Get complete information related to latest Contact Tip Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Contact Tip Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Contact Tip Tenders.
Tender For corrigendum : supply of spares for stationary sullair make air compressor of model no.- ls20-125 hh ac, set consists of 4 it ems as (1) reducer elbow rubber (7"x5") (part no.: 250002-802) or equivalent, qty: 01 nos (2) poppet valve ( part no.: 02250060-988) or equivalent qty: 01 nos, (3) kit maintenance fluid filter (part no.: 02250112-478) or equivalent, qty: 12 nos, (4) contacttip set (las -d-3 poles ) lc1d150 (part no.: la5d150803) or equivalent, qt y: 02 sets. (annexure attached.) [ warranty period: 30 months after the date of delivery ]
Tender For equipments for electrical engineering lab.--, , rlc kit, , water analyzer, , solar energy panel - kt, , four point dc motor starter, , single phase transformer, 230/230v, 230/115v, 3kva with tapping at 10%,25%,50% and 75% housed in steel box with educational type terminals provided with control panel (for oc and sc test) consisting of following accessories, , dc compound motor, , single phase, , electrodynamometer wattmeter, , digital portable lcr meter, , single phase variac, , three phase variac, , phase sequence indicator, , synchroscope, , rheostats of various ranges, , meggar (two of each rating), , different types of overhead line insulators(each one), , different types of underground cables, , parallel inverter using scr's (memurray bedford), , step up chopper trainer kits with required capacity of (30v/2a and 220v/5a ratings), , battery charger experimental kit using scr, , experimental kit for speed control of dc series motor (scr based), , synchronous motor, , dc servo motor speed torque characteristics kit, , ac servo motor speed torque characteristics kit, , ac position control system kit, , dc position trainer kit, , synchro transmitter and receiver kit, , linear system simulator (open loop & close loop system of first order & second order systems), , cut sections and charts, , hrc fuse, , d.o.l.. starter (for induction motor) trainer kit with overcurrent relay, , three phase power factor meters, , insulation tester, , single phase wattmeter, , clamp ammeter kit, , dso, , sr, d, jk and t flip-flop (each two), , common emitter transistor set, , analog to digital converter interface card, , 4 digit seven segment display interface card, , dac kit, , temperature measurement & controller card, , 8086 microprocessor trainer kit for study, , intel 8051 microcontroller kit with data card, , nd converters experimental kit (adc 0800 series), , led display kit with card, , lcd display kit with card, , monkey wrench/pipe, , wrench, , chisel (farmer chisel & cold chisel), , wire stripper, , hand drill, , drill bits-metal bit reamer, carpentry bits, flat wood bit and masonry bit., , tumbler switch, , dpic switch, , main switch, , sub mail 1 switch, , 2 way 6a switch, , 1 way 6a switch, , single pole double throw, , single pole single throw, , triple pole switch, , metal conduit pipe with junction box, , metal bend, , pvc casing and capping, , pvc bend, , batten lamp holder, , switch boards with socket outlets, , 7/20 swg power wire, , 3/20 swg phase wire, , 3/22 swg neutral wire, , 1/18 swg earthing wire, , flexible cable, , try square, , coil winding machine, , card dynamo for the purpose of armature winding, , 3- phase squirrel cage 2hp induction motor for the armature winding purpose, , small battery charger for assembly and testing purpose, , alarm bell for assembly and testing purpose, , inducting relays for assembly and testing purpose, , coil winding varnish coated wire of suitable gauge
Tender For bid to ras supply of esab mig welding torch (psf 405 plus) (part no: 3m- 4650692924) , make esab , tip adapter m8 (part no: 1651691989) , make esab , contacttip 1.2mm cu cr zr, make esab , gas nozzle std 17mm (part no: 0458464883) , make esab
Tender For corrigendum : purchase of gym for strength and conditioning equipments - endurance sectiontreadmill1. machine must be designed for running with heavy duty 4 hp motor.2. should have low start up speed: 0.5 kmph or lesser.3. should have incline increments of 1% or lesser.4. low step height: 7 or lower.5. speed range: 0-20 kmh or more.6. incline: 0-15% or more.7. max user weight: 180 kgs or more.8. belt size : 61 x 22 or more9. should have at least 10 preprogrammed protocols with option for heart rate range control10. led console with feedback for time distance, calories burnt, heartrate, incline, track and more product should have en-957 or astm certification for stationary fitness equipment, curved non- motorized treadmill (self- powered)1. curved non-motorized treadmill should be capable of training the body s all energy systems as a comprehensive system, capable of offering sprinting for aerobic power development2. curved non- motorized treadmill (self powered) should be capable of offering the sports persons to experience a full speed resistance spectrum.3. variable resistance: the curved non- motorized treadmill (self powered) system should have requisite advanced drive technology enabling users to select different levels of reactive resistance, from zero to max. by simply shifting the drive control system, rehab athletes can quickly switch from resistance-free running to an all-out sled push.4. increased metabolic rate: walking with resistance on said curved non-motorized treadmill (self powered) training system should be capable of enhancing energy expenditure significantly compared to walking at the same speed on a traditional treadmill or a non- motorized treadmill without resistance.5. maximum muscle activation: ergonomic design of the curved non-motorized treadmill (self powered) training system should lead to significantly higher activation of the posterior kinetic chain muscles, particularly the glutes and hamstrings, compared to traditional treadmills.6. curved non-motorized treadmill (self powered)- training system should be capable of being operated and controlled exclusively by the force applied / generated by rehab athletes. in order to speed up, provision should be there, where rehab athlete can move to the front of the surface and to slow down, rehab athlete can move to the back of the said treadmill. provision must be there where the training system can be accelerated quickly from a cold start and matches upto the same pace as the rehab athletes intends to attain. the said system should offer an ideal solution for an eco-sustainable facility, by reducing electricity costs and carbon footprint.7. training system should have requisite technology, ergonomic design and advanced engineering solution so that rehab athletes can work hard in a completely safe training environment.the ergonomic design combined with the high- quality components and materials should be of solid, compact product with a versatile nature that endures well to suit high intensity prolong training sessions to ensure maximum durability and reliability.8. provision for proper posture control:the ergonomic design of training system promotes the correct alignment of the ankles, knees, hips and back, so that user can maintain natural posture at all- times and avoid joint and knee stress, regardless of their height and weight. system should offer the provision of simulating the experience of walking/running uphill while preserving the correct biomechanics.9. accessory kit: the training system must be provided with accessory kit which allows for a variety of pulling and pushing exercises through handles or a waist belt.10. technical specifications:a) dimensions range (lxwxh)*:190-200cmx86- 95cmx150-160cmb) console type: a minimum of 6-7 lcd display with back lightc) power supply: lps 5v wall supplyd) power requirement: 200 - 240 v (should comply with standard indian electrical system)e) resistance control: should have magnetic resistance with a min
Tender For corrigendum : purchase of recovery and rejuvenation lab. - infrared sauna tower irradiance: 55-110 mw/cm2, providing therapeutic benefits rated power: 100-240v ac, 2 amp, 50-60hz, suitable for standard electrical outlets wattage: 350w, combining red light and near-infrared therapy wavelength: 650nm (red light) and 850nm (near-infrared), promoting healing and relaxation led arrays: 70 red light leds (650nm) and 70 near-infrared leds (850nm), ensuring optimal coverage variable optics: 7 60-degree optics for maximum impact and quicker results. emf emissions: no detectable emf emissions at 10-15cm, prioritizing user safety. infrared sauna units with below mentioned features to be preferred- heaters: full spectrum heaters (400w each) or carbon fiber heaters (up to 2160w total power) temperature control: digital temperature and time control for customizable sessions materials: canadian hemlock wood or western red cedar, known for durability and hypoallergenic properties additional features: bluetooth connectivity, chromotherapy lights, and built-in stereo speakers for an enhanced experience. energy efficiency: reduced electricity consumption for cost-effective use temperature range: operating temperatures between 115 f and 140 f for comfortable sessions safety features: person-specific designs and low emf emissions for safe use, cryotherapy chamberwhole body cryo therapy chamber that runs completely on electricity without need of liquidnitrogen low temperatures within the range: -130 to -140 degree celsius. multiple treatment options electric mechanical lift system ensures user s head is outside the chamber to prevent exposure to cryogenic temperatures. real-time skin temperature monitoring using ir tech sensors ensuring safe and controlledcooling. smart software that manages the treatment processes throughout each session. simple quick plug-and-play set up without requiring specialized ventilation. large uhd touchscreen for easy operation and control. at least 3 media monitors for displaying media content. hifi speakers for audio entertainment and ambient audio. work on normal indian 220v at 16a or less, whole-body pneumatic lymphatic drainage machine:key features- multi-chamber design: multiple chambers that inflate and deflate in sequence to mimic manual lymphatic drainage- adjustable pressure: adjustable pressure settings to accommodate different patient needs and comfort levels- programmable treatment: programmable treatment protocols for customized therapy sessions- user-friendly interface: intuitive interface for easy operation and programming- input voltage: ac110v/220v- power consumption: less than 400w- screen: 8-inch wide color touch screen- air pressure: 20-360 mmhg (max pressure 37.5kpa)- cooling device output temperature: 5 to -16 c- output vacuum pressure: 0-110kpa- default time: 0-60 minutes- fuse size: f3al250v- ambient temperature: 5 c to 42 c- number of air bags: 24 bags or 16 pairs atleast - treatment modes: 4 modes atleast - intensity levels: 3 levels- package size: 62x42x31cm approx - gross weight: 15 kg approxsafety features- automatic pressure adjustment: automatic pressure adjustment to prevent excessive pressure and ensure patient comfort- emergency stop: emergency stop feature to quickly deflate chambers in case of discomfort or distress- patient monitoring: optional patient monitoring capabilities to track vital signs and treatment responseadditional features- multiple treatment modes: multiple treatment modes for different conditions, such as lymphedema, edema, and post-surgical swelling- data logging: optional data logging capabilities to track treatment parameters and patient progress- portability: optional portable design for increased flexibility and convenience.certifications: ce or fda clearance, percussion massager (gun massager)key features- percussive action: a percussive action that provides rapid and repetitive strokes to muscles and tissues- adjustable speed: adjustable speed settings to cust
Tender For corrigendum : purchase of biochemistry lab equipments - fully automatic biochemistry analyzerthroughput: 200 photometric tests/hour & 400 tests/hour with ise (optional)reagent positions: 50 cooled reagent positionssample type: whole blood, serum, plasma, urine, csf otherreading volume: 180 lsample volume: 2-70 l (adjustable in 0.1 l)reagent volume: 10-300 l (adjustable in 1 l)light source: halogen lampon board laundry: 6 stage cleaning, 2 stage drying with cuvette validation stepcalibration type: linear, non-linear, multipointprogrammable parameters: default system pack parameters + upto 10 user defined parametersdimensions and weight: ergonomic design and light weight., fully automatic hematology analyzerthroughput-up to 80 samples per hourdimensions and weight ergonomic design and light weighttest mode-cbc, cbc+diffdata storage capacity-up to 100 000 resultscommunication-lan port supports hl7 protocolpower requirement-a.c. 100-240 v, less than or equal to 300 va, 50/60 hzoperating temperature-15 to 30 degree celsiusoperating humidity-30-85%air pressure70-106 kpa, fully automatic immunoassay analyser random assay (hormone analyser)instrument name: immunoassay analyserusage/application-clinicalplate format-random assaydetection method-luminescenceparameters-blood alcohol contentautomation-fully automaticuser input-touchassays-diabetes, thyroid, cardiac, vit d, fully automatic electrolyte analyser-analysis time: 60 second per sample parameters- na , k , cl or ca2+no. of parameters 3 simultaneously90 luser inputs 5 colored touch screen displayelectrode type- sturdy electrode (facility to refill the solution)connectivity 2 usb port, rs232, lisdata storage- 10,000 patient results & 10,000 qc results for 3 levelssample identification- alphanumeric sample idqc management- tri-level quality control, l j plots of last 30 dayscalibration- 2 point calibration on every 4 hours1 point with every samplepower - 100 240 v, 50/60 hz (self adjusting)printer - inbuilt thermal printerroom temperature -15 30 c / 60 90 fhumidity- 85%dimensions and weight - ergonomic design and light weight, centrifuge machine along with 500 prp test tubes (double spin)parameter- neya-16 max speed (rpm)- 15000max rcf (g)- 21000max capacity (ml)- 4 x 175acceleration profiles- 10deceleration profiles- 10display-- multi-color lcdno of programmes- 10 (protected)timer- 30 sec to 99 min & continuous modeergonomic design and light weightsupply - 220v, 50 hz, 1 phasecan be used for extracting prp, autoclavekey features- high-pressure vessel: a high-pressure vessel designed to withstand high temperatures and pressures- temperature control: precise temperature control to ensure effective sterilization- timer and controls: easy-to-use timer and controls for convenient operation- safety features: multiple safety features, such as automatic shut-off and overheat protection, to prevent accidents and ensure safe operationconstruction and materials- stainless steel: a durable stainless steel construction to withstand high temperatures and pressures- insulation: high-quality insulation to ensure efficient heat retention and energy savings- door and seals: a secure door and seal system to prevent steam escape and ensure effective sterilizationperformance specifications- temperature range: 121 c to 134 c.- pressure range: upto 30 psi- cycle time: 15-60 minutes- sterilization capacity in liters or cubic feetsafety standards- compliance with regulations: compliance with relevant regulations, such as asme, fda, and iso standards- automatic safety devices: automatic safety devices, such as overheat protection and low-water cut off, to prevent accidents and ensure safe operation- interlocks: interlocks to prevent door opening during operation and ensure user safetyadditional features- data logging: optional data logging capabilities to track temperature, pressure, and cycle data- printed records: optional printed records of cycle data for documentation and quality control- val
Tender For supply of fixed & mobile contacttip of arno starting contactor(c118) as per s.rly drg no pd pwp 4twd.ct.001 note: material composition of silver is 90 % + -1 & nickel is10% + -1, instead of silver is 87.8% & nickel is 12.2%. [ warranty period: 30 months after the date of delivery ]
Tender For supply of set of contacttips for 3 pole 150 amp contactor as per clw specn. no.clw/es/3/0201 a lt-d or schneider make type lc1- f150 afd (per pole 02 fixed & 01 moving contact., 02 deflector.,01 bacd plate, fixing screw and washer) lc1f150 afd reference co la5 ff431a. [ warranty period: 30 months after the date of delivery ]