Get complete information related to latest Collection Tank Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Collection Tank Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Collection Tank Tenders.
Tender For construction of leachat collectiontank , sanitary landfill , weighing scale and pumping machinery at municipal solid waste management of karanja municipal council tq karanja dist washim under sbm (u) 2.0
Tender For construction of underground leachate collectiontanks including connection with existing drain network at mrfs 3brd and industrial area phase 1 chandigarh.
Tender For corrigendum : supply of deluge system equipment for msb unit for nrep - a. deluge water spray systems (mvws system + water curtain system + hvws system)cs deluge valve with dry pilot trim & electric release trim, horizontal inlet & horizontal outlet, without skid, ul/fm approved, complete with dry pilot trim with test, alarm & drain devices, local deluge valve control station (dvlcs) (1 no. per dv), pressure transmitters (02 nos per dv.), 3/3 way sil2 certified intrinsically safe solenoid valve-24v dc (1 no. per dv), pressure gauges (03 nos. per dv), air filetr regulator (afr)(1 no. per dv), air vessel of adequate capacity (1 no. per dv), etc. in compliance with the scheme shown in attached "technical data sheets for fire fighting & safety equipment (tk-1p21a-sa-dat-0001)".the deluge valves shall be supplied with the trim and associated instruments duly assemblied with the deluge valve and with suitable packaging to avoid damage during transportation. the upstream strainer, block valves and by-pass valve including the pipes connecting to these items are not in bidders scope of supply.all items shall be suitable and certified for zone 1,iic,t3 area classification. all electrical and instruments shall be certified for intrinsically safe (ex-ia) and solenoid valve shall be certified to explosion proof (ex-d). all instruments and enclosures (junction boxes/ cabinets/panels/ accessories) in field shall be dust proof and weather proof with ip-67., 200 mm nb, 150 mm nb, 100 mm nb, 80 mm nb, mvw spray nozzle with 1/2" mnpt end connection, moc - stainless steel, ul / fm listed, (with inbuilt strainer): size 15 nb, mvw spray nozzle with 1/2" mnpt end connection, k factor-18, spray angle 120 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-18, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-18, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-22, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-22, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-26, spray angle 120 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-26, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-30, spray angle 120 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-30, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-30, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-35, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-35, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-41, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-51, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-51, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-79, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., quartzo
Tender For corrigendum : purchase of biochemistry lab equipments - fully automatic biochemistry analyzerthroughput: 200 photometric tests/hour & 400 tests/hour with ise (optional)reagent positions: 50 cooled reagent positionssample type: whole blood, serum, plasma, urine, csf otherreading volume: 180 lsample volume: 2-70 l (adjustable in 0.1 l)reagent volume: 10-300 l (adjustable in 1 l)light source: halogen lampon board laundry: 6 stage cleaning, 2 stage drying with cuvette validation stepcalibration type: linear, non-linear, multipointprogrammable parameters: default system pack parameters + upto 10 user defined parametersdimensions and weight: ergonomic design and light weight., fully automatic hematology analyzerthroughput-up to 80 samples per hourdimensions and weight ergonomic design and light weighttest mode-cbc, cbc+diffdata storage capacity-up to 100 000 resultscommunication-lan port supports hl7 protocolpower requirement-a.c. 100-240 v, less than or equal to 300 va, 50/60 hzoperating temperature-15 to 30 degree celsiusoperating humidity-30-85%air pressure70-106 kpa, fully automatic immunoassay analyser random assay (hormone analyser)instrument name: immunoassay analyserusage/application-clinicalplate format-random assaydetection method-luminescenceparameters-blood alcohol contentautomation-fully automaticuser input-touchassays-diabetes, thyroid, cardiac, vit d, fully automatic electrolyte analyser-analysis time: 60 second per sample parameters- na , k , cl or ca2+no. of parameters 3 simultaneously90 luser inputs 5 colored touch screen displayelectrode type- sturdy electrode (facility to refill the solution)connectivity 2 usb port, rs232, lisdata storage- 10,000 patient results & 10,000 qc results for 3 levelssample identification- alphanumeric sample idqc management- tri-level quality control, l j plots of last 30 dayscalibration- 2 point calibration on every 4 hours1 point with every samplepower - 100 240 v, 50/60 hz (self adjusting)printer - inbuilt thermal printerroom temperature -15 30 c / 60 90 fhumidity- 85%dimensions and weight - ergonomic design and light weight, centrifuge machine along with 500 prp test tubes (double spin)parameter- neya-16 max speed (rpm)- 15000max rcf (g)- 21000max capacity (ml)- 4 x 175acceleration profiles- 10deceleration profiles- 10display-- multi-color lcdno of programmes- 10 (protected)timer- 30 sec to 99 min & continuous modeergonomic design and light weightsupply - 220v, 50 hz, 1 phasecan be used for extracting prp, autoclavekey features- high-pressure vessel: a high-pressure vessel designed to withstand high temperatures and pressures- temperature control: precise temperature control to ensure effective sterilization- timer and controls: easy-to-use timer and controls for convenient operation- safety features: multiple safety features, such as automatic shut-off and overheat protection, to prevent accidents and ensure safe operationconstruction and materials- stainless steel: a durable stainless steel construction to withstand high temperatures and pressures- insulation: high-quality insulation to ensure efficient heat retention and energy savings- door and seals: a secure door and seal system to prevent steam escape and ensure effective sterilizationperformance specifications- temperature range: 121 c to 134 c.- pressure range: upto 30 psi- cycle time: 15-60 minutes- sterilization capacity in liters or cubic feetsafety standards- compliance with regulations: compliance with relevant regulations, such as asme, fda, and iso standards- automatic safety devices: automatic safety devices, such as overheat protection and low-water cut off, to prevent accidents and ensure safe operation- interlocks: interlocks to prevent door opening during operation and ensure user safetyadditional features- data logging: optional data logging capabilities to track temperature, pressure, and cycle data- printed records: optional printed records of cycle data for documentation and quality control- val
Tender For inviting percentage rate tender for construction of compost shed facility, contraction of weigh bridge and construction of collectiontank at kotma processing plant under ulb shahdol as per nit and estimate.
Tender For corrigendum : work of cleaning and removal of naturally deposited materials from monsoon drains of control rooms and machine hall premises and cleaning and removal silt from fire tank, seepage water collectiontank in escape tunnel an silt arrester tanks at phps