Web Analytics Made Easy - StatCounter

Cold Storage Room Tenders

Get complete information related to latest Cold Storage Room Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cold Storage Room Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cold Storage Room Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45700588 Due date: 02 Jul, 202602 Jul, 2026 4.19 Lacs
Tender For 1) repair of reverse osmosis system 1000 litre per hour with chiller, atm and other allied work. (gram panchayat) 2) providing, supplying, and commisioning of reverse osmosis drinking water system ( anganwadi -5nos ) 3) providing, supplying, and commisioning of reverse osmosis system 25 lph capacity( z p school -3nos ) 4) providing supplying and comissloning of reverse osmosis system 250 lph per hour capacity ( z.p school gaothan )

Central Government/Public Sector

CTN :45713851 Due date: 25 Jul, 202625 Jul, 2026 55.00 Lacs
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole

CTN :45713398 Due date: 13 Jul, 202613 Jul, 2026 96.8 Thousand
Tender For supply, installation, testing and commissioning of additional cold storage room adjacent to the existing cold storage room along with annual maintenance contract for 3 years at annadanam, sri pat, tiruchanoor. (part-a: supply, installation, testing and commissioning & (part-b: annual maintenance contract of cold storage).

CTN :45690610 Due date: 04 Jul, 202604 Jul, 2026 17.37 Lacs
Tender For supply of water dispenser hot and cold , water cooler , refrigerator double door , air cooler big , air cooler medium size , air cooler small , pedestal fan , wall fan , ice box , cold storage room with stabliser

State Government

CTN :45655498 Due date: 02 Jul, 202602 Jul, 2026 5.05 Lacs
Tender For repair maintenance of eandm services at rao tula ram memorial hospital, jaffarpur, new delhi. (sh comprehensive maintenance of bluestar make mortuary units (cold storage room).)

Central Government/Public Sector

CTN :45403836 Due date: 30 Jun, 202630 Jun, 2026 50.00 Lacs
Tender For corrigendum : repair maintenance of ac plant infrastructure replacement of defective condenser tubes chiller tubes hot water generator system alongwith other accessories at naval station karanja

Central Government/Public Sector

CTN :45598119 Due date: 30 Jun, 202630 Jun, 2026 8.22 Lacs
Tender For supply, installation , tesgting , commissioning of cold storage room (equipment) in the old boys hostel at central university of tamil nadu, thiruvarur - coold storage room size (18l *11w * 9h) feet, supply of puf panels, door, refrigeration unit, control panel with accessories, installation charges of puf panels, doors & refrigeration units, labour charges for loading, unloading, labour charges for copper piping laying work, n2 pressure test, leak test, leak arrest, again n2 pressure hold, vaccuming, gas charging and commissioning of the unit, additional refrigeration pipe with accessories, transport charges, supplying and fixing of following sizes of water pipe of upvc ( sch 40) conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required., 25 mm, electrical work, supplying and fixing of following ways surface/ recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer ) as required ., 12 way (4 + 36), double door (power & ups), providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, ics=100% icu and operational voltage 690v etc. as required., 100 a, 16 ka,tpmccb , supplying and fixing following rating, four pole, 415 v, mcb in the existing mcb db complete with connections, testing and commissioning etc. as required., 63a, supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth,metal enclosed plug top along with 30 a"c" curve, tpmcb in sheet steel enclosure,on surface or in recess, with chained metal cover for the socket out let and complete with connections, testings and commissiong etc required, 4 x 16 sq. mm + 2 x 6 sq. mm earth wire (incommer for power & ups line to db box)

Central Government/Public Sector

CTN :45596533 Due date: 08 Jul, 202608 Jul, 2026 45.00 Lacs
Tender For comprehensive maint of 3 x 39 tr chiller unit cooling tower condenser chilled water pipeline ahus at inhs sanjivani and comprehensive maint of 60 tr chiller unit installed at fats at naval base kochi repair replacement of dampers and certain miscellaneous r

Central Government/Public Sector

CTN :45347377 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For corrigendum : providing of repair and overhauling service - ductable air conditioner; repair of 40 tr water chiller vanguard; yes; buyer premises

CTN :45351064 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - water filter ro 50 liter per hour chiller 100 liter per hour motor half hp water tonkey 500 liter accessories set; office space; buyer
 Loading, Please wait...