Get complete information related to latest Conductor Bell Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Conductor Bell Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Conductor Bell Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40514286 Due date: 17 Jun, 202517 Jun, 2025 NA
Tender For work of enhancement of current carrying capacity of 132kv hatia ii ckt i and ii double circuit transmission line by replacing acsr panther conductor to acsr moose conductor of 132 33kv grid sub station hatia i.

corporations/Associations/Others

CTN :40506197 Due date: 20 Jun, 202520 Jun, 2025 41.56 Lacs
Tender For work of erection of 66kv d/c lilo line at proposed 66kv vasna (vatam) s/s from existing 66kv s/c agthala-kotda(f) line on d/c panther tower with acsr panther conductor under project yojna. (3.00rkm)

corporations/Associations/Others

CTN :40520553 Due date: 19 Jun, 202519 Jun, 2025 87.60 Lacs
Tender For work of erection of balance work of 66kv s/c line on h frame from 66kv sadla s/s to 66kv umarda s/s with acsr panther conductor under kisan suryoday yojana.

corporations/Associations/Others

CTN :40520574 Due date: 19 Jun, 202519 Jun, 2025 1.11 Crore
Tender For tender for erection of 66kv lilo of one ckt i.e ckt no -2 of 66kv d/c alampar -nagadka line at 66kv chachka s/s on d/c tower with acsr panther conductor having route length 12.84 rkm

corporations/Associations/Others

CTN :40529089 Due date: 19 Jun, 202519 Jun, 2025 81.09 Lacs
Tender For stringing on 2nd circuit of existing 66kv kansari luvarimoli with acsr panther conductor and (2) erction of new 66kv lilo to proposed 66kv kandhi s/s (ta.: gir gadhada, dist.: gir somnath) from proposed 2nd circuit of 66kv kansari luvarimoli line, on d/c panther tower with acsr panther conductor, under construction division junagadh

State Government

CTN :40528370 Due date: 10 Jun, 202510 Jun, 2025 5.50 Lacs
Tender For replacement of acsr panther conductor

State Government

CTN :39231539 Due date: 04 Feb, 202504 Feb, 2025 140.34 Crore
Tender For corrigendum : construction of newly proposed 2x80mva, 132/33 kv gss majorganj (block-majorganj, district-sitamarhi) with construction of lilo of 132kv sitamarhi-dhaka single circuit transmission line (line length- 26 rkm) at proposed gss majorganj with acsr panther conductor and construction of 132 kv dcds sheohar-majorganj transmission line (line length- 28 rkm) with acsr panther conductor along with 02 nos. line bays at gss sheohar.

corporations/Associations/Others

CTN :39202100 Due date: 04 Jun, 202504 Jun, 2025 36.23 Lacs
Tender For corrigendum : balance work of erection of 66kvs/c motigop morzar line with acsr panther conductor having length 7km

corporations/Associations/Others

CTN :40240903 Due date: 09 Jun, 202509 Jun, 2025 73.46 Lacs
Tender For corrigendum : tender for erection of 66kv s/c from 66kv moti vavadi to proposed 66kv jalila s/s line on d/c tower with acsr panther conductor having route length 7.6 rkm

CTN :40221359 Due date: 07 Jun, 202507 Jun, 2025 NA
Tender For corrigendum : rate contract for supply of electrical spares n minor store/hardware items, as given in the detailed boq, from govt approved reputed experienced competent n financially sound electrical contractors/firms/suppliers/joint ventures/executors/oems - part: (a) 132kv transmission lines (material ), al. alloy as per is: 617 of 1975 pg clamps 3 bolt type conforming to is: 5561-1970 (amended upto date) for acsr zebra conductor (make: rul, zi, honeywell, burma, pee, equivalent etc/ as per departmental sample provided)., p g clamp for acsr panther conductor as per relevant is/iec amended upto date and of reputed/standard make, p g clamp for acsr moose conductor as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic ct clamp (universal take off) for panther conductor with ct terminals suitable for 132kv/33kv cts as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic isolator pad clamp (universal take off) of panther conductor with pad terminals suitable for 132kv /33kv isolators as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic isolator pad clamp (universal take off) of zebra conductor with pad terminals suitable for 132kv /33kv isolators as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic breaker pad clamp (universal take off) of zebra conductor with pad terminals suitable for 132kv /33kv breakers of sf 6 type-abb,cgl, siemens, bhel/vcb type- s&s, gec alsthom, bhel, abb, siemens, megawin etc as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic ct pad clamp (universal take off) for twin acsr zebra conductor with conductor spacing 300mm and ct terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin zebra conductor with pad terminals suitable for 132kv /33kv ct as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic twin isolator pad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) for twin acsr zebra conductor with conductor spacing 300mm and isolator pad clamp terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin zebra conductor with pad terminals suitable for 132kv /33kv isolator as per relevant is/iec amended upto date and of reputed/standard make, bimetallic ct pad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) for twin panther conductor with conductor spacing 300mm and ct terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin panther conductor as per relevant is/iec amended upto date and of reputed/standard make, bimetallic breaker pad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) for twin panther conductor with conductor spacing 300mm and terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin panther conductor as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic isolator pad clamp (univercial take off) conforming to is: 5561-1970 (ammended upto date) for twin panther conductor with conductor spacing 300mm and isolator terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin panther conductor with pad terminals suitable for 132kv /33kv isolator of reputed/standard make, bi-mettalic isolator pad clamp (univercial take off) conforming to is: 5561-1970 (ammended upto date) for single panther conductor of reputed/standard make, t-clamps 3 bolt type conforming to is: 5561-1970 (amended upto date) for acsr -panther-acsr panther conductor of repute