Tender For corrigendum : supply of ring seal , ring local. , wear ring , hose arsy , ring wear , floor mat , element , o ring housing , dust indicator , dust seal , hose centryfugal oil filter , hyd hose , fuel filter , element filter eye , air clener bend , oil seal , retainer hose , hose assy suction , hose tank side , hose high pressure , hose , hose , 95 lth 1 2 oip pipe , 75 lth 316 op pipe
Tender For corrigendum : purchase of sports physiotherapy lab equipments - focused shockwave therapy, the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high power laser thera, it should have class iv laser solid-state it should have inbuilt protocol for different indications laser wavelength should be 808nm & 980nm for 18w it should provide laser power up to 0.500mw to 18w pick power 18w (808 nm wavelength for 8w & 980 nm for 10w) the unit should have 7 touch screen facility for use the unit should operating mode should be cw (continuous) or pulsed the unit supply with attachments: scanning laser applicator 500-550mw (class 3b) the unit supply with small and large attachments 1cm and 5cm should be provided to cover different areas the unit supply with dila (deep intratissue laser adapter) supply 2 pairs of laser protective goggles to be supplied warranty 2-year class iv laser therapy is a recent modality that is used to treat pain and promote healing of muscular tissue. the class iv deep intratissue laser therapy machine is european ce approved and is clinically proven to reduce inflammation, reduce pain and increase overall range of motion in a short therapy cycle. it is being used widely all musculoskeletal pain conditions, soft tissue injuries and a wide range of other clinical indication cdsceo device registration certificate unit supply with original trolley, combination therapy machine with vaccum, the unit should be 7 colour display with touch panel treatment encyclopaedia electrodiagnostic i/t curve number of built-in programmes 204 number of user programs 150 number of compatible 2 ultrasound heads electrotherapy parmenter 2 channel electrotherapies max constant current inpatients circuit cc mode- 10. galvanic current 40 ma diadynamic, pules, current 60 ma interferential, kotz, current, unipolar sing surge -100ma tens and sp-tens current 140 ma tonolysis 100 ma microcurrents 1000 a max. voltage in patients circuite (cv mode)-140 v treatment timer 30s 60 min. the unit ultrasound head amplitude- max. 8w for 4cm head working in continuous mode the unit ultrasound head max 12w for cm working in pules mode ultrasound therapy parameter operation frequency- ultrasound head with acoustic working frequency of 1mhz & 3.5mhz with the effective radiation area 4cm effective radiating area- 4cm max ultrasound intensity -continuous /pulse mode 2/3w/cm frequency in pules mode- 16 hz/48 hz/100 hz 24. duty factor in pulse mode 5-75%, step 5% thermal effect 2-year warranty ce european or fda usa certified with iso medical device certifications cdsceo device registration certificate unit supply with original trolley and gel bottle stand and vacuum cup stand with electrode, low frequency electro magnetic therapy, 7 colour touchscreen peration mode: program/manual a sensory indicator of the magnetic field activity- magnetic stripes treatments in dual mode setting the frequency range of the magnetic field with an accuracy of 0,01 hz using the on- screen keyboard illustrated encyclopa
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposable syringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr
Tender For supply of spare parts of scania - hose part no 225586, hose part no 225373(561700), oil pressure sensor part no 373811(374338), hose part no 211402, pressure indicator part no 235000, hose m erf, 450mm part no 811276, rubber bushing part no 205271, bushing part no 202591, inspection glass part no 258915, o ring part no 804870, hose part no 139915, hose part no 241805, gasket part no 139030, hose part no 283136, hose part no 231842, hose part no 1102304, hose part no 297407, hose part no 297394, hose part no 217657, water temp monitor part no 371081, hose, feeding part no 249619, cover part no 242858, gasket part no 812420, filter part no 141721, gasket part no 143816, dust cover part no 190335, spacer part no 363737, rubber damper part no 40607, o ring 34, 2 x 3 part no 294548, rubber steering part no 294771, seal ring part no 214309, seal ring part no 164900, o ring part no 304426, gasket part no 387216, o ring 49, 2 x 5, 7 part no 390546, gasket part no 387236, sealing part no 234112, sealing part no 234113, gasket part no 387274, o ring 9, 1 x 1, 6 part no 390547, filter insert part no 214631, gasket part no 387297(122090), seal ring part no 254635, o ring 79, 2 x 5, 7 part no 810983, o ring part no 368033, gasket part no 387225, gasket part no 387260, gasket part no 387247, gasket part no 387223
Tender For corrigendum : tender for supply of cartridge filter elements , 930 mm long hose , 250 mm long hose , 630 mm long hose , 900 mm long hose , 1650 mm long hose , conductivity display (meter with sensor) , fan cover , fan motor , kit wear parts , chi 2-40 neck ring retnr p-65 , oil pan , wick long tab , female adaptor , male adaptor , flexible pipe-pu8/9 , 3/8 elbow connector , pressure switch , pressure switch , flow switch , illumination push button whie , control transformer , lp hose 15mm ip 500mm long with 1/2 inch bsp(m) both sides , lp hose 50 mm id 500 mm long with 2 inch bsp(m) both sides , lp hose 50 mm id 410 mm long with 2 inch bsp(m) both sides , lp hose 63mm id 500mm long with 2 1/2 inch bsp(m) both sides , pressure gauge (0-100) , pressure guage(0-100 bar) , charging plug , hp connection feed/brine , mechanical seal for filter pump , 6 mm bolts for filter pump , end cover , gasket , k26repair kit (for prefilter/ filter pump) , sleeve gasket , split pin , 2 way ball valve set of 2 , ball valve abs 3 way d20 , taper bush for hp pump motor , taper bush , ro 200 (2tpd&4tpd) prefilter/filter pump motor bearing (de & , crt prefilter/filter pump motor bearing (nde) , o ring kit hp pump , zinc anode , seal kit for hp pump , valve kit for hp pump , oil seal , anode plug , seal retainer , motor v belt pulley 02 grooved , oil seal crankshaft , oil seal crank case , straight connector 3/8 , permeate male elbow , tee pu4 , oil sight glass , dolomite , membrane cleaner 11 , membrane cleaner 22 , membrane cleaner 33 , membrane solution 44 , s.s. jubilee clips 22 mm to 30 mm , lip seal dt module , o ring distance fitting outside , o-ring(pos. no. 412) for speck pump npy 2051 , high pressure flexible hose , h.p hose feed inlet/brine outlet , high pressure hose module outlet , brine r/w h.p. flexible hose , rubber hose 20mm , av mount akcc 85m , h.p pump driving belt(set of 2) , hp pump driving belt set , victaulic couplers 1.1/4 , belt spanner , socket d.i module , sleeve gasket , neck ring p 45 , neck ring for retainer p 65 , shaft seal p 105 , sleeve gasket , mechanical seal p 105 , sleeve gasket p37 , mechanical seal , anod plug , bearing (hp pump) , valve kit , seal kit , anode plug , seal kit , seal.oil , crankshaft , rod connecting assy , o-ringcrankcase cover , rod plunger , seal oil crankcase , retainer seal 2 pc , wick lg tab , adapter male , spacer w/coil springs , spacer v-packing , manifold discaharge , head distributor 3-4 air connection , o ring for head distributor assembly , o ring for head distriutor , o ring hp connection , groove ring gasket flange , abs solvent cement 100 gm , ball valve 2 way 20mm , abs ballvalve 3 way , connector 1 1-4 bsp (f) x 1 1-4 vivt , victualic coupling 1 , victaulic couplers 1.1/4 , pipe clamp 32 mm (2 bolt) , permeate male elbow , pvc tee pu9 , oil sight glass/ st. conn. 1/4 (m)xpu4 , connector straight , flange with bsp threading , smcv spindle & seat , pressure switch , control transformer , pressure gauge( 0-10 bar) , highpressure gauge 0-100bar , temperature indicator , flowmeter 40-400lph with magnetic float , flow switch , rubber hose 20mm , lp hose - 50mm id 410mm long with 2 bsp(m) both sides , lp hose - 50mm id 500mm long with 2 bsp(m) both sides , lp hose - 63mm id 500mm long with 2 1-2 bsp(m) both sides , lp hose - 75mm id 500mm long with 3 bsp(m) both sides , hp hose module out , hp flexible hose , hp hose 3/8 idx1/2unf-n&fx1000l , ss316 , hp hose of module in , taper bush 1610 20 mm bore , taper bush for motor pulley , filter & permeate pump bearing 2z 6201 , av mount akcc 85m , av mount , sq.pad sc8/50c(450x450x8mm) , jubilee clips for d 25 , jubilee clip 2a (38 mm-50mm) , pressure guage( 0-100 bar) , t-branch pu9 , h.p. connection - feed/brine , high pressure transmitter 4 to 20 ma (pt60) , pressure switch , hp pump driving belt set , abs service kit hp pump inlet ro 1530 , abs service kit for cartridge filter ro 1530 , ss service kit rosm 03 tpd , se