Get complete information related to latest Control Transformer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Control Transformer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Control Transformer Tenders.
Tender For supply of overhauling & maintenance of cp transformer rectifier units , ac amp. meter, for detailed description refer price breakup sheet , ac volt meter, for detailed description refer price breakup sheet , dc volt meter, for detailed description refer price breakup sheet, dc amp. meter, for detailed description refer price breakup sheet, voltmeter ( psp meter ), for detailed description refer price breakup sheet, main rectifier diodes, iav 150 amp, piv - 1200 v , type- 150 lf 120 , "lightning arrestor( la) both input and output side, rms voltage rating - 500v ,rms current rating - 1.5 ka, type- lt 0.5 oe eqv", thyrister module (scrm) consisting two antiparrallel thyrister, for detailed description refer price breakup sheet, auxiliary transformer for control circuit power supply, for detailed description refer price breakup sheet, filter capacitor bank in dc output , 2500 micro farad , 150v x 6 electrolytic capacitors, relay for providing remote contacts for mcb tripped & ac supply fail faults , coil - 240 v ac coil resistance 10 k contacts 2no+2nc , 8 pin plug in type, relay for providing remote contacts for oil tank or instrument , chamber high temp. fault. coil - 240 v ac coil resistance 10 k contacts 3no+3nc , 11 pin plug in type, thermostate with adjustable temp. setting with nc contacts ( 30 to 110 setting ), indicator lamp , housed in 22.5 mm dia, 240 v, led type red colour, auto or manual mode selector rotary type, 4 pole , 2 way ,63 amps, 240 v, ac type srpm 5417b or pa 17463b, coarse manual output control switch , rotary type, 1 pole , 6 way ,63 amps, 240 v, ac type pa7163f, fine manual output control switch rotary type, 1 pole , 4 way ,63 amps, 240 v, ac type srpm 615dor pa 5163 d, coarse current limit settor switch cam type, 2 pole ,6 way ,6 amps, 240 v, type s6-61072, fine current limit settor switch, cam type, 2 pole ,6 way ,6 amps, 240 v, type s6-61072, reference electrode selector switch, cam type 2 pole ,4 way ,6 amps, 230 v, type s6-61070, local or remote control mode selector switch,toggle type 2 pole , 2 way ,6 amps, 240 v, , on or off toggle switches in various lamp and meter circuits. 1/2 pole , 2 way ,6 amps, 240 v, , current transformer for ammeter a1 ratio - 50/1, burden - 5 va ,class - 1, contactor 32 amp.bch make 3p +(1p no) with add on 240 v ac coil , breather ( 19.45 mm dia), output voltage setter potentiometer in local auto mode 2.5 k ohm 3 watt ww, output current setter potentiometer in local auto mode 1 k ohm 3 watt ww, oil temp. indicator range ( 0 to 150 o c ), 4-20ma converter module for dc output voltage signal input - 0-75v dc , output - 4 to 20 m a , max load - 600 ohm , accuracy - +-0.5 %, aux supply - 240 v, ac type-520 t, base or channel mounting type , 4-20ma converter module for dc output current signal input - 0-75a (75 mv) dc , output - 4 to 20 m a , max load - 600 ohm , accuracy - +-0.5 %, aux supply - 240 v, ac type-520 t, base or channel mounting type , "auto transformer with coarse and fine tappings for manual control dc of output, input -265 v , coarse taps- 7 nos. fine taps- 04 nos. capacity - 8000 va, insulation - class -a (oil cooled ) ", "main transformer with shield double wound primary- 240 +/- 10 %, secondary- (0-110 v), capacity - 10,000 va, insulation - class -a (oil cooled )", filter choke in dc output , 7.5 mh at 100 amp., control box for card fixing ceco-108 & ceco 105 d1 (and extra card connector having 40 slots), current or voltage control firing card control card , type- ceco- 105d1 , "remote control interface card control card ,type- ceco -108 ", "current limit setter card control card , type- ceco -35a- 2.5 v , 75a/75mv -33.33", "voltage current sensor card control card , type -ceco -19c ", pulse driver card ceco - 118 c, surge suppressor r-c network across scrs 75 ohm, for detailed description refer price breakup sheet, "fuse fail indicator module for diodes and output fuses six channel type with led indicators and 1 common no+nc contacts ,sensing
Tender For supply of controltransformer, type-ii, dry type, class h insulated, 200va, 750v/415v for lhb power cars and ac coaches duly fitted with 4a, 1.2kv fuses link with fuse base for primary side, duly fitted with 2a 500v fuse link with fuse base for secondary as per rdso specification rdso/pe/spec/ac/0203-2020 (rev-0) or latest and as per drawing rdso/pe/sk/ac/0223-2020 (rev-0) sheet-2.
Tender For supply of dry type air cooled controltransformer of type iv ,single phase ,100 va,750 v/110 v,ac 50hzfor the set of panels of lhb non ac hog coaches conforming to rdso/pe/spec/ac/0203-2020 (rev 0)and rdsodrawing no. rdso/pe/sk/ac/0223-2020,for said transformer only . note: one sample should got approved beforebulk supply, accepted make:ask power tech, bhasin packard, trolex, trinitron control systemabrol engineering, nacei, ramyaaelectro gear, kontactconsortium, these shall comply the specification including bom as per annexure a only. ( warranty period : upto 30 months from the date of supply)
Tender For corrigendum : construction of head race tunnels including intakes, pressure shafts, penstocks, power house cavern, transformer cum gis cavern, draft tube gate operation chamber including gate shafts, downstream surge cavern, tail race tunnels, pothead yard, adits including approach roads of kamala h.e. project (1720mw), kamle district, arunachal pradesh, (lot-2)