Get complete information related to latest Control Circuit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Control Circuit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Control Circuit Tenders.
Tender For supply of circuit breaker output battery changer battary and controlcircuit (pos no 110. 112. 112 .1) type-8, clw spec no. - clw/es/03/0050 alt - c or latest [ warranty period: 30 months after the d ate of delivery ]
Tender For dg - waluj industrial area...m and r to cwss, waluj providing photo water meter reading system through mobile application and distribution of water bills, notices and consumer services at waluj industrial area.
Tender For (a) repairing of one no neutral grounding resistor 3.3kv grade 200amp sl no htrn1569 in circuit with 3 mva 11kv /3.3 kv transformer (b) repairing of one no battery charger 415 volt /110 volt 30 amps with laying of dc , ac controlcircuit for diffe
Tender For supply of earth fault relay for auxiliary converter 415/110v ckt., harmonic filter and controlcircuit (pos no. 89.2.89.5.89.6 and 89.7) 150 ma 43 ohm 36/110v as per abb document no. hbvw 400011r 0001 and clw's specification no. clw/es/3/0090 alt-c for three phase locomotives. [ warranty perio d: 30 months after the date of delivery ]
Tender For 1. provision of alternate communication for controlcircuits/block working/other circuits like uts/prs through wireless system for various ibs location on jabalpur division of west central railway.2. balance work of enhancing of reliability by provision of high availability digital axle counter in existing 05 intermediate block signal in et-mkp section jabalpur division on west central railway
Tender For contactor with surge suppressor of lhb coaches, current rating 95 amps, ac3, voltage ratin g 690 v ac, 50/60 hz, main pole 03 nos. aux. contact 2no + 1nc, controlcircuit voltage 230 v +/-15% ac , plate & rail mounting support, standard iec/en 60947, suitable for fitment lhb coaches switch board cabi net local main supply, 1 & 2 item code s1k41, s1k42 contactor of lhb ac coaches, degree of protection ip 20, cat no. 3rt23461np304aa0+3rh29111-ha10 of siemens or lc1d1150046p7+ladn22 (230v ac) or l c1d1150046m7/m5+la4da2u (220v ac) of schneider or af116b-40 of abb or mcx 23 of l&t only. material to be supplied with oem proof of purchase & test certificate. spec: rdso spec no- rdso/pe/spec/ ac/0184-2015 (rev-1) or latest brands: siemens/schneider/abb/l&t only. [ warranty period: 12 months after the date of delivery ]
Tender For supply of earthing resistance (wire wound type) for earth fault detection controlcircuit. 100 w/390 o hm +/- 10% used in sb1 in 3-phase locomotive as per clw specn no. :- clw/es/3/0014 alt.c or latest. [ w arranty period: 30 months after the date of delivery ]
Tender For supply of circuit breaker for output battery charger and controlcircuit (pos : 110, 112.1) for wap7 & wag-9 (3 phase) class of locomotives. spec no./ drg. no- as per clw spenc. no. clw/es/3/0050 alt-c, alt/a mendt. abb id no. hbtb585501r4371. [ warranty period: 30 months after the date of delivery ]
Tender For empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint. # th
Tender For maintenance of water supply system - operation of 10mld pressure filter plant including supply of chemicals to treat raw water at cuelim, cansaulim, goa. (retender 2nd call) - operation of 10mld pressure filter plant to carryout day to day activities of treatment of raw water, with suitable man power for attending and operation of valves , suction pump, blower pump, back washing of filter bed , dosing pumps, agitating pumps, chlorine and alum dosing pumps, etc. chemical mixing with water, in chemical dosing & treating to get potable water as per who norms. keeping of all the records in respect of raw water and treated water quantity and quality aspect. recording flow meter reading , etc. complete. the plant operating man power/staff should be arranged round the clock in shift as per the directions of engineer -incharge., supply at store/site of work including transportation loading & unloading etc of alumina ferric containing 16% of al2o3 content as per is 299/2012 grade -iv packed in hdpe bags of uniform weight suitable for water treatment plant., supply at store/site of work including , transportation , loading & unloading,freight insurance etc., of sodium hypochlorite containing 6% to 8% of chlorine concentration or as required, suitable for water treatment plant, filled in hdpe can of uniform weight, including re-transporting empty hdpe cans from departmental store/site to refilling plant etc., complete.as directed by engineer in charge.