Web Analytics Made Easy - StatCounter

Container Terminal Tenders

Get complete information related to latest Container Terminal Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Container Terminal Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Container Terminal Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :40501320 Due date: 05 Jun, 202505 Jun, 2025 18.27 Lacs
Tender For supply, installation, testing and commissioning of 500kva ,11/0.4 kv plinth mounted distribution transformer for new laboratory of a and b block of outr, ghatikia, bhubaneswar

corporations/Associations/Others

CTN :40515137 Due date: 06 Jun, 202506 Jun, 2025 22.33 Lacs
Tender For supply, installation, testing and commissioning of 500kva ,11/0.4 kv plinth mounted distribution transformer for c and d block of outr, ghatikia, bhubaneswar

corporations/Associations/Others

CTN :40515153 Due date: 06 Jun, 202506 Jun, 2025 NA
Tender For supply, installation, testing and commissioning of 500kva, 11/0.4 kv plinth mounted distribution transformer for a and b block of outr, ghatikia, bhubaneswar

corporations/Associations/Others

CTN :40475877 Due date: 23 Jun, 202523 Jun, 2025 NA
Tender For request for expression of interest (eoi) for development of all-weather deepwater ports/ cruise terminals/ multi-purpose harbours/ ship building and repair facilities/ container terminals at the notified port limits in odisha

State Government

CTN :40486174 Due date: 06 Jun, 202506 Jun, 2025 8.93 Lacs
Location: Goa - Goa Goa - Goa
Tender For frp fencing 8 nos. - cost of material, supply and erection of frp fencing complete with gate as per specification for distribution transformer (size 4m x 3m x 2m )with concreting for frp fencing supports with plinth (0.3x0.3x0.5)cu.m x 12 nos . each ratio 1:3:6, cost of erection, supply and erection of frp fencing complete with gate as per specification for distribution transformer (size 4m x 3m x 2m )with concreting for frp fencing supports with plinth (0.3x0.3x0.5)cu.m x 12 nos . each ratio 1:3:6

CTN :40511960 Due date: 12 Jun, 202512 Jun, 2025 NA
Tender For supply of outdoor plinth mounted distribution transformer of rating 500 kva, 3-phase, 50hz , oil immersed, non-sealed type (transformer tank body and cover are bolted), primary winding in delta a nd secondary winding in star (vector symbol dyn11), onan cooled transformer, conforming to is 1180 (p art 1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in cla use 20.1 of is 1180 (par1) latest with condition that drain-cum sampling valve will be applicable for all cap acity of transformers. oil temperature indicator & winding temperature indicators (for transformers above 200kva) will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall conform to is/ iec 60137.the low voltage bushings (4 nos.) shall conform to is 7421. suitable cable-end box along with cable entry hole glands is to be provid ed as follows: a) for outdoor type: l.t. side b) for indoor type: h.t. side & l.t. side. along with following de tails: (i) kva rating of required transformer: 500kva (ii) no load voltage ratio: 6kv/415v-240v (iii) type o f mounting: plinth: (iv) the type of tap changer: off- circuit tap changer for variation of hv voltage from + 5% to -10% in steps of 2.5% (v) outdoor type (vi) energy efficiency level (latest)- 3 or higher. [ warranty p eriod: 30 months after the date of delivery ]

CTN :40511964 Due date: 12 Jun, 202512 Jun, 2025 NA
Tender For supply of outdoor type , plinth mounted, distribution transformer, minimum energy efficienc y level 3 of rating 500kva,3-phase, 11kv/415-240v, 50hz, oil immersed, non- sealed type (transformer ta nk body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (ve ctor symbol- dyn11), onan cooled transformer, conforming to is 1180 (part1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 f) of is 1180 (part 1 terminal arrangement: the transformers shall be fi tted on high voltage and low voltage sides bushing appropriate voltage and current ratings., low voltage si de cable end box required. the high voltage bushings (3nos.) shall conform to is/iec 60137. the low voltag e bushings (4 nos.) shall conform to is 7421. off-circuit tap changer (applicable for all ratings above 200 k va) for variation of hv voltage from +5% to -10% in steps of 2.5%. [ warranty period: 30 months after th e date of delivery ]

CTN :40319578 Due date: 02 Jun, 202502 Jun, 2025 18.23 Lacs
Tender For corrigendum : for running contract for hon,ble sansad nidhi/vidhayak nidhi and other deposit works under edd-budaun (semi turnkey). - cartage of following material from store center nawada, budaun to je store/je store to site of work including loading & unloading at both ends maximum distance up to 30 km., a) pcc pole 8.5 mrt long/st pole 11 mtr long., b) 11 kv xlpe cable of 3x70/3x120/3x185/3x300 sq.mm., c) 250/400 kva t/f., d) 11 kv ct/pt unit of different size, e) 11 kv jointing kit of different size, f) 11 kv pilfer proof cubical of different size, g) lt abc cable of size 1x16, 3x50, 3x95, 3x120 sq.mm., cartage of line material (11 kv pin insulator, disc insulator, stay set, cross arm, gi wire, earthing rod, ms channel, ms angle, etc) from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 30 km., cartage of 10 kva & 25 kva transformer from store centre to site of work including loading & unloading at both site, the work of safe carriage 11 kv o/g vcb store center nawada budaun to work of site distance up to 0 to 30 km including safe loading & unloading., cartage of 63 kva to 100 kva transformer from store centre to site of work including loading & unloading at both site., earthing of each 11 kv line pole & t/f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gi wire., erection of pcc pole 8.5 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., erection of stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., fabrication and fixing of all 11 kv h.t/l.t. line accessories., erection of double pole on pcc pole 8.5 mtr/stp 11 mtr. long after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories, fuse set 11 kv pin insulators and making connection properly., construction of new plinth for 250/400 kva as per uppcl norms, mounting of 250/400 kva t/f on plinth as per uppcl norms, providing and fixing wiremess fencing for 250/400 kva, erection/installation of following of vcb o/g in consumers site and cable joint of the panel to including earthing, grouting, anchor bolt of panel of making/repairing of pocket for cable to insert in panel form trench and fixing taping of busbar with wiring for ac,dc connection including providing ac and dc supply., chemical earthing for 250/400 kva t/f neutral and body complete, chemical earthing for vcb o/g, mounting of 10 & 25 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of 63 & 100 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of ct/pt unit with proper jumping of ht side and fixing of cable on lt. side of meter cubical properly, fixing of meter cubical as per uppcl norms, making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories., erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming., laying lifting stringing of proper sagging of acsr weasel/rabbit/dog conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly., laying lifting stringing of proper sagging of 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm., laying of underground 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm. sizes with open trench by brick & sand as per uppcl norms., filling the 11 kv jointing kit (joint kit providing by c

Central Government / Public Sector

CTN :40472949 Due date: 16 Jun, 202516 Jun, 2025 NA
Tender For supply of 160 kva, 11/0.416 kv, 3 phase, 50 hz, outdoor type, onan cooled, delta/star (dy n 11 group), copper wound , plinth mounted transformer with first fill of transformer oil and with standard fittings conforming to is:1180 (part-1)/2014 or latest, energy efficiency: level 2 of table 3 of amendment n o.4 2021 (details as per enclosed annexure-"a"). guranteed and other particulars as per enclosed annexur e-"b" and drawing as per enclosed annexure-"c". make: servokon or servostar or airen power or similar. [ warranty period: 30 months after the date of delivery ]

corporations/Associations/Others

CTN :40444569 Due date: 02 Jun, 202502 Jun, 2025 NA
Tender For repair of transformer (t-2 ptf) plinth at 132kv s/s khera mandir
 Loading, Please wait...

Connect us via What's Up