Get complete information related to latest Concerting Coil Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Concerting Coil Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Concerting Coil Tenders.
Tender For supply of routine and breakdown maintenance works of aph -replacement of heating element.when the elements strips are to be dismantled and cleaned with wire brush. , servicing and minor repairing of flue gas primary air and secondary air inlet, outlet and inter connecting dampers of aph. flue gas dampers. , servicing and minor repairing of flue gas primary air and secondary air inlet, outlet and inter connecting dampers of aph.primary air damper , servicing and minor repairing of flue gas primary air and secondary air inlet, outlet and inter connecting dampers of aph.secondary air damper , servicing of flue gas primary air and secondary air inlet, outlet and inter connecting dampers of aph flue gas dampers. , servicing of flue gas primary air and secondary air inlet, outlet and inter connecting dampers of aph primary air damper , servicing of flue gas primary air and secondary air inlet, outlet and inter connecting dampers of aph secondary air damper , repairing of flue gas, sa, pa inlet and outlet duct manholes cover. , repairing flue gas dampers flaps. , repairing of pa damper flaps. , repairing of sa damper flaps. , repairing of semi circular baffle. , repairing of distance pieces in fg duct. , repairing expansion joints before and after air pre heater. , cleaning of cooling water line of lubricating oil pumps of aph by cutting and welding. , repairing of hangers of sector plate. , decoupling and re-coupling of electrical motor for replacement of electric plate and fluid coupling etc. , fabrication of bracket 1 set equal to one no. in board and one no. in outboard bracket. , replacement of brackets. , leveling of rotor. , water washing and cleaning of flue gas duct sa duct. , providing sealing cover on expansion joints. , repairing of t-bars. , replacement and repairing of fg duct by cutting and welding. , adjustment of axial seal plate. , complete replacement of the static seal of aph , re- visioning or repairing of air seal housing of guide bearing of aph. , alignment of electric motor and air motor with reduction gear box of air pre-heater. , replacement of gear box of air pre heater. , cleaning of water washing nozzle, elbow and socket. , repairing of oil or water valve lube oil system of size 25mm. to 40mm. , replacement of oil or water valve lube oil system of size 25mm. to 40mm. , servicing or overhauling of over running clutch system of aph. , checking of gear box of aph. , cleaning or servicing of support bearing and their housing. , repairing and reconditioning of centre section surface beneath guide bearing and casting the refractory. , leveling of sector plates of hot end or cold end. , replacement or reversal of he ie ce basket aph. , hot washing of air pre heater. , cleaning of air pre heater through nozzle. , round the clock checking and routine maintenance of air pre heaters of unit no 12 and 13 btps, obra , round the clock checking and routine maintenance of air pre heaters of unit no 9,10,11 btps, obra
Tender For corrigendum : supply of sch viii (supply of needle & syringes) - sch viii (supply of needle & syringes), disposable needle sterile length 1/2" guage 25, suture needle, half circle triangular nos. 2 to 20 (cutting), insulated needle for use with peripheral nerve stimulator 22g x 2" x 50 mm., insulated needle for use with peripheral nerve stimulator 22g x 35 mm., insulated needle for use with peripheral nerve stimulator 24g x 1"x 25 mm., echogent needles for usg guided peripheral nerve blocks 20g / 21g x 100 mm., echogent needles for usg guided peripheral nerve blocks 22g x 50 mm., epidural needles 16 & 18 guage 7.5cm to 11cm (disposable), epidural needles (long length) 18g (more than 100 mm. length), sterile disposable lancet size 28-32 (plastic lancet needle type), sterile disposable hypodermic plastic syringe 20cc, cn. with leur lock, hypodermic syringes,disposable sterile, sterile pack,with/without leur lock, hub 1ml syringe with marking at 0.1 ml, asepto syringe 100 ml of heavy plastic barrel and rubber bulb with marking., bag arm rubber with cover for b.p. apparatus, adult size velcro.rubber bag size 13 x 23 cms., keratome, size 2.8 mm, type-regular(ophthalmic), angle-45 degrees, bevel type- bevel up (pointed)blade-stainless steel/carbon steel,handle- polycarbonate, use- disposable single use, mvr, gauge 23g type-regular(ophthalmic), blade-stainless steel handle- polycarbonate, use- single disposable use, triple lumen catheter 7.5fr with 14g distal lumen, length-15cm. kit contain 1 teflon-coated j nitinol guidewire particularly kink-resistant with guide-advancer. 1 dilator, 10cm long, 3 injection caps, 3 clamps,1 supplementary fixation wing,1 scalpel, 1 syringe 5 ml, 1 adaptor for pressure transducer, 1 puncture needle 18g, 70mm long with a pre-connected valve to aviod air embolism and blood loss, 18g short iv cannula, double lumen subclavian/ jugular catheter kit (adult) ptfe (teflon) cannula curved od 2.7/d 11.5fr-12fr/chx5.3in. (3.8 mm x 13.5 cm) 6 side holes silicon tube s clamping extension, clamp luer lock "y" connector with protective caps size 12.5, 15 with guide wire introducer needle, dialator , 3fr double lumen cvc catheter with 60mm double-lumen polyurethane central venous catheter inserted by seldinger technique, radio opaque material for catheter, the user should be able to choose from 2 type of introducer, i.e.needle 23g or i.v. cannula 22g, latex free, the central venous catheter set should contain: 1 double-lumen polyurethane 3fr catheter, 1 short i.v. cannula 22g, 1 introducer needle 23g, 1 kink resistant guidewire with soft flexible tip, dilator with cylindrical /pencil point tip, 1 secondary fixation wing, 2 injection caps, 1 scalpel, 1.5 ml syringe, peripherally placed radiopaque central single lumen catheter. guage 14/16 (100%) (needles size/catheter size) length - 55cm - 70cm, peripherally placed radiopaque central single lumen catheter. guage 18/20 (100%) (needles size/catheter size) length 30cm - 45cm, fully radiopaque pur catheter 16g for femoral artery centimeter marking from 5-15cm, winged hub for skin fixation, supple distal tip. kit should contain 1 pur catheter with xro lines,1 puncture needle, 1 j guidewire with wishbone-type guidewire advancer, 1 dilator, radial/femoral arterial pe catheter with antikinking collar & fixation wings,straight guide wire, introducer needle.catherter size g- 18, length 10cm, radial/femoral arterial pe catheter 20g, 8cm puncture needle is fitted with a visualization chamber allowing to confirm that the vessel punctured is an artery (pulsatile movement of the blood). the needle is also fitted with a silicone bloodless system valve to avoid loss of blood during vessel puncture and a funnel hub to facilitate the insertion of the guidewire, peripherally inserted central catheter with guide wire with peelable cannula, made of polyurethane, non-toxic, with radio opaque line throughout the catheter with marking every cm with leur connector at proximal en
Tender For supply of 2 point 4 per 1 point 7 f pre shaped tip low profile shaft neuromicrocatheter with 0 point 0165 inch inner and 0 point 014 guide wire compatible like excelsior sl 10 , stent neuro self expandable braided for intracranial aneurysm neck remodeling with delivery wire and delivery micro catheter 3 point 5 x 18 mm such as lvis from microventionpoint , stentretriever neuro for mechanical thrombectomy non detachable self expandable nitinol based open , catheter micro dmso compatible with 1 point 5 f distal od 2 point 7f proximal od 165 cm length such as marathon from medtronic , stent carotid self expandable dual layered open cell with outer ptfe mesh such as c guard from inspire md , microcatheter braided two to tip marker steam shapeable tip distal tip of at least 2 point 1 f suitable for neurointervention having inner diameter of at least 0 point 027 inch , 3 d self detachable neuro embolisationloils 5 to 8mm 5 to 20 cm length for framing of neptured aneurysm like target 360 stryker , soft tip intracranial 6f guiding catheter for distal smooth navigation like neuron penumbra , polyvinyl alcohol particles 150 to 250 microns , polyvinyl alcohol particles 250 to 350 microns , polyvinyl alcohol particles 350 to 500 microns , polyvinyl alcohol particles 500 to 750 microns , syringe luer lock polycarbonate construction for use with sclerosants etc 10 ml , percutaneous catheter introducer sheath set 11 cm to assorted sizes , histoacryl glue n butyl cyanoacrylate , hydrophilic coated guide wires suitable for negotiating tortuous vascular anatomy with j curve tip of 0 point 035 diameter and 150 cms length , guidewire amplatz ultra stiff 0 point 035 inch diameter 260 cm or more length available with 1cm coma 3cm and 6 cm floppy tip segment , cobra 1 c1 visceral braided torque control catheter 5 point 0 french 65 cms long permitting 0 point 035 inch guide wirepoint , kampe access catheter 5 f 65 cm length , flow diversion embolisation device for intracranial aneurysm like silk vista per surpass per pipeline per derivo , microguidewire nitinol constrction hydrophilic coating angled tip 0 point 014 inch diameter at least 180 cm length , microcatheter l 110 per 130 cm od distal 2 point 4 per 2 point 7f for peripoheral intervention glide m coating preloaded with 0 point 021 guide wire like progreat , haemostatic sponge gelatin 80 mm long 50mm broad 10 mm thick , semiautomatic core biopsy gun set with 02 throw lengths of 10mm and 20 mm in a single //bid details2 / 26
Tender For supply of rubber insulated mat 1mx2mx2. 5 mm 11kv , hose rubber wire braided 25mm , hose pvc 4 inch flexible heavy duty , retro reflective tape 50m by50mm , retro reflective mat , heliflex hose 2. 5 inch , 3 by 4 inch nylon hose , wooden guide rope block 7 by 4 by 3. 5 , chain link fencing 1. 5 m by 5m , adhesive tape flourescent 2inx50 mtr