Get complete information related to latest Condensers Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Condensers Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Condensers Tenders.
Tender For corrigendum : replacement of em items against ber held with ge i rnd east bangalore - supply, installation, testing & commissioning of double skin horizontal air handling unit of fully capacity, complete with double skin insulated with cfc free foam (puf) panels of 25mm thick, 42 kg/cum density. sandwitched between 0.6 mm thick g.i. sheets. outer skin shall be pre coated g.i. sheet pre coated off white. ahu frame works shall be of pre cast vertical and horizontal extruded aluminium profile with three way corner frame sections. frame construction should bear the load of structure and load of the frame structure shall be uniformly distributed along the entire housing of the ahu. food grade self adhesive coated neoprene gasket to be provided between panels and structure of the ahu to ensure the entire housing is airtight., backward curved blower to be supplied along with motor (kruger/nicotra). filter will be of 10 mic as pre filter, 3 mic as fine filter. cfm as below with 60-80mm sp complete all as specified and directed., note: rate quoted to be deemed to include civil works for hvac like breaking and opening for entry and exit of supply ducts from ahu room, exhaust ducts into shafts for exiting copper pipes / drain pipes also. fire rated material of 25mm thick phenotherm to be used near civil closures for fire resistant properties., a) 13200 cfm, 60mm static ahu capacity 33 tr., 11 tr dx outdoor ac unit complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a minimum capacity.note: rate quoted to be deemed to erection of condenser unit platform (ms angle frame with 02 coats of red-oxide and 01 coat of enamel black paint) with ms works for duct support., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 22 tr ducted packaged ac unit with 8800cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 11 tr ducted packaged ac unit with 4400cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 8.5 tr ducted packaged ac unit with 3500cfm complete all as specified and directed., supply, installation, testing & commissioning of air cooled ducted split air conditioners of capacity 8.5 tr with r2 series: r 407c eco friendly refrigerant, nominal cooling capacity 1,02,000 btu/hr, nominal air flow 3400 cfm, microprocessor based with lcd display controller and hermetically sealed scroll type compressor, all necessary connections with suitable size of copper cables and initial gas charging, provision of necessary pcc platform / iron angle frame for outdoor unit complete all as specified and directed by engineer-in-charge., dismantling / taking down / transporting carefully old acs outdoor & indoor unit with all connected acessories and to be deposited in mes store complete all as specified and directed., dismantling / taking down / transporting carefully old unserviceable ducting items off any size and capacity with all connected accessories and to
Tender For ttps operation circle mpm ii acp stage i ii iii cleaning of filters cooling coils condensers cooling towers and greasing of bearings in ac plants and periodical overhauling of pumps equipments from 01.04.2026 to 31.03.2027
Tender For corrigendum : expression of interest is invited for engine alternator coupling modification and alternator control upgrade for dual operation as synchronous condensers in conventional drilling rigs of ongc assam asset
Tender For supply of maintenance of turbine and its auxiliaries of btps obra d d - 51 to 100 , attend flange or bonnet lkg of hp valve or hp pipe101 to 150 , attend flange or bonnet lkg of hp valve or hp pipe151 to 200 , oh of by pass valve of temp control line or patch welding work in the condenser or hot tightening of ejector , clean of filter of tur oil or h2 cooler str , oh of main steam line valve i. e. v2 6 , oh of feed line valve with by pass valve , oh of nrv of extraction line, es-1 or es-2 or ipt transfer pipe line drain valve , oh of nrv of extraction line,es-8 or es-11 or oh of nrv of hp drip or cep disch line , oh of valve cont. to cond dw-4 or 38- 41 or ca-5 or as-47 or as-48 valve , oh of stm throw valve to cond or iso lph-2 , oh of steam by pass valve v2-27 or 15 or v2-7 , oh of extrac valve i. e. es-3 or 4 or 5 or 6 or 7 or oh of drip line gate valve hd-21or 29 or 30 or 31 , oh of fcnrv or isolating valveof lph-3 or 4. , oh of condensate throw off valve to cond , rep of es-9 by h. p welding tech, , rep of v227 or 15 by h. p welding tech, , rep of v2-38 or 81-84 by h. p welding tech, , oh of actuators of msv-l or r , oh of actuators of dw-4 or 38- 41 or ca-5 or cst makeup valve or es-3 to7 or hd-21 or hd-29 to 31 or as 47 or 48 , oh of actrs of v2-38 or 81-84 or 27 or 15 or v2-7 or steam iso valve lph-3 or 4 , oh of actrs of butterfly valve , oh and revisioning of lph-2 to lph-4 or gc-i or gc-ii or lph-1a or lph-1b , oh of gauge glass of lph or gc or ejc or dea o rcon , tight. of flange of crh or gc-i or ii or lph , overhauling of dss of aux. , prds-ii , overhauling of main flash tank , overhauling of aux flash tank , repair or replacement of broken hanger. , tightening of loose hangers. , attend the flange leakage of crh line. , serv of hydr. brake of chit or gar crane , chk and grs. of brg,cplg,chang bush of bolt or serv of greep brake of chit or garlic crane or sevicing servicing of all the wheel of garlic or chitram crane and plate , oh of small hook of chit or garlic crane or oh main hook , serv. of all gear boxes of chit or gar crane , check and clean of wire rope drum or bearing , oh of dss of aux. prds , cut and weld and repl of lp valve up to 50 mm , cut and weld and rep of l. p. valve51 to 100mm , cut and weld and rep of l. p. valve101 to 150mm , oh of isolating or bypass valve of pcv 5 or 14 or 17 , oh of valve contd to dea at 13 mtr v2-21 or cst makup valve , oh of suc valve of bfp or disch valve of cep , oh of suction valve of cep or mc-18-25 or 33 or 37 or oh of u bend valve , fab of reducer for hp drip 218-80 or 168-80 , rep of reducer of h. p drip line , lph drain line valve hd-8 or 9 or 14-19 or 20 , check and rect of internal fault of dea , blanking of crh line for reheater ht , rem chocking oil drain of brg1 or 2 of tur. , rem chocking of drain of cntg. machine. , repl of damaged nrv of pcv-14 or 17 size200 , repl of damaged nrvof feed line size-250 , oh of butterfly valve of condenser , hot tightening of cross over pipe , oh of hp heater and attend of flange lkg. , attending the shell joint of hph , attend the spot lkg of hph shell joint. , oh of safety valve of flange or stud heatng or lp heater or hp heater or cbd tank , oh of safety valve of warm up line , oh of safety valve of aux prds or deaerator or oh of nrv of aux rpds heat line to fst , oh of nrv v2-52 or v2-53 or v280 , oh of nrv of re-circulation line of bfp or spindle leak off line , oh of h. p. valve and nrv. , oh of h. p. steam drain line valve. , rep of nrv of hph drip to deaerator , welding of crack in hph or crh pipe line , fab of bend for recirculation line or oh of group protection valve i. e. fw-1 , fab of bend for hph drip line con to dea , fab of bend of lph drip to drip pump or condenser , rep of bend of hph drip line con to dea , rep of bend of rc line con to dea or oh of //bid details2 / 106feed pump energy absorber. , rep of bend of lph drip to drip pump or condenser , cutting and welding of h. p. valve 15 to 50mm , cutting an