. vi) the inner edge of the coil should be protected by gi ring followed by another iron ring. vii) outer edgeof the coil should be wrapped with gi ring. viii) coil should be securely strapped with minium 5 steel bands through the eyes of the coil and minium 3 steel bands on thecircumference of the eye. ix) whole coil should be mounted on wooden blocks for easylifting/stacking. x) the sheets in coil form for thickness 2mm and above shall have: inner dia of coil 450-800mm outer dia of coil 1000-1300mm weight of coil 2.4 - 10 tonnes xi) the sheets in coil form for thickness below 2mm shall have: inner dia of coil 450-650mm outer dia of coil 1000-1300mm weight of coil 5.0 - 10 tonnes. (b) stainless steel (austenitic & ferritic steel plates/sheets) i) the sheets/plates shall be supplied in bundles of optimum weight: 2mt+/-10% & each sheet/plate shall be seprated with a layer of water proof paper, after this the whole bundle should be wrapped with double layer of water proof paper and a biodegradeable plastic sheet of suitable thickness. a metal protection in edges should also be provided. ii) all bundles shall have a minimum of 2 hoops upto 1.2 meter in length and one extra hoop for every additional meter. the bundles shall also be provided with skid (wooden packing under neath) to facilitate handling. mechanical damange & corrosion during transit if any shall be at the cost of supplier. protection procedue: covered in pi [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of ordinary portland cement , stone aggregate 20mm , coarse sand shall , stone aggregate 40mm , rr stone , tmt steel bar 16mm dia , tmt steel bar 12mm dia , tmt steel bar 10mm dia , tmt steel bar 8 mm dia , binding wire 20 gauge 0 point 9mm , shuttering water proof plywood of size 8feet x 4feet and 12mm , nails 2 inch for shuttering , nails 3 inch for shuttering , nails 5 inch for shuttering , quick setting compound make , 2nd class hardwood square section 50mmx50mm length 3 point 0 m , wooden ballies 75mm to 100 mm dia 3m , pbs roll is 1322 to 62 weight min 3 kgs per sqm and minimum length 10 mtr width 1m , bitumen and blown type and 85 or 25 grade , water proofing compound , hdpe film of 400 micron , loop holes of size 600x500mm with a angel iron 50x506mm andiron 40x6 mm covered with 3 mm size 200x50x6mmof 8 mm thick mild steel plate 600x500mm of 75x75mm 100 mm , wooden scantling 3 point 20m long section 100x75mm , steel door of size 900x1800 mm shall be provided as per drawing , lightning conductor made of copper tube 150 cm long x 25mm dia , supply dual edge 8 pin cloth hanger , supply pipe 150mm dia or bukhari outlet dia , supply ms round pipe 20mm dia of medium class for telehphone outlet , pre- painted g aluminum zinc coating sheet 0 point 60mm thickstrength of 550 mpa , 75mm dia pvc pipe , ms plate 10 mm , ms plate 20 mm , shredded rubber 150 mm , ordinary portland cement grade 43 , coarse sand , binding wire 20 gauge 0 point 9mm , nails 2 inch , nails 3 inch , nails 5 inch , quick setting compound , 2nd class hardwood and square section 50mmx50mm length 3 point 0m , wooden ballies 75mm to 100 mm dia 3m long , pbs roll is 1322 to 62 weight min 3 kgs per sqm and minimum length 10 mtr width 1m laid , bitumen and blown type and 85 per 25 grade primer for roof treatment , synthetic enamel paint colour , turpentine oil , loop holes of size 600x500mm angel iron 50x506mm and 45x45x6 mm and flat iron 40x6 mm covered with 2 mm thick size 200x50x6mm flat iron mild steel plate 400x480mm , steel door of size 900x1800 mm shall be provided as per drawing ms angle 50x50x6 mm , lightning conductor made of copper tube 150 cm long x 25mm dia prongs of length 15cm each fixed to copper ball of dia 50mm and 4mm , shredded rubber 150 mm crumb rubber tiles size 500 x 500 x 50 mm , pvc single core 1 point 5 sqmm , pvc single core 2 point 5 sqmm , cable pvc insulated and pvc 1100v , pvc conduit pipe round shape 50 mm dia and 3 point 00 mm , pvc l bend for 20 mm , pvc t 20 mm , pvc square box 4 inch x 4 inch , pvc elbow 20 mm dia , dry wall screw 50 mm , mcb single pole 230v ac and 50 hz and 6 ampc and 10 amp , switch piano flush type15 amp and socket multi purpose 5 or 15 amp piano type with gang box , pvc ceiling rose 2 or 3 terminal , insulation tape 25 mm width 9 mtr , distribution box mcb box 12 way , stainless steel u clamp for 20 mm pvc , isolator 63 amp dp , earthing of building provided using 3 mm dia of size 60cm x 60cm 6mm , pvc t 20 mm for conduit pipe , dry wall screw 50 mm long , mcb single pole 230v ac and 50 hz and 6 ampcand 10 amp , insulation tape 25 mm width 9 mtr long , distribution box 12 way , isolator 63 amp , earthing of building provided using 3 mm dia gi , stone aggregate 10mm to 12mm graded , coarse sand sand shall be clean , stone aggregate 20mm graded , stone aggregate 40mm graded //bid details 2 / 62
Tender For provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti