Get complete information related to latest Communication Module Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Communication Module Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Communication Module Tenders.
Tender For internal and external face lifting & tower side development and repairing & painting of damaged fencing at akashwani fm transmitter, bailadila (c.g.).
Tender For corrigendum : procurement of 33 kv & 11 kv 3- phase 4 wire with 0.5 s, ct-pt operated trivector consumer smart meter with built in communicationmodule as per is 16444 part 2 with latest amendment
Tender For corrigendum : supply installation commissioning and maintenance of ht generator smart meter 0.2s class d4 category with pluggable 4g communicationmodule with dual sims (1 e-sim 1 physical sim) hes and facility management services for 5 years - supply, installation, commissioning and maintenance of ht generator smart meter 0.2s class d4 category with pluggable 4g communicationmodule with dual sims (1 e-sim, 1 physical sim), hes and facility management services for 5 years
Tender For corrigendum : supply installation commissioning and maintenance of ht consumer smart meter 0.2s class d3 category with pluggable 4g communicationmodule with dual sims (1 e-sim 1 physical sim)hes and facility management services for 5 years - supply, installation, commissioning and maintenance of ht consumer smart meter 0.2s class d3 category with pluggable 4g communicationmodule with dual sims (1 e-sim, 1 physical sim), hes and facility management services for 5 years
Tender For procurement of spares of m/s yil make hydrogen gas density analyzer system for ph ii at sgtps, mppgcl, birsinghpur - hydrogen gas density sensor model: gd40t detector unit along with compatible pressure transmitter for pressure compensation supply: 100 to 240 v ac, 24 v dc output: 4 to 20 ma dc sample gas: hydrogen gas flow: 0.1 to 1 l/min ambient temperature: -10 to 60 oc humidity: 5 to 95% rh process connection: 1¼ npt (f) electrical connection: 1½ npt (f) enclosure: nema type 4x fm explosion proof and intrinsically safe area classification: zone-1, zone-2 gas group: group-i, iia, iib bin code: 832-49-492-689-01, hydrogen gas density convertor unit model:- gd402t-a-e-e, pressure transmitter model:- ejaf3 oil filter, rota meter (flow meter) work portion, expert servicing, calibration of m/s yil make h2 purity analyzer installed in unit no 4 ph-ii, sgtps, mppgcl, birsinghpur (4 days)
Tender For corrigendum : supply of smart energy meters with head end system services in gift city - 1200009630: 1p2w 240v 10-60a cl-1.0 smart meterdesign, engineering, manufacturing, inspection & testing at manufacturers works before dispatch, supply and delivery at destination (at gift store) of ac whole current 1 phase 2 wire, isi marked, 1.0 class accuracy, 10-60 a smart energy meter with dlms protocol & bidirectional communication facility & remote connect/disconnect switch. the meter shall communicate with head end system (hes) on any one of the communication technologies mentioned in is:16444 part 1 compliant with nbiot communicationmodule fall back to 2g, as per the requirement of the utility for measurement of import and export active energy (kwh) with initial and sustained accuracy of class 1.0 for solidly earthed system with balanced and unbalanced loads having power factor in the range of zero to unity (lagging/leading). the meter shall be compatible to common meter reading instruments and other associated instruments & software for remote reading as per requirements given in this specification, 1200009631: 3p4w 240v 10-100a cl1.0 wc smart meterdesign, engineering, manufacturing, inspection & testing at manufacturers works before dispatch, supply and delivery at destination (at gift store) of ac whole current 3 phase 4 wire, isi marked, 1.0 class accuracy, 10-100 a smart energy meter with dlms protocol & bidirectional communication facility & remote connect/disconnect switch. the meter shall communicate with head end system (hes) on any one of the communication technologies mentioned in is:16444 part 1 compliant with nbiot communicationmodule fall back to 2g, as per the requirement of the utility for measurement of import and export active energy (kwh) with initial and sustained accuracy of class 1.0 for solidly earthed system with balanced and unbalanced loads having power factor in the range of zero to unity (lagging/leading). the meter shall be compatible to common meter reading instruments and other associated instruments & software for remote reading as per requirements given in this specification, 1200009632: 3p4w 240v -/5a cl0.5s ct smart meterdesign, engineering, manufacturing, inspection & testing at manufacturers works before dispatch, supply and delivery at destination (at gift store) of 3 phase 4 wire, isi marked, 0.5s class accuracy, fully static lt current transformer (ct) operated smart energy meter with dlms protocol & bidirectional communication facility. the meter shall communicate with head end system (hes) on any one of the communication technologies mentioned in is:16444 part 2 compliant with nbiot communicationmodule fall back to 2g, as per the requirement of the utility for measurement of import and export active energy (kwh) with initial and sustained accuracy of class 0.5s for solidly earthed system with balanced and unbalanced loads having power factor in the range of zero to unity (lagging/leading). the meter shall be compatible to common meter reading instruments and other associated instruments & software for remote reading as per requirements given in this specification, 1200009630: 1p2w 240v 10-60a cl-1.0 smart meterdesign, engineering, manufacturing, inspection & testing at manufacturers works before dispatch, supply and delivery at destination (at gift store) of ac whole current 1 phase 2 wire, isi marked, 1.0 class accuracy, 10-60 a smart energy meter with dlms protocol & bidirectional communication facility & remote connect/disconnect switch. the meter shall communicate with head end system (hes) on any one of the communication technologies mentioned in is:16444 part 1 compliant with nbiot communicationmodule fall back to 2g, as per the requirement of the utility for measurement of import and export active energy (kwh) with initial and sustained accuracy of class 1.0 for solidly earthed system with balanced and unbalanced loads havin