Get complete information related to latest Cleaning Service Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cleaning Service Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cleaning Service Tenders.
Tender For providing drainage cleaningservice work for all internal and external colony roads, surrounding areas of internal and external roads, and water supply work in all the commercial hubs and all the colony areas covered under colony sector no.o. i to vi at ukai.
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For day to day maint of b/r nature related complaints like door repair, internal water supply related complaints, window glass/ jallies, water tank cleaning and other allied works in domestic area at afs hasi mara
Tender For auction sale of others - u/s scrap abandoned quarter block no 71 (a-h) 8 unit type ¿i not fit for rly use. bricks 141109.00 nos approx, brick bats- 166.00 cum approx , u/s sariya, angle, xpm gate, window , fencing gate and gi pipe approx 3034 kg , u/s pvc tank, pvc cistern, ptmt tap,pillar tap approx 10 kg, u/s wooden door frame and panel/shutters approx 230 kg location ¿located at 02 bn rpsf rajhi colony under the jurisdiction of sse/w/gkc custodian - sse-w-gkc condition-1 ¿ the above lot has already been declared abandoned by the competent authority. 2 ¿ dismantling of structure by concerned purchaser on his own risk and cost, if any loss will be occur during dismantling process whole responsibility liable by purchaser. 3- the lot is on estimated basis , hence any item may be less or more 4-all useful and unusable materials on the site will have to be removed by the purchaser at his own expense. 5 ¿ after removing all the material from the site, leveling dressing and cleaning activity perform by the concern purchaser by his own risk and cost. 6- road is available 7- the lot does not include us rail and electric poles. loading by purchaser labour, delivery by lot, gst-18% ,hsn code-72044900, tcs-1%, allocation-20714208
Tender For auction sale of others - u/s scrap abandoned quarter block no 70 (a-l) 12 unit type ¿i not fit for rly use. bricks 214850.00 nos approx, brick bats- 252.50 cum approx , u/s sariya, angle, xpm gate, window ,fencing gate and gi pipe approx 3886 kg , u/s pvc tank, pvc cistern, ptmt tap,pillar tap approx 15 kg, u/s wooden door frame and panel/shutters approx 190 kg location ¿located at 02 bn rpsf rajhi colony under the jurisdiction of sse/w/gkc custodian - sse-w-gkc condition-1 ¿ the above lot has already been declared abandoned by the competent authority. 2 ¿ dismantling of structure by concerned purchaser on his own risk and cost, if any loss will be occur during dismantling process whole responsibility liable by purchaser. 3- the lot is on estimated basis , hence any item may be less or more 4-all useful and unusable materials on the site will have to be removed by the purchaser at his own expense. 5 ¿ after removing all the material from the site, leveling dressing and cleaning activity perform by the concern purchaser by his own risk and cost. 6- road is available 7- the lot does not include us rail and electric poles. loading by purchaser labour, delivery by lot, gst-18% ,hsn code-72044900, tcs-1%, allocation-20714208
Tender For corrigendum : selection of agency for integrated door to door collection,segregated transportation,user charges collection,digital collection,road sweeping and strom water drain cleaning in municipal commitee katra and identified kda areas - selection of agency for integrated door-to-door collection, segregated transportation, user charge collection, digital monitoring, road sweeping and storm water drain cleaningservices in municipal committee katra and identified kda areas