Tender For corrigendum : supply, installation, commissioning and maintenance of electronic weighing machines at fair price shops and bihar state food & civil supplies corporation limited godowns in the state of bihar
Tender For corrigendum : providing of custom bid for services - comprehensive contract for manning of face-to-face enquiry counters, manual/passenger address system (pas), coachguidancesystem (cgs), train display boards and other related work across stations, at 15 stations over morada..
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to
Tender For auction sale of depot miscellaneous scrap - condemned old released unserviceable unrepairable & codal/workable life completed various type of television, coachguidancesystem, train indication board, digital clock. qty= 258 nos, weight= 2.870 mts (glass= 750.46 kg, ferrous= 966.67 kg, copper= 27.27 kg, plastic/non ferrous= 1125.6 kg) . for custodian information ss-11 no. sse/t/jbp/2025/01 dt. 11/03/2026. ds-8 note no. 045212 dt. 11/03/2026. mode of delivery by actual weight only. ((remark- 1. sale condition "as is where is basis" & uniform sale condition for e-auction is applicable. )
Tender For comprehensive annual maintenance contract of partronics make central data controller unit, coachguidancesystem, platform data communication hub, at a glace display board, single line display board, and gps based clock installed at maba, askn, rta and shrn for a period of 5 years.
Tender For comprehensive annual maintenance contract of m/s santosh enterprises make central data controller unit, coachguidancesystem, platform display board, at a glace display board, single line display board and gps based clock installed at sci, bhs-4, baq, bina, guna, svpi for a period of 5 years.
Tender For provision of coachguidance display boards and train information display boards at 11 number of abss stations of delhi division of northern railway and balance work in c/w provision of coachguidancesystem at nno, ssb, nur, bvh, & passenger amenities (telecom) at newly constructed platform at anand vihar railway stations and ipis auto announcement, tidb etc at stations where train handling facility is to be started due to station redevelopment of ndls station.
Tender For providing of customized annual maintenance contract/cmc for pre-owned products - comprehensive of annual maintenance contract of train information display board system and coachguidancesystem installed at dee at pf no-2,3&4 and fdb railway station at 2 platforms of delhi division for two years; comprehens..
Tender For corrigendum : selection of system integrator for supply, installation with client application and maintenance of electronic point of purchase (epop) devices at purchase centres for food and civil supplies department, uttar pradesh