Web Analytics Made Easy - StatCounter

Clinometer Scrap Tenders

Get complete information related to latest Clinometer Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Clinometer Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Clinometer Scrap Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40398381 Due date: 13 Jun, 202513 Jun, 2025 NA
Tender For empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint. # th

State Government

CTN :40435240 Due date: 29 May, 202529 May, 2025 NA
Tender For request proposal for supplying various equipment, chemicals, standard reference microbial cultures, glasswares/ plasticwares and general items in 9 numbers of district level water testing laboratories of jharkhand a-dumka zone - refrigerator- ( 265 litre approx., double door ),make & model: branded ( is standard), analytical balance-( 4digit), weighing capacity of 220g, externally calibrated by nabl accredited lab/agency with calibration certificate, make & model: branded) ( is standard), ph meter-(measuring range ph0.0-14.0), make & model: branded ( is standard), hot plate with magnetic stirrer-(power: 2000 watt approx., operating volts: 230a15 volts a/c), stirring capacity: 50-1500 rpm, capacity of stirrer: 2 litre, plate size: 18.4x18.4 cm(approx.), make & model: branded, bacteriological incubator-digital construction -double walled construction outer body made of mild steel powder coated & inner body made of stainless steel, insulation : glass woll insulation between two walls. inner size : 18" x 18" x 24", rating watts 750, no. of shelves 3, capacity 120 ltrs, temp range- 5 c - 60 c accuracy +/- 0.5 c, temp controlled by : controlled by pid micro process controller with dual display. selves : with g.i. wire mesh selves, door : 2 door inner acrylic door to view sample & outer metal door with air circulation motor with blower for uniform temperature throughout chamber. heater : special nichrome heater designed for long life & saving of power consuption. thermometer type : electronic with digital display. make & model : branded ( is standard), laminar air flow chamber(biosafety cabinet)-external dimensions (lxwxh) in inches and mm:40 x34.25 x56.7, (1020 x870x 1440) work area dimensions: 34.45 x24 x22.52 (857x610x572) material of construction: galvanised iron sheet with epoxy polyester thermosetting powder coating of 80 microns, 1.5mm thickness/stainless steel grade 304,1.2mm for ss modelsbody finish: glossy off white colour for gi powder coated table top: 1.2mm ss 304 sheet of matt finish pressed on 25mm solid nuwud board side glass: 6mm float glass encased in stainless steel channels front door: frameless gas spring loaded swinging type polycarbonate 6mm thickness wheels and levelling lugs: pu solid wheels with plated brackets and metallic powder coated design: front bottom loading pre-filters or completer work area with stainless steel including hepa grill cleanliness class: iso standard 14644-1- class 5 stages of filtration: a.pre-filters= 10 with an efficiency of 90 % washable hdpe media in frp pu coated frame b.mini pleat hepa filter encased aluminium frame with an efficiency of 99.995% motor blower assembly: variable speed mtor mounted on pu coated frp blowers with aluminium powder coated impellers velocity: 100 fpm at 6 from face of the filter noise level: less than 60db at 1 meter from the face of the equipmenthepa filter grill: stainless steel grills duly perforated and polished electrical specifications: a. switches and speed controller: microprocessor controlled feather touch switch panel b. fluorescent lighting: 18 watt. c. chokes for lighting: 18 watt d. ultraviolet lighting: 1.5 feet length g15t8, 15 watt power consumption: 250 watts lighting: greater than 800 lux power supply: 230v,50hz power supply, single phase 5 amperes power cord accessories: gas burner, gas/vacuum cock ( is standard), autoclave -vertical autoclave size 14" dia x 22" ht, rating in watts 3000, capacity of 52 ltrs complete s.s with foot lifting arrangement used for sterilization under saturated steam pressure at 15psi with double walled units with inner chamber made of thick stainless steel and outer chamber made of s.s.lid is made of thick gauge stainless steel with pressure gauge steam release valve, and safety valves. with foot lifting arrangement. with s.s. basketaccessories:1. digital temperature indicator cum controller with timer -1 no.2. water level cut off-1no.3. pressure cut off switch-1no. ( is stan

State Government

CTN :40071789 Due date: 02 Jun, 202502 Jun, 2025 NA
Tender For corrigendum : providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above

Central Government/Public Sector

CTN :40241465 Due date: 27 May, 202527 May, 2025 NA
Tender For supply of air compressor spares - neuron ii controller , oil filter eelment , air filter eelment , coup. elemet rotex , air lube plus , element separator , auto drain , single ph. preventer

corporations/Associations/Others

CTN :40229296 Due date: 26 May, 202526 May, 2025 NA
Tender For supply of automatic burette , glasswares burette pipette volumetric flask measuring cylinder etc , hot air oven digital thermal indicator , glass thermometer incubator , hot plate analog thermal indicator , muffle furnace digital temp controller , analytical digital balances , weight box , loose weight , ph analyzer digital display , de mineralized water unit digital conductivity meter , compressor for icp instrument pressure gauge and switch , argon gas regulators pressure gauge and switch , reactor block digital temperature controller
 Loading, Please wait...

Connect us via What's Up