Tender For supply of relay testing jig with the following hardware requirement are required to be adhered to for the relay test equipment - test equipment for qn1 & qna1 series of relays covering 12f4b, 8f8b, 8f4b, 6f6b, 4f4b relay types. microcontroller-based relay test equipment with an inb uilt database that would store, prepare & print test results. the requirement also specifies for a hdm i port and a usb communication port. 1) the test equipment should be microcontroller based 2) sho uld include low noise and high accuracy/high resolution a/d converter 3) the equipment should be pr ovided with a 7" touch screen display for frontend - graphic user interface (gui) and an additional liq uid crystal display (lcd - 16 x 2) - to displays the relay type being tested and the progress of relay t esting cycle 4) should be equipped with a hdmi port for connecting to an external display 5) a unive rsal serial bus (usb) based communication interface to export test data to ibm pc compatibles. 6) a wireless keyboard and mouse 7) a plug board to securely place the relay to be tested 8) powder coa ted mild steel cabinet inspection : tpi (third party inspection) [ warranty period: 30 months aft er the date of delivery ]
Tender For supply of infrared thermal imaging system (thermovision camera) having touch screen, temperature range from 0 to 500 degree celsius or higher, with rechargeble battery bank, scanned image can be downl oaded from usb port. cameras software should be license free so that it can be installed at multiple pc. ma terial shall conforming rdso specification no. ti/spe/ohe/tips/1031. [ warranty period: 30 months after the date of delivery ]
Tender For providing of annual maintenance service - desktops, laptops and peripherals - desktop pc; hp/dell/acer/lenovo,annual maintenance service - desktops, laptops and peripherals - laptop; dell,annual maintenance service - desktops, laptops and peripherals - all in one printer/laser jet printer/ink tank printer; brother/hp/epson/canon,annual maintenance contract for networking devices (version 2) - 24 port giga managabe switch; cisco sg 350,annual maintenance contract for networking devices (version 2) - maintenance of existing working lan nodes; cisco,annual maintenance contract for networking devices (version 2) - routers; router and access points,annual maintenance service - desktops, laptops and peripherals - ups( offline 1 kva); microtek/apc,annual maintenance service - desktops, laptops and peripherals - coast guard specific life certificate kisok(19 touch screen with printer); intel 19,annual maintenance service - desktops, laptops and peripherals - 24x7 technical manpower for handling desktop pc /printer/ ups/ lan
Tender For supply of indoor led wall 9 x 6.6 ft with 8 input quad mode , display wall controller with 15.6 inch table top touch panel and touch panel stand , display wall processor , output switcher , l2 switch , 75 inch side display , audio amplifier , ceiling speaker , monitor speaker , integrated tile mic , wired handle mic , ups 15 kva online , utp lan cable , rj 45 connector , hdmi cables , creation of facade for indoor led wall led screen side display brackets for all items , vertical hand screen dispenser system size 9x7 ft including installation , visualizer , multimedia projector , desktop computer
Tender For supply, installation commissioning of metal kiosk surface mounted - ms/ss with thin client ( minimum 2 ghz dual core x86 processor or better, 4 gb ddr3 memory ram expandable to 16 gb memory or higher, flash rom: thin client-minimum 32gb sata/msata flash expandable to 256 gb flash or higher memory), touch screen monitor (led 17''), key board & mouse (del/hp/similar) & ups stand alone type(1 kva, li with smf battery, brand-apc/bpe/similar) along with ba (tayaltech/similar), biometric device (secu gen/ or similar) and web camera (logitech c/270/equivalent) as per cris/ndls specification letter no. 200 7/cris/ndls-hq/cms/project//rollout-ii/0030/pt-ii dated 26.07.2024(attached). [ warranty period: 36 mo nths after the date of delivery ]
Tender For bid to ras corrigendum : supply of local purchase of ars items against nac e e - soap liquid toilet , scrubber with handle , safety gloves cloth , room freshener , refill for automatic air , rat sticking gel , pvc flexible water hose 1 inch , polish metal brass , photocopier paper a3 , photocopier paper 210mm x 325 mm f s , teflon tape , tape transparent 1inch , tape transparent 2inch , tape insulation 25mm , synthetic mat red , synthetic mat green , super mop refills , steel cleaning liquid , spray hand liquid insecticide , spin mop set , wonder tape 2inch , wiper long handle , varnish touch wood , urinal screen mats , torch cell 1 5v medium , toilet paper roll , telephone cable 4 core
Tender For purchase of sports physiotherpy lab equipments - focused shockwave therapy the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high laser therapy should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser power output of 15 watts should have wavelengths of 810 nm & 980 nm should have an aiming beam of 650nm, should have 2 operating modes: continuous wave or pulsed applicate and piece should have embedded finger switch and light, should have a technology to customize patient treatment based on conditions, body area, body type, skin type, chronicity and absorption characteristics applicator should have a fused silica composition massage ball at the point of contact of applicator and skin. pulse frequency: 2, 10, 20, 100, 200, 500, 1000, 2500, 5000 & 10000hz pulse duration: 50% duty cycle at any given pulse frequency setting, should have a 10 hd display touch screen with password protection to reach the home screen should be supplied with 2nos. of laser protection glasses power: 100-240v, 50-60 hz the unit should be supplied with 5 different types and sizes of treatment heads (large cone, large massage ball, flat window, small massage ball, and small cone. the unit should have inbuilt battery. electrical safety class: class i, type b weight should not exceed 4 kilograms (main unit; without applicators & accessories. must have class iii also., combination therapy machine with vaccum should have 3 independent electrotherapy channels, one ultrasound channel should provide multiple clinical waveforms including interferential (2 and 4 poles and isoplanarvector), tens (asymmetric biphasic &symmetric biphasic), han, russian, vms, surged(rectangular &triangular), hvpc, microcurrent, galvanic (continuous, interrupted and low level),rabert & dia dynamic cpid/cpiso should have independent parameter adjustments for each channel including intensity, frequency, duty cycle, vector scan, channel mode, phase duration, ramp, cycle time and treatment time based on waveform should have maximum output intensity up to 140ma should have constant current and constant voltage modes should have 2 colour coded lead wires for easy picking of selected channels should have suggested electrode placement guidelines ultrasound should offer 1 and 3 mhz frequencies should have the ultrasound bnr of 5:1 or lesser should be supplied with one 5cm applicator head should have pulsed & continuous frequency modes (10%, 20%, 50% & 100%) should have variable duty cycles of 16 hz, 48 hz &1 bb 00 hz should have facility to indicate applicator uncoupling should be able to use electrotherapy and ultrasound independently and also in synchronizedcombination of electrotherapy and ultrasound, where ultrasound head functioning as bothultrasound head and electrode should have minimum 7 high resolut
Tender For purchase of recovery and rejuvenation lab. - infrared sauna tower irradiance: 55-110 mw/cm2, providing therapeutic benefits rated power: 100-240v ac, 2 amp, 50-60hz, suitable for standard electrical outlets wattage: 350w, combining red light and near-infrared therapy wavelength: 650nm (red light) and 850nm (near-infrared), promoting healing and relaxation led arrays: 70 red light leds (650nm) and 70 near-infrared leds (850nm), ensuring optimal coverage variable optics: 7 60-degree optics for maximum impact and quicker results. emf emissions: no detectable emf emissions at 10-15cm, prioritizing user safety. infrared sauna units with below mentioned features to be preferred- heaters: full spectrum heaters (400w each) or carbon fiber heaters (up to 2160w total power) temperature control: digital temperature and time control for customizable sessions materials: canadian hemlock wood or western red cedar, known for durability and hypoallergenic properties additional features: bluetooth connectivity, chromotherapy lights, and built-in stereo speakers for an enhanced experience. energy efficiency: reduced electricity consumption for cost-effective use temperature range: operating temperatures between 115 f and 140 f for comfortable sessions safety features: person-specific designs and low emf emissions for safe use, cryotherapy chamberwhole body cryo therapy chamber that runs completely on electricity without need of liquidnitrogen low temperatures within the range: -130 to -140 degree celsius. multiple treatment options electric mechanical lift system ensures user s head is outside the chamber to prevent exposure to cryogenic temperatures. real-time skin temperature monitoring using ir tech sensors ensuring safe and controlledcooling. smart software that manages the treatment processes throughout each session. simple quick plug-and-play set up without requiring specialized ventilation. large uhd touchscreen for easy operation and control. at least 3 media monitors for displaying media content. hifi speakers for audio entertainment and ambient audio. work on normal indian 220v at 16a or less, whole-body pneumatic lymphatic drainage machine:key features- multi-chamber design: multiple chambers that inflate and deflate in sequence to mimic manual lymphatic drainage- adjustable pressure: adjustable pressure settings to accommodate different patient needs and comfort levels- programmable treatment: programmable treatment protocols for customized therapy sessions- user-friendly interface: intuitive interface for easy operation and programming- input voltage: ac110v/220v- power consumption: less than 400w- screen: 8-inch wide color touch screen- air pressure: 20-360 mmhg (max pressure 37.5kpa)- cooling device output temperature: 5 to -16 c- output vacuum pressure: 0-110kpa- default time: 0-60 minutes- fuse size: f3al250v- ambient temperature: 5 c to 42 c- number of air bags: 24 bags or 16 pairs atleast - treatment modes: 4 modes atleast - intensity levels: 3 levels- package size: 62x42x31cm approx - gross weight: 15 kg approxsafety features- automatic pressure adjustment: automatic pressure adjustment to prevent excessive pressure and ensure patient comfort- emergency stop: emergency stop feature to quickly deflate chambers in case of discomfort or distress- patient monitoring: optional patient monitoring capabilities to track vital signs and treatment responseadditional features- multiple treatment modes: multiple treatment modes for different conditions, such as lymphedema, edema, and post-surgical swelling- data logging: optional data logging capabilities to track treatment parameters and patient progress- portability: optional portable design for increased flexibility and convenience.certifications: ce or fda clearance, percussion massager (gun massager)key features- percussive action: a percussive action that provides rapid and repetitive strokes to muscles and tissues- adjustable speed: adjustable speed settings to customize the mass
Tender For purchase of biochemistry lab equipments - fully automatic biochemistry analyzerthroughput: 200 photometric tests/hour & 400 tests/hour with ise (optional)reagent positions: 50 cooled reagent positionssample type: whole blood, serum, plasma, urine, csf otherreading volume: 180 lsample volume: 2-70 l (adjustable in 0.1 l)reagent volume: 10-300 l (adjustable in 1 l)light source: halogen lampon board laundry: 6 stage cleaning, 2 stage drying with cuvette validation stepcalibration type: linear, non-linear, multipointprogrammable parameters: default system pack parameters + upto 10 user defined parametersdimensions and weight: ergonomic design and light weight., fully automatic hematology analyzerthroughput-up to 80 samples per hourdimensions and weight ergonomic design and light weighttest mode-cbc, cbc+diffdata storage capacity-up to 100 000 resultscommunication-lan port supports hl7 protocolpower requirement-a.c. 100-240 v, less than or equal to 300 va, 50/60 hzoperating temperature-15 to 30 degree celsiusoperating humidity-30-85%air pressure70-106 kpa, fully automatic immunoassay analyser random assay (hormone analyser)instrument name: immunoassay analyserusage/application-clinicalplate format-random assaydetection method-luminescenceparameters-blood alcohol contentautomation-fully automaticuser input-touchassays-diabetes, thyroid, cardiac, vit d, fully automatic electrolyte analyser-analysis time: 60 second per sample parameters- na , k , cl or ca2+no. of parameters 3 simultaneously90 luser inputs 5 colored touch screen displayelectrode type- sturdy electrode (facility to refill the solution)connectivity 2 usb port, rs232, lisdata storage- 10,000 patient results & 10,000 qc results for 3 levelssample identification- alphanumeric sample idqc management- tri-level quality control, l j plots of last 30 dayscalibration- 2 point calibration on every 4 hours1 point with every samplepower - 100 240 v, 50/60 hz (self adjusting)printer - inbuilt thermal printerroom temperature -15 30 c / 60 90 fhumidity- 85%dimensions and weight - ergonomic design and light weight, centrifuge machine along with 500 prp test tubes (double spin)parameter- neya-16 max speed (rpm)- 15000max rcf (g)- 21000max capacity (ml)- 4 x 175acceleration profiles- 10deceleration profiles- 10display-- multi-color lcdno of programmes- 10 (protected)timer- 30 sec to 99 min & continuous modeergonomic design and light weightsupply - 220v, 50 hz, 1 phasecan be used for extracting prp, autoclavekey features- high-pressure vessel: a high-pressure vessel designed to withstand high temperatures and pressures- temperature control: precise temperature control to ensure effective sterilization- timer and controls: easy-to-use timer and controls for convenient operation- safety features: multiple safety features, such as automatic shut-off and overheat protection, to prevent accidents and ensure safe operationconstruction and materials- stainless steel: a durable stainless steel construction to withstand high temperatures and pressures- insulation: high-quality insulation to ensure efficient heat retention and energy savings- door and seals: a secure door and seal system to prevent steam escape and ensure effective sterilizationperformance specifications- temperature range: 121 c to 134 c.- pressure range: upto 30 psi- cycle time: 15-60 minutes- sterilization capacity in liters or cubic feetsafety standards- compliance with regulations: compliance with relevant regulations, such as asme, fda, and iso standards- automatic safety devices: automatic safety devices, such as overheat protection and low-water cut off, to prevent accidents and ensure safe operation- interlocks: interlocks to prevent door opening during operation and ensure user safetyadditional features- data logging: optional data logging capabilities to track temperature, pressure, and cycle data- printed records: optional printed records of cycle data for documentation and quality control- validation and te