Get complete information related to latest Coolant Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Coolant Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Coolant Machine Tenders.
Tender For curd & paneer section expansion, modification project & additional work at panchamrut dairy, godhra on turnkey basis. - shifting of existing curd cup packing machine (capacity: 2400 cph and 3600 cph), curd matka/ tub packing machine (capacity: 120 matka/hr), semi automatic bottle packing machine pack size: 1 liter and 500 ml (capacity: 120 bpm), balance tank (200 l) with cip return pump for packing machine cip (capacity: suitable), new curd packing room with puf & aluminium partition , air curtain, al sliding door etc (capacity: as per layout), curd incubation room (capacity: as per layout), blast room for curd (capacity: as per layout), cold store for curd/paneer (capacity: 120 matka/hr), existing curd incubation room- expansion/ modification (gf) (capacity: as per layout), dismental ,shifting and re locate of existing jaw cooling system with tank,pump,chiller & pipe in pipe chiller (capacity: suitable), phe for curd milk cooling (42 to 4 degree) (capacity: 5 kl ph), curd milk transfer pump with vfd to heater (capacity: 5 kl ph), cip return pump for curd milk storage tank (capacity: 10 kl ph), curd milk heater ( 4 to 45 degree c) with all standard accessories. (capacity: 2 kl ph), steam water mixing battery with 10 mtr hose (washing points) (capacity: suitable), off line weigh scale (capacity: 120 matka/hr), paneer packing room expansion /modification with ahu system (capacity: 3 kg), paneer cube and block (100 and 200 g ) cutting machine (capacity: suitable), off line hardening block (capacity: 50kg/hr), paneer heater modification ( 4 to 80 deg.c) (capacity: suitable), paneer block cooling tank with pneumatic rack in/out system & uv treatment system with chiller and circulation pump (capacity: 2 kl), product, cip and utility pipes, valves, fittings and supports with insulation (capacity: suitable), mcc panel ,electrical and other utility (capacity: suitable), modification in existing blast room at ground floor (capacity: suitable), intruments (capacity: suitable), curd milk storage tank (capacity: 5 kl), milk storage tank for products with transfer pump (capacity: 10 kl and 10 klph pump), additon of cip circuit in existing cip kitchen (capacity: suitable), pet area incubation room one side and top insulation false ceiling with auto cut off heater including electrical connection from existing panel (capacity: suitable), installtion erection and commissioning work including lifting and shifting (capacity: suitable)
Tender For supply of spares r qty:-07 kg per cylinder , shaft seal cover, part no.- , ac926100076, make: voltas for ac plant compressor model no. 05066-5 , sh ss assly with ring, part no. , ac926101800, make: voltas for ac plant compressor model no. 05066-s , pillow block bearing for ahu of service building ac plant , cleaning chemical (copper safe) for chiller/condenser of ac plant , pillow block bearing model , ucp 205 por ahu of switch yard control room ac package , v helt a-28 , seal cover plate , p.no:ac926100076 make: -voltas for ac plant compressor model no. 05086 , shaft seal assembly , p.no:ac926101900 make: voltas for ac plant compressor model no. 05086 , charging hose 1/4" connecting (set of 3) for central ac plant , 1/4" charging nrv valve for central ac plant , liquid line filter, make-voltas for ac plant , compressor model no:05086 , v belt b 85 , v belt a-30 , liquid line filter model-165 for uniflair and blue star make package ac unit and hydrogen gas dryer unit , dryer model dcl-083. code 02325005 for blue star make package ac.5.5 ton. , tyre element for fenner make f-80 tyre coupling , refrigeration oil charging pump suitable for voltas make ac plant compressor model no. 05086 , connecting valve for refrigeration oil charging pump suitable for voltas make ac plant compressor model no. 05086 , 3-way manifold gauge set with 3 charging hoses for r22, r134a, r407c for central ac plant , gas cylinder valve spindle key , gas cylinder adaptor for r-22 gas cylinder , gas cylinder adaptor for n2 gas cylinder , air cooled condenser model , no: dobss. capacity: 8.5 tr, make: voltas por 132kv switch yard control room ac package , pedstal bearing size-ucp209d1 for cooling tower of contol room ac plant , brass float valve size: 20 mm (3/477) , ratchet wrench (4 size: 1/2-inch hex, 9/16-inch hex and 1/4-inch square, 3/16-inch square) , fenner make v belt size b-90
Tender For corrigendum : replacement of em items against ber held with ge i rnd east bangalore - supply, installation, testing & commissioning of double skin horizontal air handling unit of fully capacity, complete with double skin insulated with cfc free foam (puf) panels of 25mm thick, 42 kg/cum density. sandwitched between 0.6 mm thick g.i. sheets. outer skin shall be pre coated g.i. sheet pre coated off white. ahu frame works shall be of pre cast vertical and horizontal extruded aluminium profile with three way corner frame sections. frame construction should bear the load of structure and load of the frame structure shall be uniformly distributed along the entire housing of the ahu. food grade self adhesive coated neoprene gasket to be provided between panels and structure of the ahu to ensure the entire housing is airtight., backward curved blower to be supplied along with motor (kruger/nicotra). filter will be of 10 mic as pre filter, 3 mic as fine filter. cfm as below with 60-80mm sp complete all as specified and directed., note: rate quoted to be deemed to include civil works for hvac like breaking and opening for entry and exit of supply ducts from ahu room, exhaust ducts into shafts for exiting copper pipes / drain pipes also. fire rated material of 25mm thick phenotherm to be used near civil closures for fire resistant properties., a) 13200 cfm, 60mm static ahu capacity 33 tr., 11 tr dx outdoor ac unit complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a minimum capacity.note: rate quoted to be deemed to erection of condenser unit platform (ms angle frame with 02 coats of red-oxide and 01 coat of enamel black paint) with ms works for duct support., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 22 tr ducted packaged ac unit with 8800cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 11 tr ducted packaged ac unit with 4400cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 8.5 tr ducted packaged ac unit with 3500cfm complete all as specified and directed., supply, installation, testing & commissioning of air cooled ducted split air conditioners of capacity 8.5 tr with r2 series: r 407c eco friendly refrigerant, nominal cooling capacity 1,02,000 btu/hr, nominal air flow 3400 cfm, microprocessor based with lcd display controller and hermetically sealed scroll type compressor, all necessary connections with suitable size of copper cables and initial gas charging, provision of necessary pcc platform / iron angle frame for outdoor unit complete all as specified and directed by engineer-in-charge., dismantling / taking down / transporting carefully old acs outdoor & indoor unit with all connected acessories and to be deposited in mes store complete all as specified and directed., dismantling / taking down / transporting carefully old unserviceable ducting items off any size and capacity with all connected accessories and to
Tender For construction of room and installation of water cooling machine in ward no-33 near mohini mill gate, ghola road bazar under kamarhati municipality
Tender For supply of set of duct assemblies for tmb/ocb/mrb as per clw drg.nos. set consists of 03 items of 14 nos. setdetails as follows. 1) scavenger duct assembly (oil cooling ventilation) as per clw drg.no.1209-11.144-037 alt.2.-06 nos. 2) duct bend assembly (machine room ventilation) as per clw drg. no 1209.11.244-035 alt.1.-04 nos. 3)filter duct assembly (traction motor ventilation) as per clw drg.no.1209-11.139-033 alt.4.-04 nos.
Tender For construction of room and installation of water cooling machine in ward no-33 near mohini mill gate, ghola road bazar under kamarhati municipality
Tender For provn of deficient ceiling fans exhaust fans internal wiring and cooling appliances at ee hall room and various messes swivel lights at watch towers flame proof light and exhaust fans at mt pol store and light facility at mt test point and brazin