Tender For supply of cctv camera full setup sl. no. description specification qty. 1 ip bullet camera 5 mp, outdoor, ir-enabled, poe compatible 05 nos. 2 ip dome camera 5 mp, indoor, ir-enabled, poe compatible 05 nos.3 hard disk drive (surveillance grade) 4 tb capacity 02 nos. 4 poe switch 8-port gigabit poe switch 02 nos. 5 network switch 16-port gigabit managed/unmanaged switch 01 no. 6 ups system online ups, 3 kva with minimum 120 minutes backup including batteries 01 set 7 power cable 2 sq.mm copper cable 180 mtr. 8network & associated cabling materials cat-6 cable, hdmi/vga cable, patch cords (3 m), rj-45 connectors, flexible pipes, cable ties, fasteners, clamps, saddles, junction boxes and other installation accessories as required 9 pvc/gi conduits suitable size for cable protection and routing approx. 500 feet 10 display unit 75-inch 4k uhd commercial grade led display, 24 x 7 operation rated (sony/samsung/lg or equivalent approved make) 01 no. all cameras shall support h.265/h.264 compression, onvif protocol and poe operation. hdds shall be surveillance-grade continuous recording for 30 days display unit shall be commercial-grade and designed for continuous operation. all cables, connectors and accessories shall be of reputed make and conform to relevant standards. the contractor shall provide all minor materials and accessories not specifically mentioned but required for successful completion of the work. the system shall be supplied, installed, tested and commissioned as a complete turnkey solution. [ warranty period: 24 months after the date of delivery ] ]
Tender For supply of set of welded partition frame for bangladesh ac chair car coaches.note: make/manufacturer of raw material shall be m/s jsl or m/s sail., as per drawing: mp25paraccbang version 2, packing instruction: `packing condition of set of partition frame and procedure to achieve best possible protection during transportation: 1. surface preparation: - thoroughly clean the components to remove any dirt, grease or contaminants - apply a protective film, such as pvc or laser film or bubble sheet, to shield surfaces from scratches and environmental factor. 2. packing materials: - wooden crates: construct sturdy wooden cage tailored to the component's dimensions. - steel strapping: utilize rust-proof steel straps to securely bundle components, preventing movement during transit. 3. moisture barrier: - incorporate moisture-proof materials, such as plasticfilm or water proof ability paper, to guard against corrosion. 4. componentarrangement: - place components on wooden pallets or within custom-designed supports to distribute weight evenly and prevent deformation. - ensure that no part of the component extends beyond the protective packaging to avoid exposure to potential damage. 5. securing the components: - use steel straps or ropes to fimly anchor the components within the wooden crate, minimizing internal movement. - for added stability, employ bracing or cushioning materials, such as foam pads or corrugated inserts, to fill voids and absorb shocks. - hardware items to be suitably packed separately inside the crate. 6. labeling and documentation: - clearly label each package with essential information, including pl no. specifications, details of each set with qty. and also keep one copy inside ot the crate, weight, handling instructions and firm's & destination details. 7. loading onto trailer/lorry/truck/transport: - strategically position the packaged components within the truck/suitable to maintain balance and prevent shifting during transit. - secure the packages to the container's structure using lashing ties or additional bracing as needed. 8. final inspection and sealing: - conduct a thorough inspection to verify that all components are securely packed and that packaging materials are intact. [ warranty period: 30 months after the date of delivery ] ]
Tender For ss 316 self locking type cable tie with polyester/ nylon coating - 200 mm (l) and 0.1 mm to 5.00mm ( , ss 316 loose piece head (buckle) for custom length cable ties width 11.1 mm to 15 mm , ss 316 self locking type cable tie with polyester/ nylon coating - 350 mm (l) and 7.1 mm to 9 mm (w)
Tender For supply of m l for point wiring with pvc insulated unsheathed single core multi stranded copper conductor 1 5 sqmm 1100 volts grade cable frls passing through pvc casing caping including accessories , one 3 pin switch socket combination 5 amps on the same board with other switches 28 points , one 3 pin switch socket combination 5 amps independent 30 points , one bell point controlled by one push button 4 points , all as per item no 1 above but with 2 5 sqmm cable for one three pin 15 amps socket out let controlled by one switch 18 points , s f modular switch 1 module single pole one way 6 amp conforming to is 3854 and isi marked complete all as direcred 84 nos , s f modular switch 1 module single pole one way 16 amp conforming to is3854 and isi marked complete all as direcred 18 nos , s f ceiling rose with earth terminal connection 3 terminal pvc polycarbonate isolated body of size 60x50mm 26 nos , s f modular socket 6a 3 pin 2 module conforming to is 1293 2019 and isi marked complete all as direcred 58 nos , s f modular socket 6 16a 3 pin 2 module conforming to is 1293 2019 and isi marked complete all as direcred 18 nos , s f modular pvc gang box screwless of 6 module for mounting of modular switches and sockets including blank plate for blank module 8 nos , all as per item no- 8.00 above but of modular pvc gang box 4 module 22 nos , all as per item no- 8.00 above but of modular pvc gang box 3 module 38 nos , all as per item no- 37.00 above but of modular pvc gang box 2 module 5 nos , sf modular white cover plate with frame 6 module 8 nos , sf modular white cover plate with frame 4 module 22 nos , sf modular white cover plate with frame 3 module 38 nos , sf modular white cover plate with frame 2 module 5 nos , supply and fix led aluminium housing of batten fitting 20 watt 240v 4ft cdlnw comprises of aluminium extruded channel in thermally conductive material with decorative end cap , s f mcb db spn conforming to ip 43 ik 09 with acrylic double door 12 way complete with din rail neutral and earthing bar 11 nos , s f mcb spn 63 amp 10 ka 230 volt c curve type 11 nos , s f mcb single pole 20 amp 10 ka 230 volt c curve type 81 nos , s f cable pvc insulated pvc sheathed armoured frls 1100v grade 2 core 6 sqmm stranded copper conductor electric cable laid on wall roof duct complete with proper saddling , supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole mcb of capacity 20 amp, 240 volts complete all as specified and directed 26 nos , m l for pvc insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross-sectional area 50 sq mm 3.5 core 140 rm , s f vtpn db 8 way suitable for flush mounting and surface mounting with 250 a copper busbar for each phase with 2 neutral bar 2 earthbar and cable ties , s f mccb tpn 100 amp icu 16 ka 415v with magnetic release complete all as specified and directed 8 nos , s f mccb 4 pole 160 amp icu 36 ka 415v with magnetic release complete all as specified and directed 2 nos , m l for snap- on trunking system with cover angles bends and all accessories and fitting of size 50x130 mm with 2- compartment fixing on wall complete all specified and directed 90 rm , s f modular bell push switch 1 module single pole one way 6amp isi marked 4 nos , s f in replacement with modular electric bell ding dong ac 230v single pole 4 nos //bid details 2 / 28
Tender For supply of set of welded partition frame for non ac bangladesh coach. note: make/manufacturer of raw material shall be m/s jsl or m/s sail., as per drawing: mp25parnabang version 3, packing instruction: `packing condition of set of partition frame and procedure to achieve best possible protection during transportation: 1. surface preparation: - thoroughly clean the components to remove any dirt, grease or contaminants - apply a protective film, such as pvc or laser film or bubble sheet, to shield surfaces from scratches and environmental factor. 2. packing materials: - wooden crates: construct sturdy wooden cage tailored to the component's dimensions. - steel strapping: utilize rust-proof steel straps to securely bundle components, preventing movement during transit. 3. moisture barrier: - incorporate moisture-proof materials, such as plastic film or water proof ability paper, to guard against corrosion. 4. component arrangement: - place components on wooden pallets or within custom-designed supports to distribute weight evenly and prevent deformation. - ensure that no part of the component extends beyond the protective packaging to avoid exposure to potential damage. 5. securingthe components: - use steel straps or ropes to fimly anchor the components within thewooden crate, minimizing internal movement. - for added stability, employ bracing or cushioning materials, such as foam pads or corrugated inserts, to fill voids and absorbshocks. - hardware items to be suitably packed separately inside the crate. 6. labeling and documentation: - clearly label each package with essential information, including pl no. specifications, details of each set with qty. and also keep one copy inside ot the crate, weight, handling instructions and firm's & destination details. 7. loading onto trailer/lorry/truck/transport: - strategically position the packaged components within the truck/suitable to maintain balance and prevent shifting during transit. - secure the packages to the container's structure using lashing ties or additional bracing as needed. 8. final inspection and sealing: - conduct a thorough inspection to verify thatall components are securely packed and that packaging materials are intact. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of cat 6 ethernet cable , rj 45 connectors , patch chords 2 mtrs , patch chords 5 mtrs , patch chords 10 mtrs , patch chords 15 mtrs , hdmi switcher 3 in 1 out with remote controller , hdmi switcher 5 in 1 out with remote controller , hdmi splitter 1 in 4 out , hdmi splitter1 in 3 out , nylon cable ties 12 inch long , nylon cable ties 4 inch long , vga cable for pc 1.5 mtrs , vga cable for pc 15 mtrs , hdmi cable 6 ft , hdmi cable 3.3 ft , usb c to usb c cable , wireless presenter , hdmi to vga adaptor , hdmi to vga cable 20 ft , hdmi to vga 50 ft , hdmi to vga adaptor with 3.5 mm audio jack , usb c hub 4 in 1 vga to hdmi adaptor
Tender For supply of set of partition frame for lsdd amrit bharat 3.0 ( (note- colour scheme is as per design letter no md48161 dated- 15/05/2026 ), as per drawing: mp26pfgsab3.0 version 0, packing instruction: `packing condition of set of partition frame and procedure to achieve best possible protection during transportation: 1. surface preparation: - thoroughly clean the components to remove any dirt, grease or contaminants - apply a protective film, such as pvc or laser film or bubble sheet, to shield surfaces from scratches and environmental factor. 2. packing materials: - wooden crates: construct sturdy wooden cage tailored to the component's dimensions. - steel strapping: utilize rust-proof steel straps to securely bundle components, preventing movement during transit. 3. moisture barrier: - incorporate moisture-proof materials, such as plastic film or water proof ability paper, to guard against corrosion. 4. component arrangement: - place components on wooden pallets or within custom-designed supports to distribute weight evenly and prevent deformation. - ensure that no part of the component extends beyond the protective packaging to avoid exposure to potential damage. 5. securing the components: - use steel straps or ropes to fimly anchor the components within the wooden crate, minimizing internal movement. - for added stability, employ bracing or cushioning materials, such as foam pads or corrugated inserts, to fill voids and absorb shocks. - hardware items to be suitably packed separately inside the crate. 6. labeling and documentation: - clearly label each package with essential information, including pl no. specifications, details of each set with qty. and also keep one copy inside ot the crate, weight, handling instructions and firm's & destination details. 7. loading onto trailer/lorry/truck/transport: - strategically position the packaged components within the truck/suitable to maintain balance and prevent shifting during transit. - secure the packages to the container's structure using lashing ties or additional bracing as needed.8. final inspection and sealing: - conduct a thorough inspection to verify that all components are securely packed and that packaging materials are intact. [ warranty period:30 months after the date of delivery ] ]
Tender For general-payyannur block panchayat-sgsy marketing centre installation of electrical equipments-project no-so188/26 - wiring, 90.2.1.1:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frls pvc insulated stranded single core copper conductor cable 650v grade, including providing switch board main and continuous earthing with no.14 swg bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (rohs compliant modular accessories).single control light point with 6a, plate ceiling rose - short point, 90.2.1.2:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frls pvc insulated stranded single core copper conductor cable 650v grade, including providing switch board main and continuous earthing with no.14 swg bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (rohs compliant modular accessories).twin control light point with 6a, plate ceiling rose - short point, 90.2.1.6:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frls pvc insulated stranded single core copper conductor cable 650v grade, including providing switch board main and continuous earthing with no.14 swg bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (rohs compliant modular accessories).combined plug point with 6 a, 5 pin plug socket controlled by 6 a, switch in the same switch board as that of light points, od466063/2025-2026:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frls pvc insulated stranded single core copper conductor cable 650v grade, including providing switch board main and continuous earthing with no.14 swg bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc c