Get complete information related to latest Commutator Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Commutator Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Commutator Spares Tenders.
Tender For corrigendum : stripped stator of hitachi hs-15250a tm, along with cutting of lugs and repair of pe & ce side.scope of supply as per plw/hitachi-mf/stripping,rev-1,dated 25.04.2026 asper specification no.4tms.095.036(rev-1) & drawing no. 10p.702-107,alt-v. [ warranty period: 12 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35
Tender For providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : annual rate contract for complete stator rewinding of vpi 3.3 kv ht motor with new coils of class f insulation and other additional repair works of 11kv and 3.3kv ht motors of 2x600mw units at katpp jhalawar
Tender For corrigendum : annual rate contract for complete stator rewinding of vpi 3.3 kv ht motor with new coils of class f insulation and other additional repair works of 11kv and 3.3kv ht motors of 2x600mw units at katpp,jhalawar
Tender For corrigendum : providing of custom bid for services - 200153327-job contract for complete rewinding & repair work of ht motor stator and rotor of ntpc kanti
Tender For corrigendum : supply of various electrical items at kstps, kota- supply of 3 phase, 415v lt motors for unit #1 to 7 at kstps, kota. , supply and retrofitting of oltc of unit auxiliary transformer-4b at kstps, kota. , supply of conveyor carrying idler frame & carrying idler frame troughing trainer for conveyor system in chp area. , supply, installation, testing & commissioning of vaccum type gaseous chlorinator system capacity up to 20kg/hr with all accessories for pre treatment plant clarifer-iii for u# 6 & 7 of kstps, kota , supply of submersible dewatering/ mud pumps for cw, bcw & dmcw area of kstps, kota , supply of middle collectors (laterals/intrabed distributors) for strong acid cation vessels of dm plant, stage-li, kstps, kota , supply of various electrical items at kstps, kota , supply of portable and trolley mounted fire-extinguisher of different capacities for first-aid fire fighting system (extinguisher) installied at kstps, kota , supply of valves at kstps, kota. , supply of misc. rubber items at kstps, kota. , repair/machining of components of turbine & auxiliaries of unit 1 to 7 of kstps, kota , online helium leak detection test of condenser vacuum zone of unit # 1 to 7 (stage i to v) of kstps, kota , day to day joinery works inside & outside plant site, kstps, kota , capital, routine & breakdown maintenance of c&i instruments and equipments of stage-i to v, analyser, dm plant, clarifier, ics and cctv systems at kstps,kota , annual rate contract for 6.6kvvpi and non vpiht motor rewinding from 175kw to 4000 kw with new coils of insulation class fand other additional works of stator and rotor