Tender For tender for supply of operation and comprehensive maintenance of ems at kadma te build jsr d d - as per item no-1 of sh-i sor in sec-3 part c of atc , replacement 100amps 4 pole isolator , replacement 63amps 4 pole mcb , replacement 32amps 3 pole mcb , replacement 40-63amps dp mcb , replacement 6-32a spmcb , replacement 100 amps 415v hrc fuse links- din type , replacement 125 amps 415v hrc fuse links- din type , replacement 63 amps 415v porcelain fuse unit , supplying and drawing 3x1.5sqmm wireing , supplying and drawing 2x1.5sqmm , supplying and drawing 3x4.0sqmm , sf pvc junction box along with 150 amp 4 way connectors , suppllying xlpe 1.1 kv al 4x10 sqmm cable , suppllying xlpe 1.1 kv al 2x6 sqmm cable , laying of xlpe cable in ground , laying of xlpe cable on wall surface , laying of cable existing rcc/ hume/ metal pipe , sh 40 mm dia g.i pipe medium class ias per nit. , sm end term with brass gland and alum lugs 4 x 10 sq. mm , sm end term with brass gland and alumi lugs 2 x 6 sq. mm , repl. 63 amps 415 volts tpn sdfu with hrc fuses , repl. 125 amps 415 volts tpn sdfu with din type hrc fuses , repl. 250amps 415 volts tpn sdfu with din type hrc fuses , repl. 400a fp mccb , 36ka overload rel , repl 63 amps 415 volts tpn sdfu in sheet , s/f 36 /40-watt fluorescent tube rods , s/f starter for fl. fittings , s/f 9 /10-watt led lamp (b22) , s/f 12/15-watt led lamp (b22/e27) , s/f 20/22w ultra bright led retrofit tube light , s/f 24w led battype with very high eff 115 lm/w , replacement angle/batten holder , replacement 36/40 w fl tube light holder , replacement 36/40 w fl tube light starter , replacement ceiling rose , replacement 5/6amps 250 volts 3 pin plug top , 15/16amps 250 volts 3 pin plug top , replacement 6 /10 amps 1 way piano type switch , replacement 16 amps 1 way piano type switch , replacement 6 amps 3 pin type socket , replacement 16 amps 3 pin type socket , rewinding of 1200mm/1400mm ceiling fan etc. as required. , repl stepped type electronic fan regulator (switch type) , rep 2.25 mfd 440 volts capacitor for ceiling fan , bearings for ceiling fans etc. as required (make skf/ss) , rewinding 380mm 1500 rpm 230 v heavy duty exhaust fans , supply and replacement of 45 watt street light , supply and replacement of 27 watt street light , dehyd filt & testing of existing trasformer , supplying of new transformer oil , replacement gasket of transformer , replacement lt side stud bush , painting of transformer with good quality synthetic paint , s/f diesel filter with o ring (primary) 160kva d e/a set , s/f lub oil filter with o ring 160kva d e/a set , s/f diesel filter with o ring (secondary) 160kva d e/a set , s/f engine oil(mobil) 160kva d e/a set , sevicing by authorised dealer /oem for160kva dg set
Tender For supply of 4500nos of stay set complete - supply of silicagel blue, 0.6kva ups, stay set complete( quote price for single unit only), silicagel blue 10 to 12mm, pole pit for 9.0m and 9.14 m psc/rcc / all metal poles (each pit) 1.25 x 0.6 x 1.83 mtr, ordinary soil, semi rocky soil, heavy rocky soil where blasting/ cheseling required [specific approval should be obtained from concerned ee], stay pit, in ordinary soil [0.95 x 0.6 x 1.2m], semi rocky soil, stay pit in heavy rocky soil where blasting/ cheseling reqiured [specific approval should be obtained from concerned ee], erection of poles & stays (including refilling of excavated earth), erection of 7.5m / 8.0m poles [rcc / psc], erection of 9.00m / 9.14m rcc / psc/rail pole, tubular pole and all metal poles, stay set, erection stay set complete, stay erection without rod and pit, replacement of stay rod only. (including stay pit excavation & refilling & erection), replacement of guy shackle only in existing stay, erection of line materials, fixing of lt 1 ph "x" arm, fixing of lt/ht ti fitting, fixing of lt 3 ph "x" arm, fixing of 3[1/2] v ` x arm, fixing of 4[1/2] v ` x arm, fixing of 5 v x arm, fixing of tapping channel / guarding "x" arm, providing of line spacers in lt lines 1 phase, providing of line spacers in lt lines 3 phase, erection of ab switch with pt insulator & jumpering complete, erection of centre rotating switch ab switch complete, fixing of ht pin insulator / strain disc, 11 kv pin insulator with pin, 11 kv strain disc / polymer disc with hardware, 22 kv pin insulator with pin, 22 kv strain disc / polymer disc with hardware, 33 kv pin insulator with pin, 33 kv pin strain disc/polymer disc with hardware, fixing of lt pin insulator with pin, lt shakle with hardware, fixing of aluminium knob, paving stringing and sagging of conductor including binding of pin and proper tight [including transport of condutor from road side to work spot] per run, upto 7/2.59 mm acsr, 7/2.50 aaac including pvc cable upto 25 sqmm, acsr 7/3.35mm & 7/ 3.15 aaac including pvc cable above 25 sqmm, acsr 7/4.09 mm, above 7/4.09 mm acsr & dog conductor, earthing wiring and connection including transporting of earth pipe and excavation of pit], transformer structure earthing 10ft depth - 3 nos of pipe through tubes, dp earthing including all works [double side earthing], erection of 4th earth pipe including earthing, earthing of poles, earth pit masonary work 3 nos earth pits or using 3 nos concrete tub., replacement of detoriated earth pipe per location, concreting with mixture 1:3:6 [including all materials]., mass concreting for centre support for 2 feet including all materials, mass concreting for pole0.6x0.6x1.25m.with coping, sleeve concreting for pole 0.6 m x 0.6m x 0.3 m with coping, sleeve concreting for stay set 0.3 m & 0.75 long, erection of distribution transformer structure complete, excavation of structure pole pits 0.9 x 0.9 x 1.83 mtr, transporting of pole to pit location 2 nos., erection of poles 2 nos, excavation of stay pit 4 nos, erection of stay set (4 sets), mass concreting (cement:sand:jelly supplied by the contractor) 2 nos., erection of 22 kv ab switch, ttransformer structure earthing 10ft depth - 3 nos of pipe through earth tubes, erection of top channel, bed channel [2 nos channel] erection, cross with stud for bed channel erection, erection of belting angle / hg fuse angle, erection of hg fuse set, erection of ht las with jumpering and earthing, erection of lt las with jumbering and earthing, erection of jumpering [ht side], transformer wiring in lt side including jumpering bus bar etc., erection lt open type fuse unit arrangement single, erection lt open type fuse unit arrangement double, painting of stru. complete excluding dt [two coat of red oxide] all metal parts(excluding cost of paint)., painting of stru. complete excluding dt [one coat alu paint, excluding cost of paint), colour washing of 2 numbers structure pole [excluding c