Web Analytics Made Easy - StatCounter

Computer Router Tenders

Get complete information related to latest Computer Router Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Computer Router Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Computer Router Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42901834 Due date: 09 Dec, 202509 Dec, 2025 NA
Tender For purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp frequency: 0.00001 t

State Government

CTN :42971848 Due date: 18 Dec, 202518 Dec, 2025 91.81 Lacs
Tender For a) scope of work covers supply, installation and commissioning of total 12 nos.of 3d radar level transmitters for the coal level measurement in raw coal bunkers of rtps-unit-5&6 with required pcs, electronic modules, splitters, modems, junction boxes, mounting kit, enclosures, interconnecting cables, software and all other accessories required to make the system complete and fully functional, shall be provided for continuous level measurement and monitoring of level of each coal bunker and also to ensure satisfactory performance of the system commissioned at rtps site which shall be on the basis of single point responsibility, completely covering the activities and services in respect of all the equipment works specified and covered under the specifications. the work involves i) installation and commissioning of 12 nos. 3d radar level type level transmitters with suitable mounting accessories, display indicators, isolators, annunciator, smps, terminals, panel internal wiring, led bulbs, door switch etc. at the bunker level ii)commissioning of rs 485 communication /other cables from bunker level transmitters to the desktop pc at u-5&6 control rooms.iii)commissioning of desktop pcs for 3d multi vision for monitoring of all the 12 bunkers level at u-5&6 control room respectively and also both units bunker levels at pc being installed at chp control room. iv)loading of all the required licenced software to the desktop pc for 3d radar level transmitter and cable routing, glanding, mounting of cable tray, termination and ferruling is in the contractors scope.cable trays will be provided by m/s.kpcl.b)all fabrication works required for installation and commissioning of instruments with jbs,protective cover/canopies and allied works are in contractor/agency scope itself.c) all civil works like drilling/cutting rcc floors,grouting,refilling floors,conduiting under ground cables cable tray mounting, masonary works are in contractor/agency scope itself.d)storage of materials while executing works is single point responsibility of contractor/agency scope itself. e)software details-1. the page containing all bunker level data shall be in full page which must be visible from at least a distance of 6-8mtr .(font size should be more) and shall have a historical trend storage for minimum 45days & real time trend with not less than15min sampling time. f) at chp control room, the existing kpcl pc shall be enabled with bunker level software & shall be communicated through existing lan and as a redundancy the seperate optical fiber cable communication with media convertor has to be provided.the lan cables has to be protected with cable conduit g)materials supply shall be completed in all respect within the stipulated period as per the contract. materials shall be delivered to rtps site through ee(stores)o&m. unloading of materials at rtps site location and shifting of the same to work location is under the contractor/agency scope only. h)handling, shifting, unpacking and erection and commissioning of the entire system shall be under the scope of bidder itself. i)all required consumables, hardware and licenced software, accessories and any other materials which are not included in the scope and required for successful installation and commissioning of the 3d radar level transmitters for the coal level measurement in raw coal bunkers of rtps-unit-5&6 are under the contractor/agency itself. j)all the materials required for the installation and commissioning of 3d radar level transmitters for the coal level measurement in raw coal bunkers of rtps-unit- 5&6 shall be made as detailed under the technical specifications. k)interfacing of all the bunker level transmitters outputs to the desktop pcs at u-5&6 control rooms through rs - 485 communication protocol.(the required 1 pair x 1 sq.mm shielded armoured cables as per requirements shall be supplied approx-500 meters or if more). for more details of scope of work refe

State Government

CTN :42951079 Due date: 11 Dec, 202511 Dec, 2025 15.77 Lacs
Tender For tender for procurement of lab equipment for analog electronics circuit lab and digital electronics lab at dept. of electronics and communication engineering, vtu constituent college, chintamani - advanced fpga kit fpga xilinx spatran 6xc6slx9., ic 7400,7486,7408,7495,7404,7490,74192,7432 each 10, patch cords 1, digital ic trainer kit, op-amp 741, op-amp power supply (-5v to +5v), capacitor 0.1,0.01,100,0.22,0.47,1.3nf,47,47pf each 20 nos, transistor sl100, sample and hold ic -lf398, audio transformer ratio, signal generator 1, regulated power supply 0-30v, audio signal generator 1mhz, dual trace oscilloscope 20mhz 1, function generator 1mhz 1, op omp 741, single strand connecting wires 1, bread board 1, by127 diodes, in4001 diodes, ic555, digital multimeter 1, transistor sl100, bf194 each 20 nos, resistors 1k,10k,3.3k,470,22k,33k,3.3k each 10 nos, capacitors 1) 0.01uf, 2) 0.1uf, 3) 1uf each 30 nos, ic 7490, ic 565, cro probes 1, patch cords, data bit generator, data trainer kit, data encoding kit, cro digital 20mhz, pcm modulation and demodulation st2103 trainer

Central Government/Public Sector

CTN :42763899 Due date: 09 Dec, 202509 Dec, 2025 NA
Tender For supply and installation of 02 channel voice data recording and processingunit (vdrpu) as per rdso /spn / tc / 38 - 2002 ver 2 or latest.supply and installation of vhf receiver to record communication with in the radio coverage area of station vhf equipment. note: vhf based secured communication equipment has in-built vhf radio which is configured on dg (driver guard) frequency to record communication. if railways also wants to record communication on shy frequency simultaneously, then this is required per location.supply of server hardware and software for centralized monitoring of voice communication with voice logging for entire stations in nagpur division through vhf based secured communication equipment as per no rdso / spn / tc / 38 - 2002 ver 2 or latest amendments or latest. the technical specification is as follows: - (i). processor - intel core tm i7-6700t, memory: 16gb, hard drive: 1 tb ssd, graphics card: nvidia geforce gt 730 (4 gb ddr3 dedicated), networking 802 m, 11 b/g/n (1x1) and bluetooth 4.0 m. 2 combo, sound card: dts studio sound?, keyboard, and mouse: hp usb wired keyboard with volume control, power supply: 180w ac power adapter, audio: dts sound?, memory slots: 2 dimm , external i/o ports: 2 usb 3.0; 4 usb 2.0 dimm, windows 11 operating system, led monitor: 24 (23.08
 Loading, Please wait...

Connect us via What's Up