Get complete information related to latest Control Contactor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Control Contactor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Control Contactor Tenders.
Tender For corrigendum : supply of controlcontactor with 4no arrangement a , controlcontactor with 2no+ 2nc arrangeme , controlcontactors 6 amps suitable for b
Tender For corrigendum : advance e-tenders are invited for the material required for smooth running of t/wells under 08 no, 15 no. twell scheme under 502 no scheme and 05 no out of 19 no scheme of twell construction sub division no. 3 of block and distt. ropar - bch make 73 amp duros freedom series 3 pole ac controlcontactor size -g cat no ce15kn-3, l&t make 3 pole du mccb breaking capacity 180 amp cat no cm980610000, l&t make spreader terminal for du250 3 pole mccb cat no st980530000 set of 6, l&t make spare contact kit type ml-3 cat no 5595309, l&t make spare contact kit type ml-4 cat no 5595311, l&t make spare coil type ml3 cat no ss90545, l&t make spare coil type ml4 cat no ss91258, l&t make thermal overload relay type mn5 range 45-75 amp cat no ss9413700, kitkat 200 amp max, copper thimble 100 amp, copper thimble 200 amp, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 25mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 16mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 10mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 6mm2, pvc wire 7/64, pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is 694 with latest ammendment size 19/16mm, al thimble, shunt capacitor with clamp l&t make 10 kvar, shunt capacitor with clamp l&t make 12.5 kvar, shunt capacitor with clamp l&t make 15 kvar, push button l&t red, yellow, green, blue, overload relay l&t 30-50 amp, overload relay l&t 50-70 amp, overload relay l&t 40-80 amp, overload relay l&t 20-60 amp, gic timer l&t 0.1sec to 10 hrs, gic timer l&t 30 sec to 120 sec, voltmeter 0-500 volt, ammeter 0-200 amp, boparai basp-0708a single phase preventer, contactor mnx 95, spare kit mnx 95, ct voltmeter + ammeter combined, boparai overload relay 40-65 amp
Tender For corrigendum : advance e-tenders are invited for the material required for smooth running of t/wells under 52 no and 13 no out of 19 no twell scheme of garhshankar pwrmdc ltd., sub division of nurpur bedi block of distt. ropar - bch make 40 amp duros freedom series 3 pole ac controlcontactor size -g cat no ce15kn-3, bch make 40 amp duros freedom series 3 pole ac controlcontactor size -g cat no ce15kn-3 nb, bch make spare magnetic coil f series size g,j,j,kcat no mc15kw, bch make spare magnetic coil size d,e,fcat no mc15fw, bch make pneumatic timer time delay relay time range 0.05-30 sec cat no krtpn10-0 ac control, bch make pneumatic timer time delay relay time range 0.05-60 sec cat no krtpn10-1 ac control, l&t make 3 pole power contactor type ml-2 size fr-2cat no ss90701, l&t make 3 pole power contactor type ml-3 size fr-2cat no ss90721, l&t make 3 pole power contactor type ml-4 70 amp size fr 3cat no ss90910, l&t make 3 pole power contactor type mnx-32 size fr-2 cat no cs94111, l&t make 3 pole power contactor type mnx-40 size fr-2 cat no cs94190, l&t make 3 pole power contactor type mnx-50 size fr-3 cat no cs97075, l&t make 3 pole du mccb breaking capacity 100 amp cat no cm980610000, l&t make spreader terminal for du250 3 pole mccb cat no st980530000 set of 6, l&t make spare contact kit type ml-2 cat no 5595309, l&t make spare contact kit type ml-3 cat no 5595309, l&t make spare contact kit type ml-4 cat no 5595311, l&t make spare contact kit type mnx 32 cat nocs94128, l&t make spare contact kit type mnx 40 cat nocs94147, l&t make spare contact kit type mnx 50 cat nocs94150, l&t make spare coil type ml3 cat no ss90545, l&t make spare coil type ml4 cat no ss91258, l&t make thermal overload relay type mn5 range 45 75 amp cat no ss9413700j0, fuse unit gkh kit kat porcelain rewirable type conform to is2086/93 100 amp 415 volt with extension strip, fuse unit gkh kit kat porcelain rewirable type conform to is2086/93 200 amp 415 volt with extension strip, kitkat 200 amp max, copper thimble 100 amp, copper thimble 200 amp, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 4 mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 6 mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 10 mm2, pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is 694 with latest ammendment size 7/16mm, pvc wire 7/64, shunt capacitor with clamp l&t make 8.33 kvar, shunt capacitor with clamp l&t make 10 kvar, shunt capacitor with clamp l&t make 12.5 kvar, shunt capacitor with clamp l&t make 15 kvar, shunt capacitor with clamp l&t make 20 kvar, main switch on/of l&t mark 100 amp 3pole, push button l&t red, yellow, green, blue, overload relay l&t30-50- amp, overload relay l&t 28-42 amp, gic timer l&t 0.1sec to 10 hrs, gic timer l&t 0.1 sec to 120 sec, voltmeter 0-500 volt, ammeter 0-300 amp, ammeter 0-500 amp, terminal block 100 amp 3 way l&t, boparai basp-0708a single phase preventer
Tender For corrigendum : advance e-tenders are invited for material required for smooth running of t/wells under 91 no,25no,23no, 1 no out of 19 no and 41 no. scheme under 502 no deep t/well scheme of nawanshahar pwrmdc ltd.,sub division of distt. sbs nagar under bdc-1 division, ropar - bch make 110 amp duros freedom series 3 pole ac controlcontactor size -g cat no bch15mt-3-11, bch make spare magnetic coil size g,j,j,kcat no mc15kw, bch make spare magnetic coil size d,e,fcat no mc15fw, bch make ct operated overload relay range 37.6-60.0 amp cat no ct2 mc305ana3c, bch make ct operated overload relay range 56.4-90.0 amp cat no ct3mc305ana3c, bch make pneumatic timer time delay relay time range 0.05-60 sec cat no krtpn10-1 ac control, l&t make 3 pole power contactor type ml-3 size fr-2cat no ss90721, l&t make 3 pole power contactor type ml-4 70 amp size fr 3cat no ss90910, l&t make 3 pole power contactor type ml-6 size fr-3cat no ss90921, l&t make 3 pole power contactor type mnx-50 size fr-3 cat no cs97075, l&t make 3 pole du mccb breaking capacity 180 amp cat no cm980610000, l&t make spreader terminal for du250 3 pole mccb cat no st980530000 set of 6, l&t make spare contact kit type ml-3 cat no 5595309, l&t make spare contact kit type ml-4 cat no 5595311, l&t make spare contact kit type ml-6 cat no 5595313, l&t make spare contact kit type mnx 50 cat nocs94150, l&t make spare coil type ml3 cat no ss90545, l&t make spare coil type ml4 cat no ss91258, spare coil ml6 125amp, l&t make thermal overload relay type mn5 range 45-75 amp cat no ss9413700, l&t make thermal overload relay type mn5 range 66-110 amp cat no ss9413700k0, fuse unit gkh kit kat porcelain rewirable type conform to is2086/93 200 amp 415 volt with extension strip, kitkat 200 amp max, kitkat 500 amp max, copper thimble 100 amp, copper thimble 200 amp, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 25mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 16mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 10mm2, pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is 694 with latest ammendment size 19/16mm, al thimble, shunt capacitor with clamp l&t make 10 kvar, shunt capacitor with clamp l&t make 12.5 kvar, shunt capacitor with clamp l&t make 15 kvar, shunt capacitor with clamp l&t make 20 kvar, shunt capacitor with clamp l&t make 25 kvar, push button l&t red, yellow, green, blue, overload relay l&t 40-80 amp, overload relay l&t 20-60 amp, gic timer l&t 0.1sec to 10 hrs, gic timer l&t 30 sec to 120 sec, voltmeter 0-500 volt, ammeter 0-300 amp, ammeter 0-500 amp, ct voltmeter + ammeter combined, terminal block 100 amp 3 way l&t, pvc wire 7/64, control panel l&t make 50 hp, control panel l&t make 75 hp, boparai basp-0708a single phase preventer
Tender For corrigendum : advance e-tenders are invited for the material required for the smooth running of t/wells under 37 no twell scheme of tubewell construction sub division no. 4,shri anandpur sahib of block shri anandpur sahib distt. ropar - bch make 40 amp duros freedom series 3 pole ac controlcontactor size -g cat no ce15kn-3, bch make 40 amp duros freedom series 3 pole ac controlcontactor size -g cat no ce15kn-3 nb, bch make spare magnetic coil f series size g,j,j,kcat no mc15kw, bch make spare magnetic coil size d,e,fcat no mc15fw, bch make pneumatic timer time delay relay time range 0.05-30 sec cat no krtpn10-0 ac control, bch make pneumatic timer time delay relay time range 0.05-60 sec cat no krtpn10-1 ac control, l&t make 3 pole power contactor type ml-2 size fr-2cat no ss90701, l&t make 3 pole power contactor type ml-3 size fr-2cat no ss90721, l&t make 3 pole power contactor type ml-4 70 amp size fr 3cat no ss90910, l&t make 3 pole power contactor type mnx-32 size fr-2 cat no cs94111, l&t make 3 pole power contactor type mnx-40 size fr-2 cat no cs94190, l&t make 3 pole power contactor type mnx-50 size fr-3 cat no cs97075, l&t make 3 pole du mccb breaking capacity 100 amp cat no cm980610000, l&t make spreader terminal for du250 3 pole mccb cat no st980530000 set of 6, l&t make spare contact kit type ml-2 cat no 5595309, l&t make spare contact kit type ml-3 cat no 5595309, l&t make spare contact kit type ml-4 cat no 5595311, l&t make spare contact kit type mnx 32 cat nocs94128, l&t make spare contact kit type mnx 40 cat nocs94147, l&t make spare contact kit type mnx 50 cat nocs94150, l&t make spare coil type ml3 cat no ss90545, l&t make spare coil type ml4 cat no ss91258, l&t make thermal overload relay type mn5 range 45 75 amp cat no ss9413700j0, fuse unit gkh kit kat porcelain rewirable type conform to is2086/93 100 amp 415 volt without extension strip, fuse unit gkh kit kat porcelain rewirable type conform to is2086/93 100 amp 415 volt with extension strip, fuse unit gkh kit kat porcelain rewirable type conform to is2086/93 200 amp 415 volt with extension strip, kitkat 200 amp max, copper thimble 100 amp, copper thimble 200 amp, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 6 mm2, pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is 694 with latest ammendment size 7/16mm, pvc wire 7/64, shunt capacitor with clamp l&t make 8.33 kvar, shunt capacitor with clamp l&t make 10 kvar, shunt capacitor with clamp l&t make 12.5 kvar, shunt capacitor with clamp l&t make 15 kvar, shunt capacitor with clamp l&t make 20 kvar, main switch on/of l&t mark 100 amp 3pole, push button l&t red, yellow, green, blue, overload relay l&t30-50- amp, overload relay l&t 28-42 amp, gic timer l&t 0.1sec to 30 sec 12sdto, gic timer l&t 0.1 sec to 30 sec2b5dt5, voltmeter 0-500 volt, ammeter 0-300 amp, ammeter 0-500 amp, terminal block 100 amp 3 way l&t, boparai basp-0708a single phase preventer
Tender For estimate for supply and fixing of automatic street light controllers, contactors, mcbs and coin batteries to maintainence of existing ccms boxes in ward no.176- mettuguda, ward no.177 - lalapet, ward no.178- north lalaguda and ward no.179- addagutta in mettuguda circle-44,secunderabad zone, ghmc
Tender For estimate for supply and fixing of automatic street light controllers, contactors, mcbs and coin batteries to maintenance of existing ccms boxes in ward no.173- boudha nagar, ward no.173 - tarnaka, ward no.175- seethaphalmandi and ward no.176- chilkalguda in tarnaka circle-43,secunderabad zone, ghmc
Tender For estimate for suppl and fixing of automatic street light controllers, contactors, mcbs and coin batteries to maintain ence of existing ccms boxes in amberpet circle- 42,secunderabad zone, ghmc rs.1.40 lakhs
Tender For supply of incubator , laboratory centrifuge , ph meter , analytic balance , hot air oven , colorimeter , bp apparatus , entomological net , hemocytometer , dissection box , blood counting , stereo microscope , bod incubator , potassium dichromate , calcium chloride , potassium iodide , sodium thiosulphate , zinc sulphate , anti abd rh , sodium hydroxide , formic acid , isopropyl alcohol , methyl orange , ninhydrine , starch potato , sucrose , lead acetate , starch maize , hand magnifying lens , test tube , measuring jar , stirring glass rod , pipette , glass coupling jar , microscope glass slide , slide temporary permanent , measuring cylinder , blood lancet needle , petridishes , funnel , chromatography jar , insect killing jar , dropping bottle , spirit burner , chromatography paper , test tube rack , test tube holder , bunsen burner , alcohol burner , glass dropper , cotton roll , dissecting tray , dimond marker pencil , test tube brush , reagent bottle , filter paper , forceps himprincy , funnel stand holdar , watch glass , paraffin wax , insect collection net , tripod for lab , grams stain kit , slide box mocroscope slide , scissors stainless steel , mortar and pestle , stop watch , glass beaker 100ml , glass beaker 250ml , glass beaker 500ml , spatula , erlenmeyer flask conical flask 100ml , erlenmeyer flask conical flask 250ml , permanent slide , reproductive system , human skeleton model with stand , body organ , brain human , nervous system in human , excretory system in human , circulatory system in human , human skin integument , anatomy of ear , anatomy of eye , anatomy of teeth , digestive system in human , respiratory system in human , dna model watson and crick , model anatomy of heart , model anatomy of lungs , model anatomy of kidney , mitosis and meiosis , evolution horse , vernier calipers , screw gauges , stop clock , digital ) /bid number: gem/2026/b/7302727 * /dated: 03-03-2026 & & / bid document1 / 110stop watch , thermometer mercury , digital multimeter , spherometer , digital balance , digital vernier calipers , copper wire , moment of inertia , moment of inertia of fly wheel , study of a compound pendulum , bending of a beam , bending of a cantilever , y k n by searls apparatus , wire static and dynamic method , viscosity of a liquid by stokes method , stewart and gees apparatus , iquid by different method , tension by capillary rise method , liquids through capillaries , measurement of inductance , carey foster bridge , impedance at different frequencies , lcr circuit and tesponse frecquency , vibration magnetometer , magnetic field b , rc circuits , lissajous figure , network theorem , bifilar suspension , modulus of rigidity by maxwell needle , irregular bodies by inertia table , energy into heat , ketile , resistance thermometry , thermoemf thermometry , conduction of heat through poor , study of newtons law of cooling , thermal conductivity by searles method , specific heat of liquid by method of cooling , laser experimental setup with diode laser , laser experimental setup with hene laser , sonometer , mercury light , sodium light , rtelescope , ultrasonic , fresnels , polarimeter , brewsters law , optical rotation for any system , monochromatic , microscope , plancks constant using led , photoelectric effect , thompsons method , millikans method , lodine vapour , transformer core , dilectric constant , transistor , diode , zener diode , bh curve apparatus , lcr resonanee apparatus , rectifier apparatus , regulated power supply , rc coupled anmplifier , lcr impedance apparatus , cassegrain , analytical , hot plate , calorimeter digital , digital conductivity metre , ostwald viscometer glass , stalagmometer glass , centrifuge machine , desiccator 8 , measuring cylinder 100ml , petri dish plastic and glass , crucible , surgical scissors (v2) (q2)incubator, laboratory centrifuge, ph meter, analytic balance, hot air oven, colorimeter, bp apparatus, entomological net, hemocytometer with rbc a