Get complete information related to latest Container Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Container Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Container Repair Tenders.
Tender For auction sale of disposal of spf structure and worn out components,disposal of unused, old integration tools, ms angles and fixtures,disposal of hylas payload container,shell and tube heat exchangers,150 tr frp cooling towers and 300 tr water cooled kirloskar make screw chillers,old, used, scrap water coolers,disposal of old, used, unserviceable elctrical panels,disposal of old, broken, used lt cables (10,000 kg approx),disposal of used engine oil 1200 ltr approx,disposal of tin lead stripping system,disposal of e-waste items,disposal of 325 cfm capacity screw type air compressor,disposal of old 400w hpmv light fixtures with drivers,disposal of miscellaneous scrap viz, empty containers, empty drums,etc,disposal of used, waste carton boxes,disposal of old, rusted metal bobbins,disposal of shredded papers,disposal of rotten/packing woods, glass pieces, waste rubber,etc
Tender For supply of lead acid cell,low maintenance, 2 v in hard rubber or transparent, pp-cp container con forming to irs:s-88-2004(with amdt. upto date if any). the cells should be complete with rubber boxe s( or as per specification),tubular positive plates,pasted negative plates, acid level indicating floats int er-cell connector with bolts & nuts. the cells are required to be dry & uncharged. capacity of each cell will be 200 ah at 10 hrs rate to discharge to 1.85v per cell at 27 degree centigrade.without tool ki t. [ warranty period: 30 months after the date of delivery ]
Tender For supply of lead acid cell, low maintenance, 2v in hard rubber or transparent, pp-cp container con forming to irs: s-88-2004 (with amdt. upto date if any). the cells should be complete with rubber box es ( or as per specification), tubular positive plates, pasted negative plates, acid level indicating floats inter-cell connector with bolts & nuts. the cells are required to be dry & uncharged. capacity of each c ell will be 120ah at 10 hrs rate to discharge to 1.85 v per cell at 27 degree centigrade.(without too l kit) [ warranty period: 30 months after the date of delivery ]
Tender For supply of sulphuric acid solution having nominal specific gravity 1210 or as suitable for low maintenance lead acid stationary secondary cells as per specification no. irs:s: 88/2004 or latest for s&t i nstallations : 80 ah/120 ah/ 200 ah/ 300 ah. sample should be supplied and get approved by railways befo re bulk supply. solution should be supplied in 30 liter container suitable for storage of sulphuric acid. utmo st case and necessary pre cautions must be ensured during supply and transportation by agency. note# a dvance sample to be approved by consignee before bulk supply. [ warranty period: 30 months after the date of delivery ]
Tender For supply of lead acid heavy duty traction battery (full charged) enclosed in a steel container, 30 volts 2 89 ah, two pole combine charging & running socket fitted jost part no-bktr00030288 or equivalent to suit jost make 3 wheeler battery operated platform truck. make - union, exide, luminous [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of dc lead acid or ni cd batteries for ntpc lara project - 220v lead acid or ni cd battery suitable for main plant , electrolyte for first filling plus 10percent extra in nonreturnable container , wooden racks , stand insulators , intercell, inter row, inter bank connectors , cell numbering tags with fixing arrangement 1set , anti-splash type vent plug , nickle coated connection hardware plus 5percent extra , cable clamps with fixing hardware , pvc or cfrp spill trays under battery set battery to have spill tray covering every cell , battery trolley for entire project , hydrometer , cell testing digital voltmeter 3-0-3v with testing leads , wall mounting type holder for hydrometer and thermometer , set of hydrometer syringes suitable for vent holes in different cells , thermometer for measuring electrolyte temperature , specific gravity correction chart for lead acid battery only , rubber apron , pair of rubber hand gloves , set of spanners , no smoking notice , goggles industrial , instruction card , minimum and maximum temperature indicator for each battery room , acid or alkali mixing jar , battery health monitoring system for each battey cell of battery sets as per sl.no. a.1.1 above , 220v lead acid or ni cd battery suitable for offsite area , electrolyte for first filling plus 10percent extra , ms racks properly treated with alkali resistance powder , stand insulators plus 5percent extra , intercell inter row inter bank connectors , e and c spares for battery 1 and 2 gloves , e and c spares for battery 1 and 2 vent plugs , e and c spares for battery 1 and 2 intercell connectors , supervision of erection -battery -mandays , supervision of erection -battery -visit , supervision of commissioning -battery -mandays , supervision of commissioning -battery -visit , supervision of commissioning -bhms -mandays , supervision of commissioning -bhms -visit , mandatory spares for battery 1 complete dry cell , mandatory spares for battery 1 inter-cell connectors with hardware , mandatory spares for battery 1 bhms spares , mandatory spares for battery 2 complete dry cell , mandatory spares for battery 2 inter-cell connectors with hardware
Tender For supply of lead acid low maintenance stationery secondary cell 2v, 200ah capacity at 10 hrs. rate of discharge, assembled with tubular positive and pasted negative plates in hard rubber /transparent pol ypropylene) container with microporous vent plug, lead coated inter cell connector, nuts, bolts and wash er in dry uncharged condition as per irs specification no.-s-88-2004 with latest amendments/version. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of low maintenance lead acid batteries 75 ah for electric locomotives (ppcp container) as per rdso specification no. rdsp/pe/emu/spec/0014-2000 (rev. 0) with amendment no. 1 & 2.