Get complete information related to latest Circuit Board Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Circuit Board Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Circuit Board Scrap Tenders.
Tender For supplying installation testing and commissioning of laundry equipment in ashadeep narela delhi - supplying installation testing and commissioning of laundry equipment in ashadeep narela delhi - sitc of front loading washing machine with loading capacity of 30 kg dry weight per charge heavy duty , electrically heater inner basket & outer drum stainless steel, micro countroller base cyclic timer for auto- reserve, auto- timer & auto digital temperature control, water- inlet valve drain valve complete with control panel, & electric motor for wash, driver through pulleys & v- belts and control panel operator on 3ph, 415 v, 50 hz, a.c. supply operation cycle 30 to 40 mintutes complete connection etc as required, sitc of hydro extractor machine direct- driver self- balance with automatic electromangnetic dc injection brake system having capaciy of 30 kg per charge with auto -timed top loading vibration less innner basket and outer drum stainless steel complete with specially designed electric motor and control panel operator on 415 v,3 phase , 50 hz ac supply . operation cycle 5 to 10 mintes complete connection etc as required., sitc of drying tumbler machine front loading open pocket, electrically heater with loading capacity of 30 kg . per charge complete with micro controller base cyclic timer for auto timed & auto - reserver, auto digital temperature control, fitted with control panel , one motor each for driver and blower double walled glass wool insulated outer body mild steel with inner basket stainless steel, self lint screen , v belt driver waster air exhaust etc operates on 415 v, phase 50 hz ac supply . operation cycle 40 to 60 mintes complete connection etc as reqd, supplying and drawing following sizes of frls/hffr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required.a) 3 x 4 sq. mm, b) 6 x 4 sq. mm, supplying and fixing of following capacity, 240/415 volts, 10ka/15ka c series mcbs suitable for lighting and other loads of following poles in the existing mcb db complete with connection, testing and commissioning etc as reqd.a) 40a, 10 ka , fp mcb (415v), b) 63a, 10 ka , fp mcb (415v), supplying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size complete as required.a) 4x 16 sqmm, b) 4x 25 sqmm, supplying, installation, testing & commissioning of led surface mounted batten light of following body material and construction as per is : 10322 with driver (replaceable) as per the requirement with driver efficiency >85%, operating voltage ac 140- 270 volt, frequency 50/60 hz, operating temp range -5 c to 40 c, internal surge protection of 2.5 kv with short & open circuit protection, thd 10%, p. f. 0.95, ip20, cri >80, flicker free, (flicker shouldbe below 5 %), life time (led, driver & electrical circuitry), of minimum 50000 burning hours with 70% of initial lumen maintained till life ends, cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin), sdcm(standard deviation colour matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard. manufactures word mark/ name engraved/ embossing/ screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 105 120 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90 c). powder coated die cast /extruded aluminium body (thickness > 1.20 mm)a) 40 watt, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in th
Tender For corrigendum : supply of igbt heatsink mounted single module 600 amp 1200 v , pca operator logic board 1 phase 240 vac ups for hipulse 2x125 kva ups system , transformer sensing copper 3 phase 60 va 415 v380 v220 vby31.5 v class f for 2x125kva ups system , pca igbt driver board 7400 for 2x125kva hipulse ups system , pca unsync transfer board for hipulse 2x125 kva ups systemmodel7400m , thyristor heat sink mounted module 190 amp average 300 amp rms 1600 v for 2x125kva ups system , thyristor heat sink mounted module 540 amp average 850 amp rms 1400 v semipack 5 for 2x125kva ups system , fan axial 4 inch 230 vac 1 phase 50 hz 95 cfm 2600 rpmpart code 181000016000for 2x125kva ups system , pca high voltage interface board 1 phase 240 vacpart code100208011021for hipulse 2x 125 kva ups system , fan, centrifugal 230 vac 1 phase 50 hz 335 48 cfm 2500 rpmpart code0000000e5009 , transformer control copper 1 phase 60 va 220 230 240 vby17 0 17 v part code291606011001for 2x125kva ups system , pca ups logic board 1 phase 240 vacpart code100221021031for hipulse 2x125 kva ups system , pca rectifier driver board 7400m for 2x125kva hipulse ups system , current transformer bar primary sensing 100 1 5 va class 1 moulded resin with lug fitting , hall effect sensor 100 amp 0 to 300 amp 4 v open loop 15 v panel mounting hta , fan axial 8 inch 230 vac 1 phase 50 hz 530 cfm 2700 rpmpart code 181000084000 for 2x125 kva ups system , lcd display module for ups make db power electronics pvt ltd sunlike lcd 20x2 , pca dc dc power supply board 2811 03025401part code100204011023for hipulse 2x 125 kva ups systemmodel 400m , pca panel synoptic mimic board for 2x125 kva hipulse ups make emerson network power i pvt ltd ) /bid number : gem/2026/b/7084201 * /dated: 07-01-2026 & & / bid document 1 / 19
Tender For supply of automatic star delta starter panel in 16 swg steel sheet enclosure of size 600x750x200 mm,three phase 415 v, ac, load current 70 amp, 50 c/s, 40 hp, light gray spray painted, panel wiring of powersection with 1x35 sq mm multi stranded pvc insulated copper conductor 1.1 kv grade, comprising of - 01 no hlvd2 voltage sensing relay, 01 no, qt-100 time switch, 01 no hour meter, 01 set phase sequence indicator, 6-way connector, 01 no toggle switch 15 amps, 01 no ammeter (0-200a), 01 no voltmeter (0-600v),01 set ct coil 100/5 & 15va, 03 nos led indication lamps, 01 no selector switch (ass), 01 no selector switch (vss), 03 nos cut out 6a for control, 03 nos toggle switch 6a for control, 2 set green/red push button for on/off, 01 no kwh meter type ct 2m - 200/5 ct operated, 03 nos ml- 4 contractor with 2no & 2nc, 1 no bi-metallic over load relay (40-70a) type mn x r4, 01 no electronic timer (0-30 sec), 01 no motor protection relay, 01 no mccb type dh- 200/35ka, 01 no time delay relay (0-30 minute). make- l&t, c&s and abb or similar [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply, installation, testing & commissioning of igbt based constant current/constant voltage static battery charger/discharge panel