Get complete information related to latest Conical Filter Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Conical Filter Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Conical Filter Scrap Tenders.
Tender For state scheme (nabard)/25-26/jhanjharpur/01 - 1) construction of hl rcc bridge in karhara to malleh road over bhutia balan river-ch-2.10 km, earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. upto 3.000 m depth, providing and constructing temporary island 16 m diameter. all complete job as per specifications and direction of e/i., providing service road etc. all complete job as per specifications and direction of e/i., providing steel liner 6 mm thick for piles including fabricating and setting out as per detailed drawing., bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m., dismantling of reinforced concrete pile head complete as per drawing and technical specification, providing and laying of pcc m15 levelling course 100mm thick below the pile cap., cement concrete for reinforced concrete m - 35 in pile cap complete as per drawing and technical specification, supplying, fitting and placing un-coated hysd bar reinforcement in foundation complete as per drawing and technical specifications., providing rcc m-30 mechanically mixed concrete in sub structure with stone aggregate 20 mm nominal size and clean coarse sand of fm-2 all complete job as per design upto 5 m hieght, supply fitting & fixing elasto-meric bearing & seismic pad :-- supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., providing weep holes in abutment cap with 100mm dia ac pipe:-- providing weep holes in brick masonry/plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia ac pipe, extending through the full width of the structure with slope of 1v :20h towards drawing foce. complete as per drawing and technical specifications., supplying, fitting and placing hysd bar reinforcement in substructure complete as per drawing and technical specification., back filling behind abutment, wing wall and return wall, complete as per drawing and \technical specification.(sandy material ), providing and laying of filter media with granular materials/stone crushed aggregate satisfying the requirement laid down in ci. 2504.22 of morth specification of not less than 600mm behind abutment, wing and return wall to the full height compacted., providing rcc m 30 grade & super structure :-- furnishing and placing reinforced/ prestressed cement concrete in super-structure as per drawing and technical specification beyond 5 m and upto 10m hieght (t beam slab), providing hysd bar in all types of rcc work:-- supplying, fitting and placing hysd bar reinforcement in super-structure complete as per drawing and technical specifications ., wearing coat :-- providing and laying cement concrete wearing coat m-30 grade including reinforcement complete as per drawing and technical specifications, providing rcc m30 grade in railing:-- construction of precast rcc railing of m30 grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical rcc post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications., providing drainage spout:-- drainage spouts complete as per drawing and technical specification, providing pcc m15 grade below approach slab:-- pcc m15 grade leveling course below approach slab complete as per drawing and technical specification, providing pcc / rcc m30 in approach slab:-- reinforced cement concrete approach slab including
Tender For state scheme(nabard)/25-26/kishanganj-2/02 - construction of rcc h.l. bridge in t05 to raipur to jharkhuda path (mmgsy) ch-0.030 km, h.l. bridge work, foundation, excavation for structures, earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material., i) upto 3m depth, providing and laying of pcc m15 levelling course 100mm thick below the pile cap., ii. pcc grade m-15 (levelling course for pile cap), r.c.c. grade m 30 in pile foundation complete as per dwg & tech specification., pile cap in rcc m-30 (using batching plant, transit mixer and concrete pump), bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m., ii. 1200 mm dia (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawings and technical specifications clauses 1000 and 1202, providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing, providing and constructing temporary earth island (assuming depth of water 1.0 m and height of island to be 1.25 m including royality for earth, providing and constructing one span service road to reach island location from one pier location to another pier location including royality for earth, carrying out load test on any pile as per standard procedure laid down in the is:2911 specification including construction of test cap, dismantling the cap after test and cleaning the site and maintaining complete records of load, a) initial load test on test pile for 2.5 times the design load specified in drawings, 1.2 m dia pile, b) routine pile load test on pile for 1.5 times the design load specified in drawings, 1.2 m dia pile (2% of piles in total)., c) horizontal pile load test on pile for 1.5 times the design load specified in drawings, 1.2 m dia pile (2% of piles in total) ., substructure, r.c.c. grade m-30 in substructure complete as per dwg & tech specification, i) upto 5m height (using batching plant, transit mixer and concrete pump), ii) from 5m upto 10m height (using batching plant, transit mixer and concrete pump), r.c.c. grade m-35 in substructure complete as per dwg & tech specification, ii) from 5m upto 10m height (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement (fe 415) in substructrue complete as per drawings and technical specification clauses 1002, 1005, 1010 & 1202, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia ac pipe extending through the full width of the structures with slope of 1(v):20(h) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7, backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8, i) sandy material, providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8, superstructure, providing and laying reinfo
Tender For state scheme(nabard)/25-26/kishanganj-2/01 - construction of rcc h.l. bridge in malgachh to lat at ch.-0.600 km., h.l. bridge work, foundation, excavation for structures, earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material., i) upto 3m depth, providing and laying of pcc m15 levelling course 100mm thick below the pile cap., ii. pcc grade m-15 (levelling course for pile cap), r.c.c. grade m 30 in pile foundation complete as per dwg & tech specification., pile cap in rcc m-30 (using batching plant, transit mixer and concrete pump), bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m., ii. 1200 mm dia (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawings and technical specifications clauses 1000 and 1202, providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing, carrying out load test on any pile as per standard procedure laid down in the is:2911 specification including construction of test cap, dismantling the cap after test and cleaning the site and maintaining complete records of load, a) initial load test on test pile for 2.5 times the design load specified in drawings, 1.2 m dia pile, b) routine pile load test on pile for 1.5 times the design load specified in drawings, 1.2 m dia pile (2% of piles in total)., c) horizontal pile load test on pile for 1.5 times the design load specified in drawings, 1.2 m dia pile (2% of piles in total) ., substructure, r.c.c. grade m-30 in substructure complete as per dwg & tech specification, i) upto 5m height (using batching plant, transit mixer and concrete pump), ii) from 5m upto 10m height (using batching plant, transit mixer and concrete pump), r.c.c. grade m-35 in substructure complete as per dwg & tech specification, ii) from 5m upto 10m height (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement (fe 415) in substructrue complete as per drawings and technical specification clauses 1002, 1005, 1010 & 1202, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia ac pipe extending through the full width of the structures with slope of 1(v):20(h) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7, backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8, i) sandy material, providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8, superstructure, providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5, ii. rcc m-30 (using batching plant, transit mixer and concrete pump), supplying, fitting and placing hysd bar reinforcement (fe 415) in superstructrue complete as per drawings and technical sp
Tender For supply of bioculture for stp , sodium hypo chloride , polyaluminium chloride solution , activated carban filter for acf filter , quartz silica and sand 16 to 32 , quartz silica and sand 8 to 16 , quartz silica and sand 16 to 64 , mbbr media k1 bio filter
Tender For bid to ras supply of supply and fixing of automatic bar screen , supply and fixing of sewage transfer pumps , supply and fixing of dissolved air flotation system , supply and fixing of fog free water transfer pumps , supply and fixing of fog transfer pumps , supply and fixing of bio media mbbr stream 1 and 2 , supply and fixing of tube settler media settling tank 1 and 2 , supply and fixing of air blower with motor , supply and fixing of diffusers for aeration tank stream 1 and 2 , supply and fixing of diffusers for anoxic tank stream 1 and 2 , supply and fixing of filter backwash pumps 1 working 1 stand by , supply and fixing of do indicating controller cum transmitter , supply and fixing of pressure sand filter , supply and fixing of activated carbon filter , supply and fixing of basket strainer , supply and fixing of dosing system , supply and fixing of flow meter emf , supply and fixing of flow meter , supply and fixing of gratings , supply and fixing of level switch , supply and fixing of sludge fog and f fat, oil, grease and floatables compactor , supply and fixing of sludge dryer , supply and fixing of 100mm dia upvc pipe , supply and fixing of 80mm dia upvc pipe , supply and fixing of 63mm dia upvc pipe , supply and fixing of 50mm dia upvc pipe , supply and fixing of 4 inch butterfly valves , supply and fixing of 3 inch butterfly valves , supply and fixing of 2 and half inch butterfly valves , supply and fixing of 2 inch butterfly valves , supply and fixing of 4 inch flop type , supply and fixing of 3 inch flop type , supply and fixing of 2 and half inch flop type , supply and fixing of 2 inch flop type , supply and fixing of mf backwash pump , supply and fixing of bag filter , supply and fixing of strainer , supply and fixing of micro filtration module , compressor for automation valves and mf air scoring , supply and fixing of automation panel , supply and fixing of automation valve , supply and fixing of automatic reject control valve , supply and fixing of air relief valve , supply and fixing of air flow meter , supply and fixing of pressure gauge , supply and fixing of pressure transmitter for mf , supply and fixing of cip pump , supply and fixing of mf skid , sitc of electrical panel 125a panel 1 , sitc of electrical panel 125a panel 2 , sitc of electrical panel 125a panel 3 , supply and fixing of lt cable 2c x 1 point5 sq mm , supply and fixing of lt cable 3c x 1 point5 sq mm , supply and fixing of lt cable 2c x 2 point5 sq mm , supply and fixing of lt cable 3c x 2 point5 sq mm , supply and fixing of lt cable 3c x 4 sq mm , supply and fixing of lt cable 3c x 6 sq mm , laying of lt cable 35 sq mm , supply and fixing of lt cable 300mm x 50mm x 1 point 6mm , supply and fixing of lt cable 100mm x 50mm x 1 point 6mm bid details/ 2 / 61
Tender For state scheme (nabard) /25-26/tikari /01 - 1) name of work: construction of high level rcc bridge over morahar river in between mahiyarpur to kurmawaan, earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. upto 3.000 m depth, providing and constructing temporary island 16 m diasmeter all complete job as per specifiactions and direction of e/l, providing service road etc. all complete job as per specifications and direction of e/i., providing steel liner 6 mm thick for piles including fabricating and setting out as per detailed drawing., bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m., dismantling of reinforced concrete pile head complete as per drawing and technical specification, providing and laying of pcc m15 levelling course 100mm thick below the pile cap., cement concrete for reinforced concrete m - 35 in pile cap complete as per drawing and technical specification, supplying, fitting and placing un-coated hysd bar reinforcement in foundation complete as per drawing and technical specifications., providing rcc m30 mechanically mixed concrete in abutment shaft & pier shaft with stone aggregate 20 mm nominal size and clean coarse sand of fm-2 .all complete job as per design upto 5 m height, supply fitting & fixing elasto-meric bearing & seismic pad :-- supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications. elastomeric bearing & pad, providing weep holes in abutment cap with 100mm dia ac pipe:-- providing weep holes in brick masonry/plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia ac pipe, extending through the full width of the structure with slope of 1v :20h towards drawing foce. complete as per drawing and technical specifications., supplying, fitting and placing hysd bar reinforcement in substructure complete as per drawing and technical specification., back filling behind abutment, wing wall and return wall, complete as per drawing and \technical specification.(sandy material ), providing and laying of filter media with granular materials/stone crushed aggregate satisfying the requirement laid down in ci. 2504.22 of morth specification of not less than 600mm behind abutment, wing and return wall to the full height compacted., providing rcc m 30 grade & super structure :--furnishing and placing reinforced/ prestressed cement concrete in super-structure as per drawing and technical specification beyond 5 m and upto 10m hieght (t beam slab), providing hysd bar in all types of rcc work:-- supplying, fitting and placing hysd bar reinforcement in super-structure complete as per drawing and technical specifications ., wearing coat :-- providing and laying cement concrete wearing coat m-30 grade including reinforcement complete as per drawing and technical specifications, providing rcc m30 grade in railing:-- construction of precast rcc railing of m30 grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical rcc post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications., providing drainage spout:-- drainage spouts complete as per drawing and technical specification, providing pcc m15 grade below approach slab:-- pcc m15 grade leveling course below approach slab complete as per drawing and technical specification, providing pcc / rcc m30 in approach s