Web Analytics Made Easy - StatCounter

Compact Light Tenders

Get complete information related to latest Compact Light Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Compact Light Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Compact Light Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :41324064 Due date: 02 Sep, 202502 Sep, 2025 NA
Tender For corrigendum : supply of bracket fan 225 mm sweep, 110 v ac conforming to is:6680-92 with annexure-h (december 2005) issued by rdso. the fan base, motor body and bracket shall conform to icf drg. no. icf/sk-7-6-179 with elegant, compact, light weight aluminium body, anti corrosive and frp blade. the fan shall have ball b earings at both the ends with skf/nbc ball bearing. the guard shall be crashworthy design to drg. no.icf/s k 7-6-158 col.ii alt.c. the over all diameter of the guard shall be suitably altered in accordance with the sw eep of the fan. fan should be completely powder coated. the goose neck bracket shall be of stainless steel with on-off toggle switch and wago type connector suitable for 2 pole connection. the weight of the fan sh all not be more than 3 kgs. [ warranty period: 30 months after the date of delivery ]

Central Government / Public Sector

CTN :41454326 Due date: 16 Aug, 202516 Aug, 2025 NA
Tender For supply of bracket fan 225 mm sweep, 110 v ac conforming to rdso specification no. is:6680-92 with annexure-h [december 2005] for rc fan issued by rdso lr.no.qe/6.5.1 dated 10/03/2006. the fan base, motor body and bracket shall conform to icf drg.no. icf/sk-7-6-179 with elegant, compact, light weight aluminium body, anti corrosive and frp blade. the fan shall have ball bearings at both the ends with skf/nbf ball bearing. the guard shall be crashworthy design to drg.no.icf/sk 7-6-158 col.ii alt. g. the overall diameter of the guard shall be suitably altered in accordance with the sweep of the fan. fan should be completely powder coated. the goose neck bracket shall be of stainless steel with on-off toggle switch and wago type connector suitable for 2 pole connection. the weight of the fan shall not be more than 3 kg.

CTN :41289002 Due date: 28 Aug, 202528 Aug, 2025 NA
Tender For supply of supply of consumables /implants /devices/accessories, on consignment basis for ctvs - ventilator, invasive pressure monitoring, iv drip sets, anticoagulation monitoring and airway consumables, bain circuit adultbased on mapleson "d" system, provided with a corrugated tube, expiratory valve and antistatic bag.should have co-axial modification of the basic "t"-piece system, developed to facilitate scavenging of waste gases.the process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube.lightweight anesthesia delivery system., bain circuit pediatricbased on mapleson "d" system, provided with a corrugated tube, expiratory valve and antistatic bag.should have co-axial modification of the basic "t"-piece system, developed to facilitate scavenging of waste gases.the process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube.lightweight anesthesia delivery system., corrugated tube connectorshould allow connection between all breathing circuits and the et tube connector.thecorrugatedtubeshouldbeexpandable.shouldallowmovementofbreathingcircuitatpatientend.should be made of medical grade pvc.should be compatible with ett and tracheostomy tube., micro aggregate blood filter for red cell transfusionfilter media should be 40 micron rated polyester screen media with uniform pore sizeshould have total filter surface area of 170 sq.cmshould have average capacity of filtering 10 units of blood., packed red cell & whole blood leucocyte reduction filters.bedside filtration of one & two unit of packed red blood cells or whole bloodshould have universal spike with microbiological recovery ventshould be with attached straight administration set/automatic self leveling drip chamberperformance should consistently average less than 2x105 residual leukocytes per unitred cell recovery should average greater than 90%.filter housing hold up volume should be 25ml for one unit filter and 35ml for two unit filterit should be single use, forced warming blanketshould be disposable and two layered; should consist of non woven propylene fabric for body warming. should be usable with forced air warming units. material should be latex free and should meet flammability standard 16 cpr 1610 for safety. the manufacturer must have all the below listed types of blankets and should quote the prices separately for separate blankets full body adult underbody adult with arm and head openings pediatric full body pediatric underbody blanket. should be compatible withcommon machines. should be ce certified, cuff inflator and pressure gauge itisusedtoinflate& preciselymonitorthecuffpressureofet tube, tracheostomy tube and lma cuff. reducetheriskofpressurenecrosisandmucosal ischemia theriskofaspirationcanbeavoidedeliminatestheuseofsyringestoinflate&deflatethecuffs. should have release valve to adjust the pressure. gaugecalibratedincmh2owiththedetachablelongconnecting tube. shouldhaveinflationbulbfortheinflationofthecuffshouldhavethehookatthebackoffitsintostandardrail.should have widely spaced scale markings with colour coded pressure ranges.ergonomiconehadoperation, intubation pillow reusable intubation pillow for head elevated laryngoscopy position (help) for airway management of obese &l arge framed patients. shouldbemadeupofdensefoam. shouldbesuppliedwithheadcradle shouldbevinylcovered shouldbecemarked, negative insipratory force meter should be disposable, compact, light weight & amp;single patient use negative inspiratory force meter to check the negative inspiratory force of the ventilated patients with the facility of memory indicator point ertore cord reset highest force achieved by the patient individually packed ready for use. shouldbe ,ce marked, capnography co2 sampling mask shouldhavetheprovisionforbreathtobreathmonitoringforboth nose & mouth should have the facility to deliver oxygen; allow sampling of exhaled carbon dio

CTN :41281239 Due date: 21 Aug, 202521 Aug, 2025 NA
Tender For supply of compact, lightweight, multistage borewell type submersible pumpset with motor as per attached specs
 Loading, Please wait...

Connect us via What's Up