Get complete information related to latest Condenser Water Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Condenser Water Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Condenser Water Pump Tenders.
Tender For supply of spares for maintenance of ihc holland dredge - locking ring duo - cone seal 431, 5767372 , locking ring duo - cone seal 432, 5767373 , liquidyne groove bush- steel-wa160-l 95mm-cw-id 126mm, 110024916 , threaded liner shaft sleeve pn.227, 57040957 , spacer pos 605, 50402653 , liquidyne lip seal, wa 600, pos 228, 02232160 , liquidyne spring seal for -wav160 part no- 02232164 , slotted head screw pos no 109, m6x10 pt no.00278045 , hex head bolt pos.no 121 pt no.00142858 m16x55mm, 00142.858 , washer pos no 124, 55089111 , throttle plate pos.no 144, wa160, 57005985 , hex. head screw pos.no 131 pt no.00141854 m16 45m , hex head socket screw pos.no 136 pt no.00252734 m12 40mm , o ring pos.no.126, d 13mm,l 2375 , o ring pos.no.127 pt.no l 1081,d 6mm , liquidyne pos.no 220 , o ring pos.no.625 d 6mm,l 970, 20851.379 , o ring pos.no.685 d 6mm, l 417, 20851.379 , o ring pos.no.686 d 3mm, 20851.376 , spud dia 559-2860100 , pump wear plate shaft side part no -112, 5903880, 57010961 , suction shaft side cover part no - 111, 50402359 , pump wear plate suction side part no - 113, 57010961 , nozzle liner part no -163, dz 350 200 mm, 57012.007, 57012137 , shaft cover part no - 150, 50401048 , hydraulic cylinder sa- 110by90degree2100 , bend 45 deg sl1, 380 dia , straight pipe sl2, 380 dia , bend 45 deg sl3, 380 dia , bend 45 deg s1, 380 dia , straight pipe s2, 380 dia , s3- bend 33.5 s3, 380 dia , stand pipe spbyep2, drn no. 2724100 , 90 deg spbyep2 d1 , bend 45 d4 , straight pipe d5 , bend 45 d6 , replacement pipe d7 , compensator rubber 80mm dia , oil water cooler for ambuja dredge p.20.2pl 600 mv , seal duo - cone, mechanical face seal, goetze-76.90 , coupling saec 12by24db z 14 inc.seals fitted between gear box and hyd pump , main pump bearing assembly with pedstal part no - 699, 100405357 , thrust ring pt no.110 pt no.57005997 , bonded seal dowty ring pos no 122 pt no. 02176032, d 51.70 , bonded seal dowty ring pos n 123 pt no.02176017, d 19.65 , bucket wheel cutter part no - bw 2410 pt no.301, 5246883 , pump casing part no -103, dn.50402346,an.57008969 , pump impleller 75-25-35 3bl wa 160 part no -105, 57015975 , suction mouth suction line part no -dn.50402204, pos 100 , sleeve pos 615,57032111
Tender For tender for supply of operation of water cooled centralised ac plant of 3x330 tr trane make and all associated ancillary equipments and ventilation fans etc. round the clock in 3 shifts on all days iincluding sundays and holidays by deputing supervisor , shift in-charge or skilled , semi skilled manpower etc. complete as required and as per enclosed detailed specifications. for first year , operation of water cooled centralised ac plant of 3x330 tr trane make and all associated ancillary equipments and ventilation fans etc. round the clock in 3 shifts on all days including sundays and holidays by deputing supervisor , shift in-charge or skilled , semi skilled manpower etc. complete as required and as per enclosed detailed specifications.for second year , comprehensive maintenance contract for the centralized air-conditioning system consists of 330tr water cooled chiller units (trane make)-03 nos. , chilled waterpumps primary pumps (kirlosakar make)-3 nos. and secondary pump (grundfoss make)- 3 nos. with vfd drive panel , condenserwaterpumps (crompton make) - 3 nos. , cooling towers (advance make)-3 nos. , chilled water and condenserwater lines , air handling units (floor mounted and ceiling suspended) (zeco make) with starter panels - 27 nos. power and control panels and its associated equipments like bearings , v-belts , canvas , valves (excluding the butterfly valves) , strainers , dampers , diffusers , grills , nozzles , thermostats , switchgears in control panels(excluding the power cables) , ventialation fans of toilets , electrical meters , contactors , timers etc. complete as required for smooth operation of the complete hvac system. the scope of work also includes carrying out the periodical maintenance/checking of the above equipments & maintenance of water softening plants along with supply of salt for operation as per manufacturers recommendations and/or as per the attached technical conditions. for first year , comprehensive maintenance contract for the centralized air-conditioning system consists of 330tr water cooled chiller units (trane make)-03 nos. , chilled waterpumps primary pumps (kirlosakar make)-3 nos. and secondary pump (grundfoss make)- 3 nos. with vfd drive panel , condenserwaterpumps (crompton make) - 3 nos. , cooling towers (advance make)-3 nos. , chilled water and condenserwater lines , air handling units (floor mounted and ceiling suspended) (zeco make) with starter panels - 27 nos. power and control panels and its associated equipments like bearings , v-belts , canvas , valves (excluding the butterfly valves) , strainers , dampers , diffusers , grills , nozzles , thermostats , switchgears in control panels(excluding the power cables) , ventialation fans of toilets , electrical meters , contactors , timers etc. complete as required for smooth operation of the complete hvac system. the scope of work also includes carrying out the periodical maintenance/checking of the above equipments & maintenance of water softening plants along with supply of salt for operation as per manufacturers recommendations and/or as per the attached technical conditions. for second year , painting of hvac system such as pumps , cooling tower- motors , pedastal and other equipments by removal of corrosion with sand paper and painting with corrosion resistant paint to match the adjoining areas for maintaining the equipment in good and non rusting condition. for first year , painting of hvac system such as pumps , cooling tower- motors , pedastal and other equipments by removal of corrosion with sand paper and painting with corrosion resistant paint to match the adjoining areas for maintaining the equipment in good and non rusting condition. for second year , repairing damaged insulation of exposed ac ducts by scrapping and cleaning the surface , applying cold bitumin or adhesives , supplying and fixing of 50mm thick thermo coal sheet (eps) and wraped canvas clothes with suitable self adhesive as per the specif