Get complete information related to latest Contact Finger Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Contact Finger Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Contact Finger Tenders.
Tender For supply of supply 765kv 3150a 50ka for 1s 3ph db vertical knee type individual pole motor operated electrically ganged isolator with 1es individual pole motor operated electrically ganged as per ts , supply 765kv 3150a 50ka for 1s 3ph db vertical knee type individual pole motor operated electrically ganged isolator with 2es individual pole motor operated electrically ganged as per ts , supply 765kv 3150a 50ka for 1s 1ph db vertical knee type isolator motor operated with 1es motor operated along with operating mechanism as per ts , supply 765kv 3150a 50ka for 1s 1ph db vertical knee type isolator motor operated without earth switch as per ts , spares isolator 765kv 3150a 50ka for 1shdb vertical knee type isolator one complete pole with 1es along with operating mechanism as per ts , spares isolator 765kv 3150a 50ka for 1s horizontal db hdb vertical knee type isolator copper contactfingers for female and male contacts for one pole , spares isolator 765kv 3150a 50ka for 1s horizontal db hdb vertical knee type isolator open close contactor assembly timers key interlock push button switch and auxiliary switches , spares isolator 765kv 3150a 50ka for 1s horizontal db hdb vertical knee type isolator limit switch , spares isolator 765kv 3150a 50ka for 1s horizontal db hdb vertical knee type isolator terminal pads , spares isolator 765kv 3150a 50ka for 1s horizontal db hdb vertical knee type isolator corona shield rings , services isolator 765kv supervision of erection testing and commissioning including alignment check of 3ph db vertical knee type isolator , services isolator 765kv supervision of erection testing and commissioning including alignment check of 1ph horizontal db hdb type isolator , spares isolator 765kv 3150a 50ka for 1s horizontal db hdb vertical knee type isolator one complete pole with 1es along with operating mechanism as per ts
Tender For corrigendum : supply supply-400kv, 3150a, 63ka for 1s, 3ph, hdb type isolator as per ts , supply-400kv, 3150a, 63ka for 1s, single phase, hdb type isolator as per ts , supply220kv, 3150a, 50ka for 1s, 3ph, bus transfer current switching duty, hdb type isolator as per ts , supply220kv, 1600a, 50ka for 1s, 3ph, bus transfer current switching duty, hdb type isolator as per ts , supply220kv, 1600a, 50ka for 1s, 3ph, hdb type isolator as per ts , supply-220kv, 1600a, 50ka for 1s, 3ph, bus transfer current switching duty, double break, tandem type isolator as per ts , supply-72.5kv, 25ka for 3s, 400a, 3ph, hdb type isolator as per ts , supply-36kv, 25ka for 3s, 400a, 3ph, hdb type isolator as per ts , services-400kv, supervision of erection testing and commissioning including alignment check of hdb type isolator and earthswitch , services-400kv, supervision of erection testing and commissioning including alignment check of single phase, hdb type isolator and es , services-220kv supervision of erection testing and commissioning including alignment check of 3ph, hdb type isolator , services-72.5kv, supervision of erection testing and commissioning including alignment check of hdb type isolator and earthswitch , services-36kv, supervision of erection testing and commissioning including alignment check of hdb type isolator and earthswitch , supply-145kv, 1250a, 40ka for 1s, 3ph, hdb type isolator as per ts , supply-145kv, 1250a, 40ka for 1s, 3ph, hdb, tandem type isolator as per ts , supply-36kv, 25ka for 3s, 400a,3ph, hdb type and etc of 400kv and below rating isolators - isolator as per ts , spares-400kv, 3150a, 63ka for 1s, hdb type isolator - one complete pole with one es along with operating mechanism and other accessories, but without insulator, structure and terminal connector etc. , spares-400kv, 3150a, 63ka for 1s, hdb type isolator - copper contactfingers for female and male contacts for one pole , spares-400kv, 3150a, 63ka for 1s, hdb type isolator - open or close contactor assembly, timers, key interlock push button switch and auxiliary switches as per ts , spares-400kv, 3150a, 63ka for 1s, hdb type isolator - limit switch , spares-400kv, 3150a, 63ka for 1s, hdb type isolator - terminal pads , spares-400kv, 3150a, 63ka for 1s, hdb type isolator - corona shield rings , spares-220kv,1600a,50ka for 1s, hdb type isolator, bus transfer current switching duty -one complete pole with one es alongwith operating mechanism as per ts , spares- 220kv, 1600a, 50ka for 1s, hdb type isolator, bus transfer current switching duty -copper contactfingers for female and male contacts for one pole , spares-220kv, 1600a, 50ka for 1s, hdb type isolator - open or close contactor assembly, timers, key interlock push button switch and auxiliary switches , spares-220kv, 1600a, 50ka for 1s, hdb type isolator - limit switch , spares-220kv, 1600a, 50ka for 1s, hdb type isolator - terminal pads , spares- 220kv, 1600a, 50ka for 1s, hdb type isolator - corona shield rings , spares-145kv, 1250a, 40ka for 1s, double break dbr type isolator -one complete pole with one es alongwith operating mechanism as per ts , spares-145kv, 1250a, 40ka for 1s, double break dbr type isolator -copper contactfingers for female and male contacts for one pole , spares-145kv, 1250a, 40ka for 1s, double break dbr type isolator -open or close contactor assembly, timers, key interlock push button switch and auxilliary switches , spares-145kv, 1250a, 40ka for 1s, double break dbr type isolator -limit switch , spares-145kv, 1250a, 40ka for 1s, double break dbr type isolator -terminal pads , spares-145kv, 1250a, 40ka for 1s, double break dbr type isolator - corona shield rings , services-132kv, supervision of erection testing and commissioning including alignment check of hdb type isolator and earthswitch , supply-400kv, 3150a, 63ka for 1s, 3ph, hdb type isolator individual pole motor operated, electrically ganged with two es as per ts , supply- 400kv, 3150a, 63ka for 1s, 3ph, hdb ty
Tender For supply of porcelain insulators for overhead power lines with a nominal voltage greater than 1000 v as per is 731 , wire; sty, gi, 7/12 swg, in kg , arrester; 7.2kv, 10ka, w/ insulating base , wire; gi, 10swg , rod; stay, 5/8in, gi, w/anchr rod, plt turn
Tender For repair and maintenance of various lwss /tube wells in sub division raja ka talab in tehsil fatehpur distt. kangra h.p. sh- providing electronic star delta timer, contactfinger oil immersed starter of different capacity etc. under crf
Tender For supply of surge voltage arrester (ettfp) 1.5 kv rating for 25 kv single phase 50 c/s electric locomotiv e to clw specn. no. clw/es/a-8. note- material to be procured from clw sources or their authorised delae r only. ]
Tender For installation, testing, commissioning and supply of lcd solar power plant (roof top) for ong rid system, three phase 17kw power with output voltage 415v, complete with solar spv array, module m ounting structure, power conditioning unit (pcu) consisting of maximum power point tracker (mppt), invert er (200v-800v, max output current- 27a) and controls & protections, inter connect cables and switches. sw itching device-igbt, pure sine wave output, ip-65, electric cable for input (pv module to inverter)- 1x4 sq.m m copper cable, lengh-25 mtr, electric cable for output (inverter to net meter)- 3.5x10 sq.mm copper cable , lengh-30mtr, lightning arrester, earthing, danger board, pv module (as per is: 14286) rating- 250-1000wp , no. of pv module- 51 nos., total load on roof- 60 kg per sq.m (max), minimum clearance of structure from roof level- 300mm, suitable to withstand wind pressure of 180km/hr, area required for installation- 180sq. m. installation & testing of the complete system including civil work, designing, cabling work with suitable c lamps & fasteners etc. make- tata power solar, vikram solar, spj solar or similar warranty of solar power pl ant -warranty & guarantee : warranty of pv modules : >/= 25 years from the date of commissioning warra nty of inverter : 8 years from the date of commissioning minimum guarantee for maintaining of output peak watt capacity : >/= 90% at the end of 10 years and >/= 80% at the end of 25 years ]