Get complete information related to latest Co Analyzer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Co Analyzer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Co Analyzer Tenders.
Tender For calibration of digital multimeter fluke (8508a) sr. no. 237066716 , calibration of hv probe 40kv fluke sr. no. 19990010, 20590008 , calibration of multi product calibrator fluke(5522a) sr. no. 2584901 , calibration of microwave/counter/analyzer tektronix (mca3027) sr. no 195960 , calibration of signal generator , calibration of decade boxes(l, c, r) , calibration of standard(l, c, r) , calibration of hvps , calibration of hygrometer , calibration of esd
Tender For corrigendum : supply of automatic testing equipment - auto density meter , camc auto density meter , stabinger viscometer , camc stabinger viscometer , emulsion bath , camc emulsion bath , foaming test low temperature , camc foaming test low temperature , flash point apparatus coc , camc flash point apparatus coc , ftir for pib , camc ftir for pib , uv visible spectrophotometer , camc uv visible spectrophotometer , kf coulometer , camc kf coulometer , edxrf , camc edxrf , pour point and cloud point apparatus , camc pour point and cloud point apparatus , total acidbase number , camc total acidbase number , auto cold cranking simulator ccs , camc auto cold cranking simulator ccs , particle count analyzer auto nas , camc particle count analyzer auto nas , auto color comparator , camc auto color comparator , auto oxidation stability , camc auto oxidation stability , breakdown voltage , camc breakdown voltage , tan delta , camc tan delta , tensiometer , camc tensiometer , gassing tendency , camc gassing tendency , auto viscometer by astm d445 , camc auto viscometer by astm d445 , auto pmcc flash point analyzer , camc auto pmcc flash point analyzer
Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a
Tender For improvement work of supplying and fixing submersible ultra heavy duty dredging vertical pump set to inlet wetwell, trash rack, total coliform analyzer and installation of macerators of 150mld stp at v.valley, uwtp under jha funds coming under aee(wwm-stp)v.v-1 sub dvn. (2nd call)
Tender For open e tender is being invited for supply and installation including reagents/ kits for automated coagulation analyzer in central lab, rims, ranchi. - equipment in central lab, equipment including ups and other accessory to run the equipment, reagents/ consumables/ controls/ calibrator/ others as per cprt for pt/ inr test, reagents/ consumables/ controls/ calibrator/ other as per cprt for aptt test, cmc rate for 3rd year, cmc rate for 4th year, cmc rate for 5th year, cmc rate for 6th year, cmc rate for 7th year, cmc rate for 8th year