Web Analytics Made Easy - StatCounter

Coal Cutters Tenders

Get complete information related to latest Coal Cutters Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Coal Cutters Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Coal Cutters Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :45406322 Due date: 08 Jun, 202608 Jun, 2026 13.47 Lacs
Tender For maintenance of bt roads cc roads storm water drains (catch pit repairs) and attending other complaints for 6 months (i.e., may 2026 to october 2026) under vijaya nagar colony division no.143 masabtank circle no.34 gz ghmc (item no.1)

corporations/Associations/Others

CTN :45406333 Due date: 08 Jun, 202608 Jun, 2026 13.47 Lacs
Tender For maintenance of bt roads cc roads storm water drains (catch pit repairs) and attending other complaints for 6 months (i.e., may 2026 to october 2026) under ahmed nagar division no.144 masabtank circle no.34 gz ghmc (item no.2)

corporations/Associations/Others

CTN :45410838 Due date: 08 Jun, 202608 Jun, 2026 13.47 Lacs
Tender For maintenance of bt roads cc roads storm water drains (catch pit repairs) and attending other complaints for 6 months (i.e., may 2026 to october 2026) under mallepally division no.147 masabtank circle no.34 gz ghmc (item no.4)

corporations/Associations/Others

CTN :45410840 Due date: 08 Jun, 202608 Jun, 2026 13.47 Lacs
Tender For maintenance of bt roads cc roads storm water drains (catch pit repairs) and attending other complaints for 6 months (i.e., may 2026 to october 2026) under shanthi nagar division no.145 masabtank circle no.34 gz ghmc (item no.3) (reserved for scs reservation only)

Central Government/Public Sector

CTN :45392353 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For supply & installation of ohe power presence/absence indicator for during pit line maintenance activities. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45375193 Due date: 20 Jun, 202620 Jun, 2026 NA
Tender For maint and repair of street lights security lights and solar lights and its connected items including repair to lt distribution network at mh and 41 arty div under ge mh and rh khadki - taking down old unserviceable lt ug cables of size upto 50 sq mm from trenches / poles / ducts etc complete all as specified and directed., supplying, laying, jointing, commissioning and testing xlpe insulated screened pvc bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade confirming to is-7098 (part-i-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugs of appropriate size, pvc sleeve etc complete all as directed by engr in -charge for following sizes . make :- polycab/havells / gloster / finolex note :- earth work , bricks , riddled earth , gi pipe for protection of cable will be measured & paid under relevant items of schdule . , 50 sq mm 3.5 core ., 35 sq mm 3.5 core, 25 sq mm 3.5 core, 16 sq mm 4 core., 10 sq mm 2 core, 6 sq mm 2 core, excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation of poles stays laying of electric cables, pipes etc and getting out in soft/loose soil complete all as specified and directed., ditto item no 3 but in hard/dense soil., removing excavated material soil to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed, returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed., material and labour for riddled earth for cushioning to under ground electric cable including spreading , levelling and hand punning complete all as directed. note - punned thickness shall only be measured & paid ., material and labour for road cutting/foot path and making good with pcc 1:3:6 type c-2 ( using 40 mm graded stone aggregate ) of 150 mm depth complete all as specified and directed., supply and laying un-reinforced precast concrete cable cover lv, type i, flat, size 250mm x 150mm x 40mm for under ground cable all as specified and directed., supply and laying gi tubes light grade, galvanized, 40 mm bore in repair ,laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed, ditto item no -10 but 80 mm bore., material and labour for plain cement concrete (pcc) 1:3:6 type c2 using 40mm graded stone aggregate for making foundation of pole/stay assembly complete all as specified and directed., material and labour for plain cement concrete (pcc) 1:3:6 type c1 using 20mm graded stone aggregate for making copings of poles etc complete all as specified and directed. ., material and labour for earthing complete with galvanised steel earth plate eletrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5mtr below normal ground level, connected to the earth lead wire 4.0 mm dia (gi wire) size, by means of bolts, nuts, check buts and washers of galvanised iron, earth lead wire 4.0 mm dia protected by provision of gi medium grade pipe 15 mm bore including provision of 40 mm thick cover of rcc (1:2:4) 20mm graded stone aggregate re-inforced with xpm (weight not less than 4 kg per sqm) and frame of angle iron 40x40x3 mm with lugs 02 nos and with 6 mm dia ms bar handle made to shape, gi light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exe 50 mtr and removal of surplas soil to plate no 3 of ssr 2009 part-i and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed. , material and labour fo

CTN :45138827 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For bid to ras supply of s and f of ring main system for wss - supplying laying jointing commissioning and testing 100mm bore centrifugally cast spun ductile iron pressure pipe with spigot and socketed ends class k7 confirming to is 8329 or 2000 as per atc , supplying laying jointing commissioning and testing 150mm bore centrifugally cast spun ductile iron pressure pipe with spigot and socketed ends class k7 confirming to is 8329 or 2000 as per atc , supply and fix valve reflux with by pass arrangement 100mm 4 inches dia , supply and fix foot valve confirming to is 4038 100mm 4 inches dia , supply and fix valve sluice flanged of class 1 point 6pn 100mm 4 inches dia , supply and fix valves sluice flanged of class 1 point 6 pn 150mm 6 inches dia , supplying installing testing and comissioning of centrifugal pump electric driven capacity not less than 25 lps discharge at 60 metre head in load as per atc , supply laying testing cable xlpe insulated screened pvc bedded galvanized steel strip wire armd electric powercable hd 1100v grade stranded aluminium conductor size 70 sqmm 3 point 5 core , supply laying testing cable xlpe insulated screened pvc bedded galvanized steel strip wire armd electric powercable heavyduty 1100v grade stranded aluminium conductor size 10 sqmm 4 core , supplying installing testing and commissioning of outdoor type factory made crca sheet thickness 3 point 15mm platform mounted lt panel board to accommodate as per atc , supplying installing testing and commissioning of indoor type factory made crca sheet thickness 2mm platform mounted lt panel board to accommodate as per atc , supply install test commission centrifugal openwell submersible pump cap 10hp singlephase discharge range 740 to 200lpm head range 35 to 54m suction x discharge pipe dia 65x50mm as per atc , supply and fix cast iron air valves with two air outlets 80mm dia bore and fixing up in ) /bid number : gem/2026/b/7514655 * /dated: 08-05-2026 & & / bid document 1 / 21 & & ' ' /item category cast iron water supply mains , excavation in tranches not exc 1 point 5m wide n exc 1 point 5m depth over exc 10sqm on plan and n exc 1 point 5m in depth for foundations shafts wells cesspite mainholes pier holes as per atc , returning filling in including spreading laveling watering and well ramming in layers n exc 25cm in soft or loose soil complete all as specified and directed by engr in charge , removal of excavated soil material to a distance not exc 50m or depositing where directed at a level not exc 1 point 50 metre above th staring point complete all as specified as per atc , boring of hole under road pavement hardstanding by trenchless technology using ultra sounding technique nec machine incl hdpe pipe 150mm dia suitable for 0 point 4mpa working pressure , cutting existing ci or di pipe line of 150mm and inserting tee of size 150 x 150 x 150mm for taping complete all as specified and directed note tee 150 x 150 x 150mm paid separetly in di special , cutting existing ci or di pipe line of 150mm and inserting tee of size 150 x 150 x 100mm for taping complete all as specified and directed note tee 150 x 150 x 100mm paid separetly in di special , di or ci special such as tee bend collar tail piece and other fitting as required , earthing of poles and other machinery or equipment using 4mm gi wire as earthing lead and ms galvanized plate of size 60cm x 60cm x 6mm as earth electrode , demolition and diasmanttling of concrete in ground floor and pavings n exc 15cm thickness , m and l of cement concrete b 2 1 colon 2 colon 4 40mm graded aggregate 100mm thickness , m and l for contruction of brick masonry valve pit in repair of inter size 90x90x90cm incl nec exc earth work in soft or loose soil brick work plastering white wash pcc coping ms frame as per atc , m and l for contruction of brick masonry valve pit in repair of inter size 120x120x90cm incl nec exc earth work in soft or loose soil brick work plastering white wash pcc coping ms frame

Central Government/Public Sector

CTN :45284367 Due date: 25 Jun, 202625 Jun, 2026 NA
Tender For supply of 16 watt 48 volt led (matrix type) pit light luminaries as per specification attached as annexure-a [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

State Government

CTN :45249557 Due date: 29 May, 202629 May, 2026 50.00 Lacs
Tender For annual rate contract for providing new water service connection with material under division balotra - providing household tap connection as per technical specification and approved drawing as per relevant is code (amended up to date) from hdpe/upvc/di/ac/ms/gi pipe line up to consumer meter/premises by using pp mechanical integrated saddle with inbuilt flow control valve made out of ss316 designed for 5 lpm discharge at 0.5 bar pressure , not exceeding the flow of 7 lpm at 2 bar and a compression elbow, moulded in single piece/ fusion welded (complete job) including digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including gm full-way valve (is:778 mark) or wheel valve and specials with 20 mm nominal dia mdpe pipe pe 80 pn 16 as per iso 4427 / 20 mm nominal dia ppr-c (three layered) pipe pn16 sdr 7.4 (is:15801:2008) (isi mark) and above ground level using ppr-c pipe with standard ppr fittings/ gi pipes in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . the service line should be laid at least 45 cm below ground level. note: road cut and restoration is not part of this item and paid separately. for connection with 20 mm dia mdpe/ppr-c pipe length up to 05 mtr. rate is exclusive of gst., road cutting for house hold service connection in minimum trench width wherever road crossing is required. road cutting of cement concrete,wbm, black top etc. of all thickness shall be done by using a concrete cutter machine keeping minimum trench width and restoration of the road with cement concrete with pcc m-10 and cc m-30 grade as per specification and direction of engineer in charge.(06 meter) rate is exclusive of gst., add extra over item no 1.21, 1.22 & 1.23 for providing 20 mm pe 80 pn 16 as per iso 4427 mdpe pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. rate is exclusive of gst., road cutting charges for pit of size 1.0x1.0 mtr for providing connection dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by cc cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. (0.30 cum) rate is exclusive of gst., road restoration charges for pit of size 1.0x1.0 mtr for providing connection providing and laying in position cement concrete m10 grade nominal mix 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. measurement for cc work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work. (0.10 cum) rate is exclusive of gst., providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. measurement

corporations/Associations/Others

CTN :45192961 Due date: 26 May, 202626 May, 2026 5.76 Lacs
Tender For regular operation and maintenance of water supply scheme with material at industrial area, residential colony and commercial complex jhunjhunu phase-i and ii - item rate, regular operation of tube wells installed with pumping machineries with round the clock monitoring, including complete repair and maintenance of pump set with cost of material and labour required for repairing/rewinding, lowering and un-lowering etc.the scope of work also includes repair and maintenance of panel board, main switches, kit-kates, electric connections, service cableand submersible cables inclusive of cost of material and labour required for uninterrupted functioning of tube wells.it is also inclusive of complete repair and maintenance of pipes connected with pump and motor, its replacement, if required, regular upkeeping of log book etc. and other works as mentioned in tender document / scope of work complete in all respect and as directed by engineer in-charge., regular operation and maintenance of pump houses located at wss complex/complexes.the work includes operation of distribution line main valves for daily supply of water of the industrial area at supply times specified by corporation. regular operation of pump house installed with existing centrifugal / monoblock pump / motors, with round the clock monitoring, including complete repair and maintenance of pump sets, connecting suction/delivery pipes jointing material, panel, main switches, kit-kates, electric connections, service cable including cost of material and labour required for repairing / rewinding, removal and replacement etc. for uninterrupted functioning of electric panels and pump sets with regular up-keepment of log books, repair of leakages in pump glans and ms/ci/ac pipeline system inside of wss campus complete, regular chemical dosing in cwr maintaining general cleanliness at pump house and wss campus complete in all respect as directed by engineer in-charge., repair & maintenance of existing distribution / rising main pipe line system consisting of ac pressure pipeline /pvc/upvc/hdpe/ci/ di lines for maintaining smooth water supply in area covered under the scope of work.the scope of work includes timely repairing of leakage in all existing distribution / rising main pipeline of all sizes by digging out suitable size of pit in soft & loose soil / hard soil including cutting of bituminous / cement concrete / wbm / wmm surface at any site of work at no extra cost.it is also inclusive of cutting of pipe ends, fixing of pipe pieces with jointing material to make repair leak proof and refilling the pit / trench by excavated soil by ramming it at all sides of pipes & upto ground level. contractor will do dewatering at his own level by making necessary arrangements, if required. contractor will usetheir own t&p and jointing materials, however the pipe line and sluice valves (if required) etc. shall be provided by the corporation but the contractor shall have to deposit the damaged material in riico store. but no additional payment shall be made on account of any material or transportation charges.
 Loading, Please wait...

Connect us via What's Up