Get complete information related to latest Condenser Coil Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Condenser Coil Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Condenser Coil Tenders.
Tender For supply of heat exchanger (for hydraulic circuit of ikt f/f machine) as per specificatios and drawings enclosed , heat exchanger (for coolant circuit of ikt f/f machine) as per enclosed specifications and drawing
Tender For supply of high ambient industrial ac d d - condensercoil part code i06122 , condenser fan impeller part code i05442 , condenser fan motor part code i04084 , filter drier part code i00162 , oil separator part code i00165 , liquid receiver part code i01721 , temprature controller part code i03692 , connection pipe liquid part code i04336 , connection pipe gas part code i04576 , evaporator coil 1 part code i05505 , evaporator coil 2 part code i05506 , evaporator fan part code i00082 , air filter part code i05527 , connection pipe liquid part code i05429 , connection pipe gas part code i05106 , evaporator coil part code i03707 , evaporator fan part code i00088 , air filter part code i03372 , connection pipe liquid part code i05567 , connection pipe gas part code i05568 , oil level switch part code i02503 ) /bid number : gem/2026/b/7425233 * /dated: 08-04-2026 & & / bid document 1 / 22
Tender For supply of air conditioners : - split ac servicing _1.5 ton _2 ton_ , tower ac _4 ton_ , window ac _1.5 ton _2 ton_ , copper pipe with sleeve , compressor 1.5 tr non inverter ac , compressor 2 tr non inverter ac , compressor 4 tr non inverter ac , compressor 1.5 tr inverter ac , compressor 2 tr inverter ac , compressor 4 tr inverter ac , refrigerant gas charging 1.5 tr ac , refrigerant gas charging 2 tr ac , refrigerant gas charging 4 tr ac , pcb repairing 1.5 and 2 tr non inverter , pcb repairing 4 tr non inverter ac , fan motor 1.5 tr and 2 tr , fan motor 4 tr , condensercoil 1.5 tr and 2 tr , condensercoil 4 tr , power cable 4c x 2.5 sqmm
Tender For corrigendum : auction sale of depot miscellaneous scrap - 98414501]scrap condemned released and un-serviceable ac electrical scrap such as rmpu unit with condensercoil, evaporator coil and ac control panel complete set on as is where condition available under the custody cdms 07 ward ap. loc: bin no.1103 beside weigh bridge ref ds8 no-062042-23-05301 dtd 26-12-2023 note. the successful bidder should produce at least once during the currency of the original pcb certificate on the basis of which the depot officer will certify the xerox copy and keep in record for further action. this should be done before making first delivery. the successful bidder should also submit the relevant documents as per the extant rules at the time of taking delivery for verification of originals. if the purchaser fails to comply with this, emd will be forfeited.
Tender For supply of condenser and evaporator coil assembly in set and each set must consist of 2 nos of condensercoil (lhs and rhs) and 2 nos of evaporator coil (lhs and rhs) suitable for amit make lhb variant rmpu as per rdso spec no. rdso/ac/0061-2005(rev-1) or latest. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of condenser & evaporator coil assembly in set and each set must consist of 2 nos of condensercoil (lhs & rhs) and 2 nos of evaporator coil (lhs & rhs) suitable for stesalit make rmpu as per as per rdso spec no rdso/ac/0061-2005 (rev-1) [ warranty period: 30 months after the date of delivery ]
Tender For bid to ras supply of supply and fixing of expansion valve required for ac plant of capacity 5.5 tr , supply and fixing of v belt size a-28, a-32 suitable for 11 by 5.5 tr package unit ac , supply and fixing of micro filter for ac plant of capacity 5.5 by 11 tr , supply and fixing of outdoor fan motor for package ac plant of capacity 5.5 tr , supply and fixing of repair fan blade of outdoor unit of ac plant of capacity 5.5 tr , supply and fixing of connector for 30 to 40 amps, 440 volts , supply and fixing of contactor suitable for ac plant of capacity 16.5 by 11 tr , supply and fixing of auto change over switch for package type ac plant 11 tr , supply and charging r-22 gas to maintain required cooling effect as and when required in the package type ac , supply and charging r-407 gas to maintain required cooling effect as and when required in the package type ac , supply and charging nitrogen gas for finding out leakage as and when required as specified and directed by engr in charge , supply and fixing of microprocessor by printed circuit board with ct coil suitable for 11 tr package type ac plant , supply and fixing replacement of capacitor 10 mfd , supply and fixing of temperature display controller unit for 16.5 by 11 tr , cleaning of evaporator coils of ac plant of capacity 5.5 tr with dilute hcl by force feed method to remove the dust particles formed on coil and fins , servicing incl cleaning of condenser cooling coil, refrigerant coils fins with mild detergent and descaling of condensercoil for package type 5.5 tr ac , servicing incl cleaning of condenser cooling coil, refrigerant coils fins with mild detergent and descaling of condensercoil for package type 11 tr ac , disconnecting, dismantling and taking out existing burnt out compressor of package type ac 5.5 tr capacity and supply and fixing sealed unit compressor of existing capacity, single phase 230v ac , disconnecting, dismantling and taking out existing burnt out compressor of package type ac 11 tr capacity and supply and fixing sealed unit compressor of existing capacity, single phase 230v ac
Tender For bid to ras corrigendum : supply of bi facial solar panel 550 watt , topcon solar panel 610 watt , cut section of gate valve,globe valve,ball valve,diapharm valve,needle valve,check valve,safety valve,butterfly valve,pnematic control valve 4 inch diameter , cut section of centrifugal pump,gear pump,multistage c f pump,reciprocating pump,screw pump , cut section of shell and tube heat exchanger acrylic material , cut section of reactor with accessories motor,agitatot,support leg,nozzle,manhole,baffels,thermo well,bottom valve , vrf or vrv unit with two indoor unit 2 point 5 tr each and 5 tr capacity out door unit complete with air cooled condenser,accessories and controls,harmetic shield type compresor,r410 a single phase , evacuating and charging station as above but fitted with weighing scale 0 point 25 hp,230v,50 hz with gauge manifold , gauge manifold with gauges different size of hoses for r134a,r22,r32 and r 410 , wash bag cover jacket for ac service indore 1 point 5 ton,2 point 5 ton capacity , safety belt, industrial type full body protection double rope double hook,100 kg human weight , embroidery machine , brake test arrangement with two spring balance 0 to 25 kg rating , automatic motor coil winding machine with step arbor , three phase variable auto transformer ac varic 3 phase , 0 to 440v, 25a, 50 hz , synchronous motor, with accessories , vfd ac drive ac motor drive with vvvf control 3 phase , single phase transformer, core type, air cooled,1 kva,240 or 415 v,50hz , stepper motor with digital controller , bipolar , 12v dc , input pulse 5v, step angle 1 point 8 , power supply 230 v ac , oprating condition 0 to 40 deg c , bldc motor fan with controller 40 watt , servo motor with contoller 300rpm,12v dc,6mm dia and 15mm legth shaft ,holding torque 30kg cm,no load current 0 point 8 amp,full load current 7 point 5 amp , electrical test bench integrated with 0 to270v ac variac 25a , synchronization trainer for laboratory , solid flow measurement set up bi facial solar panel 550 watt,efficiency 21.3 percentage,dimension 2285mm x 1134mm x 35 mm,anodized aluminumsilver frame,connector mc4 ev02,maximum system voltage 1500v dc, topcon solar panel 610 watt,efficiency 22 point 6 percent to 22 point 9 percent,n type topcon,dimension 2382x1134x30 mm,2 mm dual glass,maximum system voltage 1500v dc, cut section of gate valve,globe valve,ball valve,diapharm valve,needle valve,check valve,safety valve,butterfly valve,pnematic control valve 4 inch diameter, cut section of centrifugal pump,gear pump,multistage c f pump,reciprocating pump,screw pump, cut section of shell and tube heat exchanger acrylic material, cut section of reactor with accessories motor,agitatot,support leg,nozzle,manhole,baffels,thermo well,bottom valve, vrf or vrv unit with two indoor unit 2 point 5 tr each and 5 tr capacity out door unit complete with air cooled condenser,accessories and controls,harmetic shield type compresor,r410 a //bid details 2 / 25
Tender For fabrication, erection and commissioning of damaged ac ducts and damaged condensercoils at armcue rig. - : fabrication, erection and commissioning of damaged ac ducts and damaged condensercoils at armcue rig