Get complete information related to latest Control Wiring Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Control Wiring Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Control Wiring Tenders.
Tender For work of erection of equipment, structures earthing & controlwiring for augmentation work of 100 mva to 160 mva 220/66 kv tr-1 220kv popda sub-station & 01 no. of 132/66kv feeder bay for augmentation of 132/66kv transformer no. 2 at 132kv bhestan s/s approved under r&m plan 2025-26.
Tender For erection, testing & commissioning work of 66kv equipments, structures, earthing, controlwiring, yard lighting, control-room electrification and supply of furnitures etc. at new 66kv rajpara sub-station (tal.: visavadar, dist.: junagadh) under construction division junagadh.
Tender For work of erection, commissioning of new feeder bay hv & lv equipments, testing ,earthing,controlwiring etc. of 220/66kv 160 mva transformer no.-4 new feeder bay for ehv class substation augmentation at 220 kv sagapara sub-station of am division vartej under circle amreli (under gec phase-ii)
Tender For repair/maint of diesel generator set diff cap amf panel lt panel solar water heater repair in stp anarwala repair maint solar lighting security light high mast light, fire fighting system, earthing at various water supply install at zone a b c of age em -i ge ddn
Tender For bi- annual rate contract for work of erection of 66kv equipment structures controlwiring yard lighting etc for 66kv feeder bay/66kv transformer bay/bus conversion at various sub stations under karamsad am division under nadiad circle.[under r&m plan- 2025-26].
Tender For tender for work of erection of bay equipment, cr panel, controlwiring, earthing etc at 66kv varahi sub-station under deodar division of palanpur circle
Tender For supply of 28 hp heat pump outdoor vrv or vrf , 26 hp heat pump outdoor vrv or vrf , 4 way 3. 0 tr vrf cassette indoor , 4 way 2. 0 tr vrf cassette indoor , 4 way 1. 6 tr vrf cassette indoor , 4 way 1. 3 tr vrf cassette indoor , 4 way 1. 0 tr vrf cassette indoor , 1. 6 tr vrf hi wall split indoor , 1. 0 tr vrf hi wall split indoor , 4 way 2. 0 tr 5 star cassette ac , 2. 0 tr 5 star hi wall split ac , 1. 5 tr 5 star hi wall split ac , installation of vrv or vrf outdoor , installation of vrv or vrf cassette indoor , installation of vrv or vrf split indoor , installation of cassette ac , installation of hi wall split ac , refrigerant piping 34. 9 mm , refrigerant piping 31. 8 mm , refrigerant piping 28. 6 mm , refrigerant piping 22. 2 mm , refrigerant piping 19. 1 mm , refrigerant piping 15. 9 mm , refrigerant piping 12. 7 mm , refrigerant piping 9. 5 mm , refrigerant piping 6. 4 mm , additional copper pipe for cassettre ac , additional copper pipe for split ac , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , controlwiring for cassette and split ac , cable tray , outdoor stand for vrv or vrf , outdoor stand for cable and split ac , stabiliser 5. 0 kva , stabiliser 4 kva , core cutting
Tender For work of erection of 66kv equipment, structures, controlwiring, yard lighting, control-room & electrification etc. for 2x15mva, 66/11kv rampara sub-station.
Tender For - arc of electrical material. - electrical work :, providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 10% humidity 10% to 90% rh working temp -5c to 45c . driver current 750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . led street light fixture with minimum lumen output 5600 lm, supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt-4)/ 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . 1 x 25 sq. mm. + 1x25 sq. mm. (insulated), supply and fixing of 11 kv pin insulator confirming to is:731:1971 with latest ammendment on existing bracket including all accessories like ms forged hot dipped gi pin confirming to is 2486(part-i)/1993 & is:2486 (part-ii)/1989 with latest amendment, and as per latest discom specs. etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . controlwiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . c